• Title/Summary/Keyword: disaster safety information

Search Result 993, Processing Time 0.03 seconds

Probabilistic Prediction of the Risk of Sexual Crimes Using Weight of Evidence (Weight of Evidence를 활용한 성폭력 범죄 위험의 확률적 예측)

  • KIM, Bo-Eun;KIM, Young-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.72-85
    • /
    • 2019
  • The goal of this study is to predict sexual violence crimes, which is an routine risk. The study used to the Weight of Evidence on sexual violence crimes that occurred in partly Cheongju-si for five years from 2011 to 2015. The results are as follows. First, application and analysis of the Weight of Evidence that considers the weight of evidence characteristics showed 8 out of total 26 evidences that are used for a sexual violence crimes risk prediction. The evidences were residential area, date of use permission for building, individual housing price, floor area ratio, number of basement floor, lot area, security light and recreational facility; which satisfied credibility in the process of calculating weight. Second, The weight calculated 8 evidences were combined to create the prediction map in the end. The map showed that 16.5% of sexual violence crimes probability occurs in 0.3㎢, which is 3.3% of the map. The area of probability of 34.5% is 1.8㎢, which is 19.0% of the map and the area of probability of 75.5% is 2.0㎢, which is 20.7% of the map. This study derived the probability of occurrence of sexual violence crime risk and environmental factors or conditions that could reduce it. Such results could be used as basic data for devising preemptive measures to minimize sexual violence, such as police activities to prevent crimes.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Identifying Specifications of Flat Type Signboards Using a Stereo Camera (스테레오 카메라를 이용한 판류형 간판의 규격 판별)

  • Kwon, Sang Il;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.1
    • /
    • pp.69-83
    • /
    • 2020
  • Signboards are standardized according to national legislation for the safety of pedestrians and disaster prevention in urban areas. Signboards should be installed according to the standard. However, it is not easy to manage the signboards systematically due to the number of signboards that have been installed for a long time and frequently changing stores. In this study, we proposed a methodology for distinguishing signboards that deviated from the standard. To this end, the signboard was photographed using a stereo camera, and then the three-dimensional coordinates of the signboard were determined from the signboard image to calculate the signboard's horizontal and vertical dimensions to determine the signboard's specifications. In order to determine the interior and relative orientation parameters of the stereo camera, an outdoor three-dimensional building was used as the test field. Then, the image coordinates of four vertices of the signboard were extracted from the signboard image taken from about 15m ~ 22m distance using deep learning. After determining the signboard's three-dimensional coordinates by using the interior and relative orientation parameters of the stereo camera and the image coordinates of the four vertices of the signboard, the horizontal and vertical sizes of the signboard were calculated, resulting in an error of about 2.7cm on average. The specifications for the ten flat-type signboards showed that all of the horizontal sizes were compliant with the specifications, but the vertical sizes exceeded about 36.5cm on average. Through this, it was found that maintenance of flat-type signboards is needed overall.

A Study on Risk Factor Identification by Specialty Construction Industry Sector through Construction Accident Cases : Focused on the Insurance Data of Specialty Construction Worker (건설재해사례 분석에 의한 전문건설업종별 위험요인 탐색 : 전문건설업 근로자 공제자료를 중심으로)

  • Lee, Young Jai;Kang, Seong Kyung;Yu, Hwan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.45-63
    • /
    • 2019
  • The number of domestic construction company is expanding every year while the construction workers' exposure to disaster risk is increasing due to technological advancements and popularity of high-rise buildings. In particular, the industry faces greater fatalities and severe large scale accidents because of construction industry characteristics including influx of foreign workers with different language and culture, large number of aged workers, outsourcing, high place work, heavy machine construction. The construction industry is labor-intensive, which is to be completed under given timeline and consists of unique working environment with a lot of night shifts. In addition, when a fixed construction budget is not secured, there is less investment in safety management resulting in poor risk management at the construction site. Taking account that the construction industry has higher accident risk rate and fatality rate, risky and unique working environment, and various labor pool from foreign to aged workers, preemptive safety management through risk factor identification is a mandatory requirement for the construction industry and site. The study analyzes about 8,500 cases of construction accidents that occurred over the past 10 years and identified risk factor by construction industry sector to secure a systematic insight for risk management. Based on interrelation analysis between accident types, work types, original cause materials and assailing materials, there is correlation between each analysis factor and work industry. Especially for work types, there is great correlation between work tasks and industry type. For reinforced concrete and earthwork are among the most frequent types of accidents, and they are not only high in frequency of accidents, but also have a high risk in categories of occurrence.

