• 제목/요약/키워드: disinfection

검색결과 946건 처리시간 0.023초

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

  • Nirale, Rutuja Madhukarrao;Thombre, Ram;Kubasad, Girish
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.24-29
    • /
    • 2012
  • PURPOSE. To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n =20). Data were analyzed using student paired 't'and unpaired 't'test. RESULTS. Microwave disinfection produces significant shrinkage in both denture bases without relining (t =17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION. Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

클라우드 기반 O2O 소독 서비스 시스템 설계 및 구현 (Design and Implementation on Cloud-based System for O2O Disinfection Services)

  • 장예진;백종호
    • 인터넷정보학회논문지
    • /
    • 제25권1호
    • /
    • pp.39-48
    • /
    • 2024
  • 코로나19의 발생으로 인한 방역 및 소독업무의 중요성이 높아짐에 따라 소독원을 모집하고 싶은 소독사업자와 일하고 싶은 소독원의 수요가 증가했지만, 구인·구직은 쉽지 않은 실정이며, 소독 업무에 대한 자동화와 업무를 효율적으로 관리할 수 있는 시스템이 필요하다. 따라서 본 논문에서는 O2O 소독 서비스 시스템을 MVC 패턴을 사용하여 설계하고, MySQL, Ejs/BootStrap 뷰, Node.js를 통해 구현한다. 또한, AWS 클라우드 서비스와 연동하여 사용자가 언제 어디서나 시스템을 사용할 수 있게 한다. 제안한 O2O 소독 서비스 시스템을 통해 국내 소독방역 시장의 인력 채용의 어려움을 해결하고, 기존의 비효율적인 소독 업무 프로세스 개선을 기대한다.

자외선 소독기 성능 예측을 위한 CFD 해석 기법 연구 (A Study on CFD Methodology of the Performance Predictionfor the UV Disinfection Reactor)

  • 김현수;박정규;이경혁;조진수
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.44-51
    • /
    • 2014
  • The disinfection method using UV has emerged as photodissociation in water disinfection. In order to predict performance for UV disinfection, CFD analysis was performed due to saving cost. Most CFD studies of UV reactor have used particle tracking method. However it demands additional analysis time, computing resource and phase besides working fluid. In this paper, pathogenic microorganisms' route is assumed to streamline of fluid to save computing time. the computational results are in good agreement with experimental results. The results of streamline method are compared with the particle tracking method. In conclusion, the effectiveness of streamline method for UV disinfection are confirmed.

비정돈 환경의 표면 소독을 위한 실현성 예측 기반의 장애물 제거 계획법 및 접촉식 방역 로봇 시스템 (Feasibility Prediction-Based Obstacle Removal Planning and Contactable Disinfection Robot System for Surface Disinfection in an Untidy Environment)

  • 강준수;이인제;정완균;김기훈
    • 로봇학회논문지
    • /
    • 제16권3호
    • /
    • pp.283-290
    • /
    • 2021
  • We propose a task and motion planning algorithm for clearing obstacles and wiping surfaces, which is essential for surface disinfection during the pathogen disinfection process. The proposed task and motion planning algorithm determines task parameters such as grasping pose and placement location during the planning process without using pre-specified or discretized values. Furthermore, to quickly inspect many unit motions, we propose a motion feasibility prediction algorithm consisting of collision checking and an SVM model for inverse mechanics and self-collision prediction. Planning time analysis shows that the feasibility prediction algorithm can significantly increase the planning speed and success rates in situations with multiple obstacles. Finally, we implemented a hierarchical control scheme to enable wiping motion while following a planner-generated joint trajectory. We verified our planning and control framework by conducted an obstacle-clearing and surface wiping experiment in a simulated disinfection environment.

돼지 운송 차량과 운전자에 대한 도축장에서의 세척 및 소독 과정에 대한 고찰 (A study of washing and disinfection process for pig transport vehicles and drivers in abattoirs)

  • 김환주;김승채;정창기;김재엽;김재홍;백예찬;정용진;김원일
    • 한국동물위생학회지
    • /
    • 제44권1호
    • /
    • pp.51-59
    • /
    • 2021
  • Various infectious diseases have threatened swine industries in Korea. One of the major risk factors of disease spread is livestock transport vehicle. For this reason, all abattoirs are required by law to have vehicle washing and disinfection facilities. However, detailed guidelines for cleaning and disinfection procedures were not provided. So in this study, assessment by visual observation was conducted to evaluate how well the cleaning and disinfection procedures of livestock transport vehicles have been performed in four different abattoirs in Jeonbuk, Korea. The observation included length of car washing time, the number of washing bay, type of washperson, type of disinfectant application, length of disinfection time, and compliance of driver's hygienic procedure. Every vehicle in all abattoirs conducted washing and disinfection procedure. However, there were procedural differences for each abattoirs and defects in the washing and disinfection procedures. In addition to that, the compliance of driver's hygienic procedure was not sufficient. Hence, detailed manuals on washing and disinfection procedures for involved people are required and it is necessary to establish an inspection and evaluation system.

