• Title/Summary/Keyword: disaster case

Search Result 1,278, Processing Time 0.032 seconds

Clinical Evaluation of Microreplantation in the Digital Amputation (수지절단손상에 대한 재접합술의 평가와 분석)

  • Lee, Tae-Hoon;Woo, Sang-Hyeon;Choi, See-Ho;Seul, Jung-Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.23-32
    • /
    • 1988
  • Finger injuries are becoming more common with the increasing use of mechanical industrial and household appliances. Among the hand injuries, amputation is the serious disaster to the patient. Recently, application of microsurgical technique to the reattachment of ampuatated digits has been common clinical procedures. We performed microsurgical replantation to the 75 patients with 102 digits from march in 1986 to february in 1988. The following results were obtained. 1. The most common age distribution was third decade and male to female ratio was about 5:1. 2. The ratio of right to left hand was about 1:1 but the dominant to non-dominant hand was about 2:1. 3. The index finger was most commonly injured and the next was middle finger. 4. The most common type of the injuries was the crushing injury and the most common vector was a kind of pressor. 5. The anesthesia was performed in equal ratio between the general and regional anesthesia. 6. The survival rate of microreplantation to the injuries of the zone II was 77.8% and zone III was 80%. 7. The functional result after replantation at zone II was better than zone III. 8. Microreplantation was performed in any case of the type of the injury, the severity of crushing and the ischemic time, and the patients requirement was an important factor.

  • PDF

Verification of Applicability of Emergency Recovery Scenario Applying Field Recovery Case (현장복구사례를 이용한 긴급복구 시나리오의 적용성 검증)

  • Yoon, Hyuk-Jin;Jung, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.632-638
    • /
    • 2018
  • Recently, damage to waterside structures, such as bridges or retaining walls, is increasing due to typhoons, flooding, aging, etc. In such cases, the damage is not limited to the structures themselves, but can include effects on a wider scale, such as the suspension of and restriction of access to the facilities, human injury, economic loss, etc. To preclude such damage, recovery methods suitable for the particular field circumstances should be applied when damage occurs. By enforcing prompt repairs, the material and human damage and losses that can occur can be minimized. Since the impact of losses caused by damage and disaster increases with the elapse of time, emergency recovery is even more important. In the emergency recovery process, appropriate repair and reinforcement is crucial. In the present study, the derivation scenarios of the emergency recovery method were applied to some field recovery cases, and their applicability was verified by comparison with the recovery methods actually used. It is expected that the results of this study will be useful for practical application, by suggesting more appropriate recovery methods.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

Inundation Analysis of Suyoung.Mangmi Lowland Area Using SWMM and FLUMEN (SWMM과 FLUMEN을 이용한 수영.망미 저지대의 침수 분석)

  • Kang, Tae-Uk;Lee, Sang-Ho;Jung, Tae-Hun;Oh, Jai-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.149-158
    • /
    • 2010
  • Recent rainfall patterns in Korea show that both of the total amount of rainfall and the total number of heavy rain days have been increased. Therefore, the damage resulted from flood disaster has been dramatically increased in Korea. The purpose of the present study is to analyze flooding in an urban area using SWMM linked with FLUMEN. The study area is Suyeong-Mangmi lowland area, Busan, Korea. Suyeong-Mangmi lowland area have been a flooding hazard zone since 1995. The last flooding cases of this area occurred on July 7th and 16th, 2009, and the later flooding case was analyzed in this study. The first step of computation is calculating flow through storm sewers using the urban runoff simulation model of SWMM. The flooding hydrographs are used in the inundation analysis model of FLUMEN. The results of inundation analysis were compared with the real flooding situation of the study area. The real maximum inundation depth was guessed by 1.0 m or more on July 16th. The computation yields the maximum inundation depth of 1.2 m and the result was somewhat overestimated. The errors may be resulted from the runoff simulation and incapability of simulation using FLUMEN for flow into buildings. The models and procedures used in this study can be applied to analysis of flooding resulted from severe rainfall and insufficiency of drainage capacity.

Preliminary Estimation of Earthquake Losses Based on HAZUS in a Coastal Facility Area with Blocks Applying Site Classification (블록별 부지분류 적용 해안시설 영역에서의 HAZUS 기반 지진피해 추정)

  • Sun, Chang-Guk;Chun, Sung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.10-27
    • /
    • 2014
  • HAZUS-MH is a GIS-based computer program that estimates potential losses from multi-hazard phenomena: earthquakes, floods and hurricanes. With respect to seismic disaster, characteristics of a hypothetical or actual earthquake are entered into HAZUS. Then HAZUS estimates the intensity of ground shaking and calculates the correspondent losses. In this study, HAZUS was used as a part of the preparations of the future seismic events at a coastal plant facility area. To reliably characterize the target facility area, many geotechnical characteristics data were synthesized from the existing site investigation reports. And the buildings and facilities were sorted by analyzing their material and structural characteristics. In particular, the study area was divided into 17 blocks taking into account the situation of both land development and facility distribution. The ground conditions of blocks were categorized according to the site classification scheme for earthquake-resistant design. Moreover, seismic fragility curves of a main facilities were derived based on the numerical modeling and were incorporated into the database in HAZUS. The results estimated in the study area using HAZUS showed various seismic damage and loss potentials depending on site conditions and structural categories. This case study verified the usefulness of the HAZUS for estimating earthquake losses in coastal facility areas.

