• Title/Summary/Keyword: disc

Search Result 3,920, Processing Time 0.034 seconds

Development of Threshing Cylinder for Reduction of Soybean Seed Damage (콩 탈곡손상 절감을 위한 콩 탈곡통 개발)

  • Cho, Yong-Jin;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.380-386
    • /
    • 2010
  • This study was carried out to develop soybean thresher which is able to reduce the soybean threshing damage in comparison to the conventional thresher. A threshing cylinder with different diameter of 480 and 384 mm at each end and with one quarter disc pegs of 60 mm radius was developed and attached to the prototype thresher. A conventional thresher which has a threshing cylinder with $\wedge$ type threshing pegs and same diameter of 480 mm at each end was used for comparative test. A series of comparative performance test was conducted using sun-yu and chung-ja soybean. For sun-yu bean, which is white and usually used for soybean paste and soy sauce, the ratio of damaged beans of prototype ranged 2-3% for 330-360 rpm which is recommended cylinder speed by manufacturer. The ratio of damaged beans of conventional thresher was 3-4% for the same range of cylinder speed. chung-ja beans with black color usually shows high damaged ratio compared with white beans, thus cylinder speed of 250-300 rpm is recommended by manufacturer to reduce the damaged ratio. For this range of cylinder speed, the damaged ratio of prototype was 1.3-1.4% and it was 2.7-6.1% for the conventional thresher. Thus prototype is able to reduce the damaged ratio 1.5-5.0% compared with conventional thresher. Prototype shows 0.4% of unthreshed soybean ratio for sun-yu bean in the optimum range of cylinder speed and it was 0.87% for the conventional thresher. For chung-ja bean, the ratio of unthreshed soybean was almost same for both prototype and conventional thresher with the value of 4.0%. The reason of high unthreshed soybean ratio for chung-ja bean compared sun-yu bean is due to the high seed moisture content of 29.11% which is much higher than that of the recommended.

3-D Inverse Dynamics Analysis of the Effect of Maximum Muscle Force Capacities on a Musculoskeletal System

  • Han, Kap-Soo;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1774-1779
    • /
    • 2014
  • It is known that muscle strength of human body can alter or deteriorate as aging. In this study, we present an inverse dynamics simulation to investigate the effect of muscle strength on performing the daily activities. A 3D musculoskeletal model developed in this study includes several segments of whole body, long and short muscles, ligaments and disc stiffness. Five daily activities such as standing, flexion, finger tip to floor, standing lift close and lifting flexed were simulated with varying the maximum muscle force capacities (MFC) of each muscle fascicles from 30 to $90N/cm^2$ with an increment of $30N/cm^2$. In the result, no solution can be obtained for finger tip to floor and lifting flexed with $30N/cm^2$. Even though the solution was available for standing lift close activity in case of $30N/cm^2$ capacity, many of muscle fascicles hit the upper bound of muscle strength which means that it is not physiologically possible to perform the acvities in reality. For lifing flexed, even the case of $60N/cm^2$ capaciy, represents the moderate healthy people, was not able to find the solutions, showing that 18 muscles among 258 muscle fascicles reached 100% of muscle capacity. The estimated results imply that people who have low muscle strength such as elders or rehabilitation patients were required higher muscle work to perform and maintain the same daily activities than healthy one.

A STUDY ON THE SHEAR BOND STRENGTH OF THE PORCELAIN LAMINATE ACCORDING TO SURFACE ROUGHNESS OF THE CUT ENAMEL (삭제된 법랑질의 표면거칠기에 따른 도재 라미네이트의 전단결합강도에 관한 연구)

