• Title/Summary/Keyword: discharge flow

Search Result 2,053, Processing Time 0.031 seconds

Flow Structure Interaction 3-D Reciprocating Compressor and Impact Analyses of Compressor Discharge Valve (압축기 토출벨브의 유체-구조 연계해석 및 충돌해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Park, Kang-Gyun;Jung, Won-Hyun;Ahn, Jae-Woo;Moon, Kyeong-Ho;Ko, Young-Pil;Kim, Hyeong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.633-640
    • /
    • 2007
  • In this paper, 3-D reciprocating compressor is taken into flow-structure interaction analysis. The full cycle process consisted of cylinder expansion and compression has been modeled without considering flow leakage through cylinder wall. Fully-coupled FSI analysis of this compressor model was iteratively solved and gives sufficient result with the experimental test. The study is emphasized to thoroughly investigate discharge valve motion, opening and closing, in order to determine discharge valve region which is prone to have high effective stress. The cylinder pressure is successfully validated before conducting impact analyses between discharge valve and other susceptible supported structure. Velocity profile has been obtained in FSI analysis is used as initial condition to carry out further impact analyses. Stress result of discharge valve and valve spring gives preliminary estimation of higher stress area due to its impact phenomena.

  • PDF

ExPerimental Study on the Determination of Discharge Coefficients in Tide Gates (배수갑문의 유량계수 결정에 대한 실험적 연구)

  • 권순국;나정우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.1
    • /
    • pp.51-59
    • /
    • 1986
  • Through the hydraulic model test, a more convenient and accurate method of deter- mining discharge coefficients in the sluice type of tide gates can be derived by the use of aubmergence ratio as a parameter. The results obtained are summarized as follows; 1. Discharge coefficients under submerged flow conditions can be obtained by the application of sutmergerice ratio (S) to the free flow equation of the broad-erested we r. 2. The critical submergence ratios (Scr) for the flat basin and the broad-crested types of sill have the same value of 0.8. 3. Under free flow conditions, the discharge coefficient (m) are 0.37 and 0. 35 for the flat basin and the broad-crested types of sill respectively. However, when submerged flow condition exists, the discharge coefficients for both types of sill is given by a regression equation of discharge coefficients (IL) on submergence ratios (8) expressed as; m 1.3- 1. 17S. 4. The relationships between S and Froude number (Fr), for the flat basin and the broad-crested types of sill are Fr=2. 79-2.495 and Fr2.5=5. 7-6.16S respectively. From the above relationships, it can be concluded that m can also be expressed in terms of the Froude number which is a very relevant hydraulic parameter of the open channel hydraulics.

  • PDF

The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient (송출공의 회전이 송출계수와 압력계수에 미치는 영향)

  • Ha, Kyoung-Pyo;Ku, Nam-Hee;Kauh, S.Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.

Dam Effects on Spatial Extension of Flood Discharge Data and Flood Reduction Scale I (홍수 유출자료의 공간확장과 홍수저감효과에 대한 댐 영향 분석 I)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.209-220
    • /
    • 2015
  • In this study, the effects of changed environment on spatial extension of flood discharge data which is generating discharge data at ungauged watersheds. Especially, effects of dams on spatial extensions of flood discharge data and on natural flow generation were studied. This is somehow an intial trial of flood discharge data generation for heterogeneous watersheds because of dam installation. Data extensions have been performed based on the flood discharge data from YeoJoo water gauge station located on the Nam-Han River. For the evaluation of flood discharge data spatial extension under dam effects and producing natural flow, 41 flood events associated with YeoJoo water gauge station were selected from 1986 to 2010. When flood discharge data were extended based on YeoJoo water gauge station, 77% of selected flood events were over the satisfaction ranges (NSE>0.5) of Nash-Sutcliffe Efficiency for model validation. Extended flood discharge data at Yangpyung has 0.84 NSE obtained from spatial data extension based on YeoJoo water gauge station. Generated natural flow at YeoJoo was influenced strongly by Chungju Dam which has larger effects on streamflow at YeoJoo than Hoangsung Dam. Observed peak discharges after the 1986 of Chungju Dam installation were smaller than those of the obtained natural flow. Through these results, spatial extension of flood discharge data with installed dams works efficiently for ungauged watersheds and natural flow can be generated using extended flood discharge data.