A Study on the Appropriate Management of Maritime Police Authority in Korea Coast Guard: Focusing on the Japan Coast Guard (해양경비안전본부의 해양경찰권 적정 운영방안에 관한 연구: -일본 해상보안청과의 비교를 중심으로-)

  • Son, Yeong-Tae
    • Korean Security Journal
    • /
    • no.42
    • /
    • pp.361-391
    • /
    • 2015
  • Regarding the [Government Organization Act; which is legislated on 19th November, 2014] Korea Coast Guard(KCG) has been re-organized and belong from Korea Coast Guard shall be established under the Minister of Oceans and Fisheries to Ministry of Public Safety and Security. Furthermore, National Police Agency(NPA) Commissioner has the right for administer duties concerning investigation and information by succession from Korea Coast Guard Commissioner. That means that main rule has been moved from prior KCG to Ministry of Public Safety and Security(MPSS) and NPA currently which is dual structure. Meanwhile, This kind of organization change has been effective to investigative agency which exert KCG's call of duty and causes needs of variety problems. In other words, There are quite huge changes such as KCG's reduction of their work, call of duty and re-organization regarding revised government organization act. However this change - including re-organization by government, was not able to take current MPSS's special features such as organization specialty and legal rights. It means, the current change has not been taken present law system CRIMINAL PROCEDURE LAW and there was no preparation to stable maritime police authority action as well. To sum up, this revised GOVERNMENT ORGANIZATION ACT is supposed to provide total, quick security service by establishing strong disasters and safety control tower. However they only contains few area such as organization revision regarding 'Sewol Ferry Disaster', they was not able to contain the other parts of Society. Therefore, in this article I would like to check the part of re-evaluation of current change made by KCC's organization revision. It is supposed to provide better legal stability by making clear of work area by government agencies who acts maritime police authority.

  • PDF

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

A Case Study on the Implementation of Integrated Operation System of the Nakdong River Estuary Barrage Due to the Drainage Gate Extension (낙동강 하굿둑의 배수문 증설에 따른 통합운영시스템의 구축 사례에 대한 연구)

  • Kim, Seokju;Lim, Taesoo;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.1
    • /
    • pp.183-199
    • /
    • 2015
  • Due to the Four Major Rivers Restoration Project, Nakdong River Estuary Barrage's designed flood quantity has been largely increased, and this has caused to construct several drainage gates at the right side of Eulsukdo island to secure the safety of downstream river area. For successful functioning of Nakdong River Estuary Barrage, such as flood control, disaster prevention, and the securing of sufficient water capacity, drainage gates at the both sides of island have to operate systematically and reliably. To manage this under restricted personnel and resources, we have implemented the IOS (Integrated Operation System) by integrating previous facilities and resources via information and communication technologies. The IOS has been designed to have higher availability and fault tolerance to function continuously even with the partial system's failure under the emergency situation like flood. Operators can use the system easily and acknowledge alarms of facilities through its IWS (Integrated Warning System) earlier. Preparing for Integrated Water Resources Management and Smart Water Grid, the architecture of IOS conformed to open system standards which will be helpful to link with the other systems easily.

An Experimental Study on Bearing Capacity of Drilled Shaft with Mid-size (중구경 현장타설말뚝의 지지력 특성에 관한 실험적 연구)

  • Lee, Kwang-Wu;You, Seung-Kyong;Park, Jeong-Jun;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.263-272
    • /
    • 2019
  • This paper describes the results of bearing capacity using field loading test of pile, in order to extend the applicability of drilled shaft with mid-size, and the results were compared with the prediction results of design bearing capacity by empirical formular. The static load test result showed that the allowable bearing capacity of high pile strength was about 2.4 times higher than that of low pile strength. The dynamic load test result showed that the allowable bearing capacity of high pile strength was about 1.4 times~1.5 times higher than that of low pile strength. The comparison result of allowable bearing capacity between static and dynamic load test showed that the difference of allowable load ranged from 3% to 6% under the same settlement conditions. As a result of comparing the ultimate bearing capacity by load test and design bearing capacity, it was found that the FHWA proposed equation could be more reasonable than the other proposed equation in load sharing ratios of end bearing and skin friction.

A 2-D Location Determination Model of Buried Persons in Collapsed Shape using Optimal Wireless Communication Technology (최적 무선통신 기술을 활용한 붕괴지형 매몰자의 2차원 매몰위치 결정 모델)

  • Moon, Hyoun-Seok;Lee, Woo-Sik;Lee, Gun-Woo;Han, Dong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8879-8888
    • /
    • 2015
  • When the disaster like earthquake in urban area occur, due to the collapse accidents for subway, tunnel space with buildings or underground area, enormous property and human damage are happened. Specially, since it is difficult to identify survived status of humans within collapsed debris and accurately buried locations of the humans, inputs of considerable time and manpower for rescuing them are required. Besides, secondary damage can be occurred by additional collapses. The aim of this study is to propose a stochastic location positioning method that enables to provide aid information by determining locations of mobile devices for buried persons in 2-D plane using wireless communication technologies. This study selected a detection method for buried persons based on Wi-Fi signal, and identified characteristics of signal strengths by distance unit. Using these methods, a stochastic location detection model in 2-D plane was built. It is expected that this technology will be utilized as a core technology that can protects safety and human life of the public by providing data for rescuing quickly buried persons in cases of national disasters for future.