  • Park, Bong-Seok;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.159-168
    • /
    • 1994
  • The purpose of this study was to evaluate the shear bond strength of the porcelain laminate specimens according to the surface roughness of the cut enamel of human anterior teeth. Flat enamel surfaces were prepared in 30 extracted human anterior teeth with diamond disc which were divided into two groups. Group 1 Coarse enamel surface group prepared with LVS-3 bur. Group 2 Fine enamel surface group prepared with superfine diamond bur. 30 teeth specimens of two group were stored in normal saline during 24 hours. 30 disk - type porcelain laminate specimens with diameter 4mm and thickness 1mm were made and sand - blasted on internal surface which were to cemented on enamel surface. Porcelain laminate specimens were cemented on enamel surface with Choice Veneer System (Bisco Dental, U.S.A) according to manufacture's instructions. All teeth specimens of two groups were manipulated with same method and stored In normal saline before testing. An Universal Testing machine (Model No.UTM-4206,Instron, U.S.A) was used to apply shear loads in the vertical directed, and the force required for separation was recorded with a cross head speed of 3mm/min and 500kg in full scale. The results were as follow ; 1. The mean shear bond strength of coarse surface group was 36.30kg and that of fine surface group was 44.39 kg, but there was no significant difference in breaking strength of two groups(p>0.05).

  • PDF

THE IN VITRO STUDY ON FLUORIDE RELEASE AND FLUORIDE UPTAKE TO DENTIN FROM FLUORIDE CONTAINING LINER / BASE CEMENTS (수종 불소함유 이장용 시멘트의 불소 유리량과 상아질로의 불소흡착정도)

  • Ko, Hyo-Jee;Chung, Hyun-Ju;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.27-37
    • /
    • 1993
  • The purpose of this study was to determine the fluroide release levels of new fluoride-containing liner/base cements and the fluoride uptake by dentin surfaces. Ten specimens of each brand (Fuji ionomer Type III, Fuji Lining LC, Timeline, Vitrebond and XR ionomer) were made, polymerized and placed in fluoride-free distilled water at $37^{\circ}C$, 100% relative humidity for 24 hours. The extracting solution of specimen was exchanged and fluoride release was measured daily for the 30 days. For fluoride uptake study, twenty-five extracted human lower molars were sectioned longitudinally in the mesiodistal direction with a diamond disc. Five teeth were filled with each material and then stored at $37^{\circ}C$, 100% humidity for 4 weeks. Fluoride uptake by dentin from the test materials was evaluated using electron probe micro X-ray analyzer. The following results were obtained : 1. The amounts of fluoride release showed no significant difference between Fuji ionomer Type III and Fuji Lining LC, but showed significant difference between other groups. XR ionomer released significantly greater fluoride than any other group(P<.001). 2. All the materials have a burst effect which more fluoride released in then first 3 day and showed significant decrease over the test period (P<0.001). 3. XR ionomer group showed fluoride penetration to approximately $50{\mu}m$ deep in dentin. But other material groups showed very little fluoride uptake by dentin.

  • PDF

Effect of intracanal medicaments used in endodontic regeneration procedures on microhardness and chemical structure of dentin

  • Yassen, Ghaeth Hamdon;Eckert, George Joseph;Platt, Jeffrey Allen
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.104-112
    • /
    • 2015
  • Objectives: This study was performed to investigate the effects of different intracanal medicaments on chemical structure and microhardness of dentin. Materials and Methods: Fifty human dentin discs were obtained from intact third molars and randomly assigned into two control groups and three treatment groups. The first control group received no treatment. The second control group (no medicament group) was irrigated with sodium hypochlorite (NaOCl), stored in humid environment for four weeks and then irrigated with ethylenediaminetetraacetic acid (EDTA). The three treatment groups were irrigated with NaOCl, treated for four weeks with either 1 g/mL triple antibiotic paste (TAP), 1 mg/mL methylcellulose-based triple antibiotic paste (DTAP), or calcium hydroxide [$Ca(OH)_2$] and finally irrigated with EDTA. After treatment, one half of each dentin disc was subjected to Vickers microhardness (n = 10 per group) and the other half was used to evaluate the chemical structure (phosphate/amide I ratio) of treated dentin utilizing attenuated total reflection Fourier transform infrared spectroscopy (n = 5 per group). One-way ANOVA followed by Fisher's least significant difference were used for statistical analyses. Results: Dentin discs treated with different intracanal medicaments and those treated with NaOCl + EDTA showed significant reduction in microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.05) compared to no treatment control dentin. Furthermore, dentin discs treated with TAP had significantly lower microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.0001) compared to all other groups. Conclusions: The use of DTAP or $Ca(OH)_2$ medicaments during endodontic regeneration may cause significantly less microhardness reduction and superficial demineralization of dentin compared to the use of TAP.