A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment (수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

A Gas Chromatographic Detector using Glow Discharge (글로우 방전을 이용한 기체크로마토그라피 검출기)

  • Han Chong Soo;Song, Seung Ho
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.350-354
    • /
    • 1991
  • Characteristics of a gas chromatographic detector using glow discharge as the ionization source was studied in helium flow. Discharge current greater than 10$_6$ A was observed from the electric field 400 V/mm for the electrode distance 1 mm. The discharge current of 0.1~0.3 mA could be used for the detection of organic compounds. Discharge current was almost constant for the helium flow rate greater than 10 ml/min, but the discharge was easily disappeared by an injection of a small amount of organic compound in the flow rate of 0~30 ml/min. From the decrement of the discharge current depend on several compounds, it was suggested that the sensitivity of the glow discharge ionization chromatographic detector is strongly influenced by the molecular weight of the compounds.

  • PDF

Study on Flow Analysis of Three-Dimensional Screw Propeller With Respect to Rotational Speed Variable

  • Moon, Byung-Young;Sun, Min-Young;Lee, Ki-Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.500-507
    • /
    • 2014
  • This study aimed at conducting a flow analysis of the pressure distribution, discharge flow rate, and consequent thrust force according to the rotational speed of a three-dimensional screw propeller, and then investigating the effect of the rotational speed on the characteristics of the screw propeller by varying the relevant speed (3200, 2400, 1600, 800 rpm). In particular, the computational domain was considered by the analysis in the blades and outlet chamber, using boundary conditions. The difference between the minimum and maximum pressures was 5.5 MPa under the given conditions. The discharge flow rate at this pressure difference was on the level of 1956.67 kg/s, as a thrust force of 47083.7 T(N) was obtained. This study showed that the discharge flow rate linearly increased with the rotational speed, proportional to the RPM, while the thrust force was gradually and steadily increased with the relevant speed. In addition, it was proved that the occurrence of cavitation under the given conditions was closely related to the decrease in the durability of the screw propeller because the thrust force depends on the speed.

Design and Implementation of Fluid Flow Generation System by using Water Captures (물받이를 이용한 유수발전장치의 설계 및 구현)

  • Son, Young-Dae;Jung, Hyun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.413-421
    • /
    • 2012
  • This paper proposes the design and implementation of fluid flow generation system by using polypropylene(PP) water capture, which harvests electric energy from the kinetic energy of tidal current or water flow and drives the desired load, and applies it to the discharge drain of Hadong thermal power plant. This experimental system is composed of water captures, driving wheel, gear trains, 10[kW] synchronous generator, and three phase rectifying circuit which drives lamp load for test. The proposed water capturing system which is composed of water captures, rope and driving wheel, rotates as caterpillar according to water flow. This system is very easy to manufacture and more economical than another type of tidal current turbines such as conventional propeller and helical type. Also, we estimated the available fluid flow energy that can be extracted from the cooling water in discharge drain based on drain's cross-sectional area. Therefore, this paper confirms the validity of proposed fluid flow generation system with water captures and the possibility of its application for renewable energy generation in discharge drain of thermal power plant, from the obtained performance characteristic of this energy conversion system.

Flow Characteristics of a Side-Weir in Rectangular Channel (구형 수로내 횡월류 흐름의 특성)

  • Park, Tae-Seon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.251-259
    • /
    • 2002
  • Flow characteristics occurring a side-weir overflow in rectangular channel is investigated in this study. A numerical model based on the two -dimensional shallow-water equations is employed to review the factors influencing on the side- weir overflow discharge and the change of flow depths and velocities. It is found that the discharge coefficient which has the most significant influence on the overflow is affected by geometric characteristics of a side-weir, Froude number of the main channel flow and the flow depth of the main channel at the starting point of a side-weir. And the discharge coefficient applicable to a practical design of a side-weir is proposed by deriving a relationship between Froude number of the main channel flow at the starting point of a side-weir and Froude number of the main channel flow.

A Study on the Performance Prediction of Automotive Water Pump with Double Discharge Single Suction (자동차용 양토출 단흡입 워터펌프의 성능 예측에 관한 연구)

  • 허형석;박경석;이기수;원종필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.27-36
    • /
    • 2004
  • A Numerical analysis has been used to predict the performance in the automotive water pump with double discharge single suction. The influence of parameters such as coolant flow rate, rotational speed, ratio of blade height and clearance has been investigated. Also, the prediction of hydraulic performances such as static pressure rise, shaft power, hydraulic power and pump efficiency is carried out on the water pump including an impeller and a volute casing. A full size water pump test bench has been developed to validate the CFD flow model. Discharge flow rate, suction pressure, discharge pressure, rotational speed and torque measurements are provided. Coolant temperature is 8$0^{\circ}C$, water tank pressure is 1 kgf/$\textrm{cm}^2$ and flow rates vary.