• Title/Summary/Keyword: disk-type

Search Result 927, Processing Time 0.023 seconds

A Study on Tribological Characteristics of DLC Films Considering Hardness of Mating Materials (상대 재료의 경도를 고려한 DLC필름의 트라이볼로지 특성)

  • Na, Byeong-Cheol;Tanaka, Akihiro
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.260-266
    • /
    • 2002
  • DLC films were deposited on Si wafer by RF plasma assisted CVD using CH4 gas. Tribological tests were conducted using rotating type ball on disk friction tester in dry air. Four kinds of mating balls were used. The mating balls were made with stainless steel but apply different annealing conditions to achieve different hardness conditions. Testing results in all load conditions showed that the harder the mating materials, the lower the friction coefficient among the three kind of martensite mating balls. In case of austenite balls, the friction coefficients were lower than fully annealed martensite ball. The high friction coefficient in soft martensite balls seems to be caused by the larger contact area between DLC film and ball. The wear tracks of DLC films and mating balls could have proven that effect. Measuring the wear track of both DLC films and mating balls have similar tendency comparing to the results of friction coefficients. Wear rate of austenite balls were also smaller than that of fully annealed martensite ball. The results of effect of applying load showed, the friction coefficients were become decrease when the applying loads exceed critical load conditions. The wear track of mating balls showed that some material transfer occurs from DLC film to mating ball during the high friction process. Raman spectra analysis showed that transferred material was a kind of graphite and contact surface of DLC film seems to undergo phase transition from carbon to graphite during the high friction process.

Design of an Efficient Parallel High-Dimensional Index Structure (효율적인 병렬 고차원 색인구조 설계)

  • Park, Chun-Seo;Song, Seok-Il;Sin, Jae-Ryong;Yu, Jae-Su
    • Journal of KIISE:Databases
    • /
    • v.29 no.1
    • /
    • pp.58-71
    • /
    • 2002
  • Generally, multi-dimensional data such as image and spatial data require large amount of storage space. There is a limit to store and manage those large amount of data in single workstation. If we manage the data on parallel computing environment which is being actively researched these days, we can get highly improved performance. In this paper, we propose a parallel high-dimensional index structure that exploits the parallelism of the parallel computing environment. The proposed index structure is nP(processor)-n$\times$mD(disk) architecture which is the hybrid type of nP-nD and lP-nD. Its node structure increases fan-out and reduces the height of a index tree. Also, A range search algorithm that maximizes I/O parallelism is devised, and it is applied to K-nearest neighbor queries. Through various experiments, it is shown that the proposed method outperforms other parallel index structures.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Study on Tribological Characteristics of Machine Component in Boundary Lubrication (경계윤활에서 기계 부품 소재의 트라이볼로지적 특성에 관한 연구)

  • Kim, Myeong-Gu;Seo, Kuk-Jin;Nam, Jahyun;Kim, Dae-Eun
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.356-361
    • /
    • 2019
  • The friction and wear between machine components directly influence the energy loss and failure in various machines. Therefore, there is always a demand for finding methods to reduce friction and wear. Of the possible methods, lubrication is a widely used method for reducing friction and wear. In the case of lubrication, it is important to analyze the tribological behavior in the boundary lubrication because most of friction and wear occurs in the boundary lubrication regime. Cast iron has been regarded as a good material for industrial applications due to the excellent mechanical properties and high productivity. Especially, nodular cast iron is a material that shows better mechanical properties and wear-resistance compared with cast iron due to inclusion of spheroidal graphite. In this work, we investigated the tribological characteristics of nodular cast iron with respect to different counter parts in boundary lubrication regime. Sliding tests were conducted with SUJ2, ZrO2, Si3N4 balls as counter parts using a pin-on-disk type tribotester. The results showed different friction and wear behaviors with different counter parts. The case of ZrO2 showed the lowest wear rate in specimen and no significant ball wear. In case of SUJ2, it showed similar wear rate with ZrO2 case in specimen and the highest friction coefficient. The case of Si3N4 showed the lowest friction coefficient, 33% lower than the case of SUJ2. It showed 16.9 times larger wear rate in specimen and 43% larger wear rate in ball compared to that of the SUJ2 case.