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

CHARACTERISTICS OF DIAMONDLIKE CARBON COATED ALUMINA SEALS AT TEMPERATURES UP TO $400^{\circ}C$ (플라즈마 증착방식에 의해 DLC코팅된 알루미나 세라믹의 코팅박막 특성에 관한 연구)

  • Ok, Chul-Ho;Kim, Byoung-Yong;Kang, Dong-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.397-397
    • /
    • 2007
  • Diamondlike carbon (DLC) coatings were deposited on alumina ceramic seals using a plasma immersion ion deposition technique (PIID). Then they were subjected to tribological tests using a pin-on-disc tribometer under a high load (1.3 GPa) and under elevated temperatures up to 400C. Coefficients of friction (COFs) were recorded and compared with that of the untreated alumina while the wear tracks were analyzed using SEM with EDS to characterize the DLC films. To enhance the DLC adhesion to the substrate, various interlayers including Si and Cr were deposited using the PIID process or an ion beam assisted deposition (IBAD) method. It was observed that the DLC coating, if adhering well to the substrate, reduced the COFs significantly, from 0.4-0.8 for the uncoated alumina to about 0.05-0.1, within the tested temperature range. The adhesion was determined by the interlayer type and possibly by the application method. Cr interlayer did not perform as well as the Si interlayer. This could also be due to the fact that the Cr interlayer and the subsequent DLC coating had to be done in two different processing systems, while both the Si interlayer and the subsequent DLC film were deposited in one system without breaking the chamber. The coating failure mode was found to be delamination between the Cr and the alumina substrate. In contrast, the Si interlayer with proper DLC deposition procedures resulted in very good adhesion and hence excellent tribological performance. Further study may lead to future DLC applications of ceramic seals.

  • PDF

Isolation of the Pathogenic Bacteria from Chicken and Antimicrobial Drug Sensitivity of the Strain Isolated (가금유래 주요병원성세균의 분리와 분리균주에 대한 약제감수성조사)

  • 박근식;김기석;남궁선
    • Korean Journal of Poultry Science
    • /
    • v.7 no.1
    • /
    • pp.53-64
    • /
    • 1980
  • A total of 1503 specimens were submitted to the Poultry Disease Diagnostic Service Laboratory during the year 1966 and 1978. The most frequently diagnosed diseases in order of prevalence were avian mycoplasmosis, staphylococcosis, colibacillosis, salmonellosis and pullorum disease, the percentages of the conditions being 24.6%, 20.0%, 18.0%, 12.6% and 6.4%, respectively, The drug resistance of pathogenic mirnoorganisms isolated during the year 1978 from chicken with colicabacillosis, staphylococcosis or salmonellosis were investigated by the use of disc diffusion technique, the results being as follow. 1) Drug resistance of 63 strains of Escherichia coli More than 95% of the strains tested were sensitive to colistin and gentamicin. The percentages of strains sensitive to kanamycin, chloramphenicol, ampicillin and nitrofurantoin were 66.7%, 60.3%, 60.3% and 47.6%, respectively. Majority of the strains were highly resistant to streptomycin and tetracyline. All the strains were resisistant to bacitracin lincomycin, oleandomycin, penicillin and erythromycin. All the strains tested were resistant to more than two among 10 drugs in common use such as penicillin, erythromycin, streptomycin, tetracycline, neomycin, chloramphenicol, kanamycin, ampicillin and gentamicin, and 27 different resistance patterns were noted. The most frequent multiple resistance pattern was PC, EM, SM and TC (11.1%). 2) Drug resistance of 48 strains of Salmonella More than 95% of the strains tested were sensitive to colistin, gentamicin ana ampicillin. The percentages of st rains sensitive to kanamycin, tetracycline, neomycin and nitrofurantoin were 81,3%, 79%, 72.9%, and 68.0% respectively. None of them was sensitive to streptomycin, oleandomycin, erythromycin, lincomycin and bacitracin. All the strains were resistant to more than one among 7 drugs in common use such as streptomycin, erythromycin, neomycin, tetracycline, kanamycin, ampicillin and gentamicin. The most frequent resistance pattern was SM and EM(66.7%). 3) Drug resistance of 54 strains of Staphylococci All the strains tested were sensitive to gentmaicin, kanamycin and cephalothin. Majority of them were highly sensitive to bacitracin, methicillin, nitrofurantoin and chloramphenicol. The Percentages of strains sensitive to streptomycin, ampicillin, lincomycin and tetracycline were 66.7%, 55.6%, 44.4% and 27.8%, respectively. Among them, 51 strains were resistant to more than one among 11 drugs in common use such as tetracycline, lincomycin, ampicillin, penicillin, streptomycin, erythromycin, neomycin, oleandomycin, chloramphenicol, methicillin and bacitracin, and thirty one different resistance patterns were noted.