혈액투석 혈관통로 소독에 있어 클로르헥시딘의 효과 (The Efficacy of Chlorhexidine in Hemodialysis Vascular Access Device Disinfection)

  • 양지현;유영미;유민경;문성미;박수진
    • 한국의료질향상학회지
    • /
    • 제23권1호
    • /
    • pp.55-67
    • /
    • 2017
  • Purpose:The purpose of this study was to apply the disinfection method using chlorhexidine in practice on disinfection of vascular access for hemodialysis. Methods: This study was designed as a randomized controlled trial for examining effectiveness on infection of the vascular access device for hemodialysis when using chlorhexidine and betadine/alcohol. One-hundred-thirty study participants were separated into two groups randomly. Infection signs of the vascular access device for hemodialysis were observed and recorded before disinfection on vascular access device. Result: Before the study, there was no difference between the experimental group (chlorhexidine group) and the control group (betadine/alcohol group) in general characteristics and hematological index. Incidence of infection rate of chlorhexidine group was 0 percent and the betadine/alcohol group was 1.5 percent. There was no significant difference between the two groups. Conclusion: This study examined the effectiveness of prevention of infection with the disinfection method using chlorhexidine and betadine/alcohol. The disinfection method using chlorhexidine is considered an effective and alternative method of betadine/alcohol.

와동 발생기를 이용한 자외선 살균 시스템 성능 향상에 관한 연구 (A Study on Enhancement of UV Disinfection System Performance by the Vortex Generator)

  • 김봉환;안국찬;김동진
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.24-29
    • /
    • 2007
  • The effectiveness of a UV(ultra violet) disinfection system depends on the characteristics of the waste water, flow conditions, the intensity of UV radiation, the amount of time the microorganisms are exposed to the radiation, and the reactor configuration. The wast water flow conditions are important factors in the design of UV disinfection system from the point of enhancement view of UV disinfection. The turbulent energy intensity in the wake by the vortex shedding are effective for UV radiation. Therewith the effectiveness of vortex generator is considered as a enhancement of UV disinfection. The experimental results presented give important evidences and explain that it is possible to predict UV disinfection performance based on flow experiments. An experimental investigation of two types of the vortex generator is presented. The qualitative and quantitative evaluations of the wake are made by flow visualization using smoke wire method and the measurement of vortex frequencies in the wind tunnel. From the experiment, following results were obtained that the delta wing type vortex generator is more effective than circular type because of the higher vortex frequencies and the smaller drag.

전기분해수 살균효과 및 소독부산물 생성 특성 평가 (Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water)

  • 조영만
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

Disinfection of various materials with 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride in hatchery facilities

  • Kim, Yu-Jin;Kim, Jun-Beom;Song, Chang-Seon;Nahm, Sang-Soep
    • Animal Bioscience
    • /
    • 제35권4호
    • /
    • pp.631-637
    • /
    • 2022
  • Objective: Surface disinfection is important in the proper running of livestock farms. However, disinfection of farm equipment and facilities is difficult because they are made of different materials, besides having large surface areas and complex structures. 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride (Si-QAC) is a quaternary ammonium salt-based disinfectant that attaches to various surfaces by forming covalent bonds and maintains its disinfecting capacity for a considerable time. Our aim was to evaluate the potential use of Si-QAC for disinfection of farm equipment and facilities. Methods: The short- and long-term antimicrobial and antiviral effects of Si-QAC were evaluated in both laboratory and farm settings using modified quantitative assessment method based on the standard operating procedures of the United States Environmental Protection Agency. Results: Si-QAC was highly effective in controlling the growth of the Newcastle disease virus and avian pathogenic Escherichia coli. Electron microscopy revealed that the mechanism underlying the disinfection activity of Si-QAC was associated with its ability to damage the outer membrane of the pathogen cells. In the field test, Si-QAC effectively reduced viral contamination of surfaces of equipment and space. Conclusion: Our results suggest that Si-QAC has great potential as an effective chemical for disinfecting farm equipment and facilities. This disinfectant could retain its disinfection ability longer than other commercial disinfectants and contribute to better farm biosecurity.

콘택트렌즈 관리용품의 살균력 효능 검사법 비교 (Comparison of Evaluation Methods for Disinfection Efficacy of Contact Lens Care Products)

  • 성형경;변현영;김소라;박미정
    • 한국안광학회지
    • /
    • 제19권1호
    • /
    • pp.59-67
    • /
    • 2014
  • 목적: 콘택트렌즈 관리용품의 살균력 효능 검사법 기준 개발을 위하여 막여과법(Membrane filtration method)과 희석중화법(Dilution-neutralization method)의 살균력 검사 결과를 비교하고 시판되고 있는 콘택트렌즈 관리용품의 살균력을 제시하고자 하였다. 방법: 포도상구균(Staphylococcus aureus), 녹농균(Pseudomonas aeruginosa), 세라티아균(Serratia marces cens), 칸디다균(Candida albicans)을 대상으로 하여 FDA(Food and Drug Administration)기준인 막여과법과 식품의약품안전처에서 새롭게 가이드라인으로 제시할 희석중화법의 살균력 효능 결과를 비교하였으며 총 20종 다목적 용액의 살균력을 측정하였다. 결과: 살균효과가 강한 살균 성분 및 관리용품의 효능은 막여과법과 희석중화법 모두 동일한 결과를 나타냈다. 살균효과가 약한 관리용품의 경우는 막여과법 검사시에는 균이 뭉쳐있어 정확한 균 수 측정이 불가능하였으나 희석중화법 검사시는 정확한 균 수 측정이 가능해짐을 확인하였다. 또한 시판되고 있는 관리용품 중에는 살균력 기준을 통과하지 못한 제품이 존재하였으며 특히 세라티아균과 칸디다균에 대한 살균력이 약한 경우가 많았다. 결론: 막여과법에 비해 희석중화법이 소량의 샘플로 더 정확하게 균수를 측정하는 것이 가능하며 결과 확인이 빨라 살균력 효능 검사시 유용하게 사용될 수 있음을 알 수 있었다.