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

Patterns of Antimicrobial Resistance and Genotyping of Carbapenemase-producing Imipenem-nonsusceptible Pseudomonas aeruginosa (Imipenem 비감수성 Carbapenemase 생성 Pseudomonas aeruginosa에 의한 항생제 내성유형과 분자생물학적인 특성)

  • Lee, Jin-Hee;Lee, Gyusang;Lim, Kwanhun;Eom, Yong-Bin;Kim, Shin-Moo;Kim, Jong-Bae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.2
    • /
    • pp.71-80
    • /
    • 2010
  • Pseudomonas aeruginosa are important nosocomial pathogens. Their resistance to carbapenem is increasing and causing concerns in Korea. An increasing prevalence of carbapenem resistance mediated by acquired carbapenemase is being reported. Over a 10 month-period from July 2007 to April 2008, 32 strains of imipenem-nonsusceptible P. auruginosa were isolated from Kangwon National University Hospital. To determine the prevalence and genotypes of the carbapenemase-producing clinical isolates, the antibiotic susceptibility was determined by Microscan Walkaway 96 SI System and the carbapenem activity was detected by the modified Hodge test and the imipenem-EDTA-SMA double-disk synergy test. The metallo-${\beta}$-lactamase gene and OXA-type ${\beta}$-lactamase gene reported in Korea were detected by PCR. As for the result of PCR, 30 isolates of P. aeruginosa were found to have $bla_{IMP-1}$-like and 1 isolate was found to have $bla_{IMP-1}$-like and $bla_{IMP-2}$. No clinical isolates were found to have $bla_{SIM-1}$, $bla_{OXA-23}$-like and $bla_{OXA-24}$-like. Random amplified polymorphic DNA (RAPD)-PCR and dendrogram for genetical similarity to band patterns of each clinical isolates were examined. P. aeruginosa were grouped into 7 clusters of up to 50% of similarity index. In the P. aeruginosa group, PS3 was resistant to the most antibiotics, PS1 was susceptible to the most antibiotics. PS7 was resistant to aztreonam unlike other groups. This is the first report of prevalence of carbapenemase in Chuncheon.

  • PDF

A Study of the Improvement in an Anaerobic Digester for Sludge Reduction (슬러지 저감을 위한 혐기성 소화조 개선에 관한 연구)

  • Kim, Hong-Seok;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.516-522
    • /
    • 2011
  • The largest problem of domestic anaerobic digestion is low digestion efficiency. Reasons of the problem would be low organic matters input, low mixing efficiency in digestion tank, refractory excess sludge etc.. In this study, screw attached disk-type concentration system and a mechanical mixing system, solubilization facility improvements were performed to solve problems. Through these improvements, the sludge conc. of the concentrator increased 2.6-fold and the volume reduction efficiency was increased 3.0-fold. In addition, the dead-space is reduced by mechanical agitation. Anaerobic digester gas production in the digestion tank is increased from $193.8m^3$ to $386.0m^3$ per day. Digestion efficiency is improved to 54.6% from 47.6%. Digestion gas production is increased from $0.30Nm^3/kg$ VS to $0.42Nm^3/kg$ VS.