  • PDF

Effect of Combined Refining Plates with Different Bar Angles on Paper Properties during Mixed Pulp Refining

  • GUO, Xiya;DONG, Jixian;LIU, Huan;DUAN, Chuanwu;YANG, Ruifan;QI, Kai
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.581-590
    • /
    • 2020
  • Pulp refining is the major way to alter the properties of fibers and formed paper. Different combinations of the bar profile of the rotor and stator during low consistency refining processes directly affect the properties of the paper. In this study, a mixture of softwood and hardwood pulp was refined by varying the bar angle of the stator while that of the rotor is fixed at 0º. The pulp samples were collected at different refining times. Then, the pulp and paper properties, such as beating degree, fiber external fibrillation, and tensile and tear indexes were measured to explore the effects of the combined refining plates at different bar angles on paper properties. The results of the experiment show that the combined refining plate of 0º and 5º recorded the most significant improvement in the pulp beating degree and fiber external fibrillation. This consequently increased the fiber bonding area, which in turn, improved both the tensile and the tear indexes of the paper. Also, the influence of the combined refining plates with a larger bar angle on the paper properties was weaker compared to that of smaller angles. This study not only provides ideas for the bar profile design but also improves the optimal selection of refining plates.

Clinical Study of Augmentin (Augmentin 의 임상효과)

  • Kim, Hyeong-Muk;Im, Chang-Yeong
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.174-179
    • /
    • 1986
  • Augmentin is a formulation of amoxycillin trihydrate and potassium clavulanate, a fused beta-lactam molecule produced by the fermentation of Streptomyces clavuligerus. Most clinically important resistance is due to the production by bacteria of antibiotic destroying enzymes. In the case of penicillins and cephalosporins these enzymes are termed beta-lactamase as they destroy the beta-lectern ring of these antibiotics, completely inactivating them. The presence of clavulanic acid extends the spectrum of amoxycillin to include bet On clinical study of the intravenous Augmentin in the field of thoracic and cardiovascular surgical cases, we selected randomly 30 patients, 21 male and 9 female, age from 13 to 72, in the period from April to December 1985. Among the total 30 patients, 22 were preoperatively infected [11 thoracic empyema, 5 lobar pneumonia, 2 lung abscess, 2 bronchiectasis, one acute pyelonephritis with ureter stone and one rheumatic carditis], and 8 were not infected preoperatively [Table 1, 2]. Of the preoperatively infected group, 11 cases [50%] were culture positive [4 staphylococcus, 3 pseudomonas, 2 Serratia group, and one E. coli], and preoperatively non-infected group [8 cases] revealed expectedly negative findings on bacterial culture. All of the culture positive bacteria were sensitive to Augmentin on disc culture sensitivity test except one case of E. coli. Daily doses of intravenous Augmentin were 2.-1-6.0gm divided in 2-5 injections. Every injection administered [1.2gm at Augmentin dissolved in 20ml distilled water] slowly for more than 20 minutes. Duration of injection was variable according to the clinical conditions from minimum 5 to maximum 31 days. The results of antibiotic treatment with Augmentin and some other antibiotic combinations pre- and postoperatively were subgrouped as EXCELLENT, EFFECTIVE, and FAILURE. Clinical criteria of the therapeutic result were symptomatic, objective and laboratory improvement. 8 cases were excellent, 13 effective, and one failure among the preoperatively infected group, and all 8 cases of the preoperatively non-infected group were effective as pro;hylactive antibiotic therapy. Overall effective ratio was 97% in both subgroup. There was no side effect clinically and laboratory study including liver and kidney function test during and after the I.V. administration of Augmentin. Oral swallow tablets which were administered after discharge from hospital also revealed good effects with some degree of gastrointestinal trouble.

  • PDF