• Title/Summary/Keyword: discharge-supply system

Search Result 230, Processing Time 0.03 seconds

Determination of an Optimum Orbiting Radius for an Oil-Less Scroll Air Compressor

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kwon, Tae-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.4
    • /
    • pp.124-129
    • /
    • 2008
  • Design practice has been made on an oil-less scroll air compressor as an air supply device for a 2 kW fuel cell system where air pressure of 2 bar and flow rate of 120 liter/min are required. Basic structure of the scroll compressor includes double-sided scroll wrap for the orbiting scroll driven by two crankshafts connected to each other by a timing belt. These features can eliminate thrust surface which otherwise would produce frictional heat and jeopardize reliable operation of the orbiting scroll and the scroll element's deformation as well. This study focuses on optimum scroll wrap design; orbiting radius has been chosen as an independent design parameter. As the orbiting radius changes, scroll sizes such as scroll base plate and discharge port diameters change accordingly. Gas compression-related losses and mechanical loss also change with the orbiting radius. With a scroll base plate diameter of 120mm at most and discharge port of at least 10mm, the orbiting radius should be within the range of 2.5-4.0mm. With this range of the orbiting radius, it was estimated by performance analysis that the compressor efficiency reached to a maximum of ${\eta}_c$=96% at the orbiting radius of $r_s$=3.5mm for the scroll wrap height-to-thickness ratio of h/t=5.

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

Study on operation characteristics of the cold air distribution systems with an ice storage tank (빙축열을 이용한 저온공조시스템 운전 특성 연구)

  • 염한길;박병규;고득용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

Hydrologic Modeling for Agricultural Reservoir Watersheds Using the COMFARM (COMFARM을 이용한 농업용저수지 유역 수문 모델링)

  • Song, Jung-Hun;Park, Jihoon;Kim, Kyeung;Ryu, Jeong Hoon;Jun, Sang Min;Kim, Jin-Taek;Jang, Taeil;Song, Inhong;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • The component-based modeling framework for agricultural water-resources management (COMFARM) is a user-friendly, highly interoperable, lightweight modeling framework that supports the development of watershed-specific domain components. The objective of this study was to evaluate the suitability of the COMFARM for the design and creation of a component-based modeling system of agricultural reservoir watersheds. A case study that focused on a particular modeling system was conducted on a watershed that includes the Daehwa and Dangwol serial irrigation reservoirs. The hydrologic modeling system for the study area was constructed with linkable components, including the modified Tank, an agricultural water supply and drainage model, and a reservoir water balance model. The model parameters were each calibrated for two years, based on observed reservoir water levels. The simulated results were in good agreement with the observed data. In addition, the applicability of the COMFARM was evaluated for regions where reservoir outflows, including not only spillway release but also return flow by irrigation water supply, substantially affect the downstream river discharge. The COMFARM could help to develop effective water-management measures by allowing the construction of a modeling system and evaluation of multiple operational scenarios customized for a specific watershed.

Monitoring System of AtoN Charge and Discharge Controller (항로표지 충·방전조절기의 모니터링 시스템)

  • Ye, Seong-hyeon;Han, Soonhee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.639-642
    • /
    • 2014
  • If the power of the general is not supplied, Visual aids utilize solar power system. The power supply system of these, the role of the power regulator to manage the charging and discharging is very important. In recent years, by introducing the IT technology for the effective management of visual aids, it was supposed to add a device that uses the power consumption. Thus, the importance of power regulator has increased. Currently, the power regulator is installed inside the AtoN, if the accessibility is not ensured, there is a difficulty that can not be checked. In order to solve these problems, in this paper, you have installed the Blue-tooth module to the power regulator. Also, by using the Blue-tooth communication function of a smart phone, a radio check has implemented a possible monitoring system. Advantage of the system implemented is a simple configuration and low installation cost. Also, it is possible to check the state information of the real-time power supply regulator. In addition, it has the effect of preventing accidents and reducing costs of inspection.

  • PDF

Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season (강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

Gird Connected Modeling of Primary Frequency Recovery Reserve Provided by Electric Vehicle Considering Characteristics of Electric Vehicle Charge/Discharge Control Integrated Environment (전기자동차 충·방전제어 통합 환경을 고려한 전기차 1차 주파수 회복예비력의 계통연계형 모델링)

  • Kook, Kyung Soo;Lee, Jihoon;Moon, Jonghee;Choi, Wooyeong;Park, Kijun;Jang, Dongsik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.249-254
    • /
    • 2021
  • As the spreading speed of electric vehicles increases rapidly, those are expected to be able to use them as flexible resources in the power system beyond the concern for the supply of its charging power. Especially when the Renewable Energy sources (RES) which have no intrinsic control capability have replaced the synchronous generators more and more, the power system needs to secure the additional frequency control resources to ensure its stability. However, the feasibility of using electric vehicles as the frequency control resources should be analyzed from the perspective of the power system operation and it requires the existing simulation frameworks for the power system. Therefore, this paper proposes the grid connected modeling of the primary frequency control provided by electric vehicles which can be integrated into the existing power system model. In addition, the proposed model is implemented considering technical performances constrained by the characteristics of the Vehicle-Grid Integration (VGI) system so that the simulation results can be accepted by the power utilities operating the power system conservatively.

Development of Rehabilitation and Management Techniques for Old Water Distribution Systems (기존 상수도 노후관망의 개량 및 관리 기법의 개발)

  • 김중훈;김종우
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.197-205
    • /
    • 1996
  • Flow carrying capacity of water distribution systems is getting reduced by deterioration of pipes in the systems. The objective of this study is to develop a managerial decision-making model for the rehabilitation of water distribution systems with a minimum cost. The decisions made by the model also satisfy the requirements for the discharge and pressure at demanding nodes in the system. The replacement cost, pipe break repair cost, and pumping cost are considered in the economic evaluation of the decision along with the break ratio and interest ratio to determine the optimal replacement time for each pipe. Then, the hydraulic integrity of the water distribution system is checked for the decision by a pipe network simulator, KYPIPE, if the discharge and pressure requirements, the decision made for the optimal replacement time is revised until the requirements are satisfied. The model is applied to an existing water distribution system, the Metropolita Water Supply Project (1st Phase). The result shows that the decisions for the replacement time determined by the economix analysis are accepted as optimal and the hydraulic integrity of the system is in good condition.

  • PDF