Effect of Kinematic Motion on Changes in Coefficients of Friction of Porcine Knee Joint Cartilage (기구학적 운동이 돼지 무릎 관절연골의 마찰계수 변화에 미치는 영향)

  • Kim, Hwan;Kim, ChoongYeon;Lee, KwonYong;Kim, DaeJoon;Kim, DoHyung
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.46-50
    • /
    • 2013
  • In this study, the frictional behaviors of articular cartilage against a Co-Cr alloy in two types of kinematic motions were compared. Cartilage pins were punched from the femoral condyles of porcine knee joints, and Co-Cr alloy disks were machined from orthopedic-grade rods and polished to a surface roughness ($R_a$) of 0.002. Friction tests were conducted by using a pin-on-disk-type tribotester in phosphate buffered saline (PBS) under pressures of 0.5, 1, and 2 MPa. All tests were performed in the repeat pass rotational (ROT) and the linear reciprocal (RCP) sliding motions with the same sliding distance and speed of 50 mm/s. The coefficients of friction of the cartilage against the Co-Cr alloy increased with the sliding time in both kinematic motions for all contact pressures. The maximum coefficients of friction in RCP motion were 1.08, 2.82, and 1.96 times those in ROT motion for contact pressures of 0.5, 1, and 2 MPa, respectively. As the contact pressure increased, the coefficients of friction gradually increased in RCP motion, whereas they decrease and then increased in ROT motion. The interaction between the directional change of the shear stress and the orientation of collagen fiber in the superficial layer of the cartilage could affect the change in the frictional behaviors of the cartilage. A large difference in the coefficients of friction between the two kinematic motions could be interpreted as differences in the directional change of shear stress at the contact surface.

Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs (LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성)

  • Nam, Young-Mi;Chung, Woon-Hyuk;Lee, Dae-Won;Kim, Hyun-Ja;Kim, Gi-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.135-141
    • /
    • 1997
  • The study of anneal characteristics is important for TL dosimeter to reuse. To obtain the annealing condition of the recently developed, new TL dosimeter, LiF:Mg,Cu,Na,Si Teflon Tills in a disk type (diameter 4.5 mm, thickness about $90mg/cm^2$), we studied for pre-irradiation annealing, readout procedure and post-readout annealing, in order. The gamma irradiations were carried out with a $^{60}Co$, dose of 0.1 Gy. We have used the method that observe the variation of thermoluminescent(TL) intensity of these Teflon TLDs over repeated cycles by changing both anneal temperature and anneal time with the TLD reader and the oven. There is a 5% loss in sensitivity over the ten repeated readouts by the annealing condition:pre-irradiation annealing at $80^{\circ}C$ for one hour, readout to $280^{\circ}C$ and post-readout annealing at $270^{\circ}C$ for 20 seconds.

  • PDF

A study of the synthesis and the properties on microwave dielectric material of $BaO-Sm_2O_3-TiO_2$ system ($BaO-Sm_2O3-TiO_2$계 마이크로파 유전체의 합성 및 그 특성에 관한 연구)

  • 이용석;김준수;이병하
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.274-283
    • /
    • 1997
  • These days, according to surprising development of communication enterprises, every soft of devices is getting smaller and cheaper. Among these Devices, microwave dielectric ceramics are studied and progressed briskly as the materials of dielectric resonator. Dielectric properties of BaO-S $M_{2}$ $O_{3}$-Ti $O_{2}$, one of the BaO Lnsub 2/ $O_{3}$-Ti $O_{2}$ (Ln=La, Sm, Nd, Pr…) system, synthesized by solid-reaction and coprecipitation method were investigated. Disk-type samples were sintered at 1250-1400.deg. C for 2hrs. As a result, single phase was not synthesized in both method. First created the second phase of S $M_{2}$ $Ti_{2}$ $O_{7}$, and then the last phase of $Ba_{3.75}$S $m_{9.5}$ $Ti_{18}$ $O_{54}$, Ti $O_{2}$, and $Ba_{2}$ $Ti_{9}$ $O_{20}$. When the sample was sintered at 1280.deg. C (in solid reaction method) and at 1310.deg. C (in coprecipitation method), it obtained highest dielectric constant (72.96 and 71.70, respectively) and high Q value. Above that temperature, dielectric constant and Q value decreased because of lattice defect according to oxygen vacancies........

  • PDF