Behavior Characteristics of Micropile Following the Embedded Condition (근입조건에 따른 마이크로파일의 거동특성)

  • Bang, Seongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.6
    • /
    • pp.19-25
    • /
    • 2020
  • In the recent downtown works, there are frequent cases where the work on existing piles is impossible due to the influence from lack of space and surrounding environment. In such cases, there has been growing cases of using the micropile method that is available to work with the small equipment and asserts the bearing capacity of the existing piles. The micropile method is a type of drilled shaft with the diameter of a pile to be around 75 mm~300 mm that, even for a case where it has certain surrounding structure, foundation and spatial obstacle, there is almost no work difficulty and the work is feasible under all types of soil conditions. In addition, the work can be done in places where the ceiling of the building is low with less vibration and noise in the work process that such method is significantly used for foundation reinforcement of existing buildings. With respect to the motion characteristics that are changed depending on the foundational characteristics or when the micropile is applied with compression or tensile force, there is very few studies conducted. Therefore, under this study, through the data analysis of the field loading test regarding the micropile worked in the fields, it clarifies the settlement and characteristics of bearing capacity following the embedded condition of the ingredients and piles that consist the foundation if the compression and tensile force are applied to the micropile, and by facilitating the statistical analysis program, SAS, to carry out the analysis on the main elements influencing on settlement of the micropile and bearing capacity.

A Revisit to the Recent Human Error Events in Nuclear Power Plants Focused to the Organizational and Safety Culture

  • Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.117-124
    • /
    • 2013
  • Objective: This paper presents additional considerations related to organization and safety culture extracted from recent human error incidents in Korea, such as station blackout(i.e., SBO) in Kori#1. Background: Safety culture has been already highlighted as a major cause of human errors after 1986 Chernobyl accident. After Fukushima accident in Japan, the public acceptance for nuclear energy has taken its toll. Organizational characteristics and culture became elucidated as a major contributor again. Therefore many nuclear countries are re-evaluating their safety culture, and discussing any preparedness and its improvement. On top of that, there was an SBO in 2012 in the Kori#1. Korean public feels frustrated due to the similar human errors causing to a catastrophe like Fukushima accident. Method: This paper reassesses Japan's incidents, and revisits Korea's recent incidents. It focuses on the analysis of the hazards rather than the causes of human errors, the derivation of countermeasures, and their implementation. The preceding incidents and conclusions from Japanese experience are also re-analyzed. The Fukushima accident was an SBO due to the natural disaster such as earthquakes and a successive tsunami. Unlike the Fukushima accident, the Kori#1 incident itself was simple and restored without any loss and radioactive release. However, the fact that the incident was deliberately concealed led to massive distrust. Moreover, the continued violation of rules and organized concealment of the accident are serious signs of a new distorted type of human errors, blatantly revealing the cultural and fundamental weakness of the current organization. Result: We should learn from Japanese experiences who had taken pride in its safety technology and fairly high confidence in safety culture. Japan's first criticality accident in JCO facility splashed cold water on that confidence. It has turned out to be a typical case revealing the problems in the organization and safety culture. Since Japan has failed to gain lessons and countermeasure, the issue persists to the Fukushima incident. Conclusion: Safety culture is not a specific independent element, which makes it difficult to either evaluate it properly or establish countermeasures from the lessons. It may continue to expose similar human errors such as concealment of incident and manipulation of bad data. Application: Not only will this work establish the course of research for organization and safety culture, but this work will also contribute to the revitalization of Korea's nuclear industry from the disappointment after the export contract to UAE.

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

Case Study on the Hazard Susceptibility Prediction of Debris Flows using Surface Water Concentration Analysis and the Distinct Element Method (수계 집중도 분석 및 개별요소법을 이용한 토석류 위험도 예측 사례 연구)

  • Lee, Jong-Hyun;Kim, Seung-Hyun;Ryu, Sang-Hoon;Koo, Ho-Bon;Kim, Sung-Wook
    • The Journal of Engineering Geology
    • /
    • v.22 no.3
    • /
    • pp.283-291
    • /
    • 2012
  • Various studies regarding the prediction of landslides are underway internationally. Research into disaster prevention with regard to debris flows is a particular focus of research because this type of landslide can cause enormous damage over a short period. The objective of this study is to determine the hazard susceptibility of debris flow via predictions of surface water concentrations based on the concept that a debris flow is similar to a surface water flow, as it is influenced by mountain topography. This study considered urban areas affected by large debris flows or landslides. Digital mapping (including the slope and upslope contributing areas) and the wetness index were used to determine the relevant topographic factors and the hydrology of the area. We determined the hazard susceptibility of debris flow by predicting the surface water concentration based on the topography of the surrounding mountainous terrain. Results obtained using the distinct element method were used to derive a correlation equation between the weight and the impact force of the debris flow. We consider that in using a correlation equation, this method could assist in the effective installation of debris-flow-prevention structures.

A Study on The Possibility of Flash Fire of Combat System by Kinetic Energy Ammunitions (운동에너지탄에 의한 전투시스템의 순간화재 발생가능성에 대한 연구)

  • Park, Young Ju;Lee, Eun Min;Lee, Hae Pyeong;Hwang, Me Jung;Lee, Chang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • This study analyzed various possibilities of flash fire which could occur in a variety of combats, in order to predict that of flash fire of combat system armor using Autodyn program. The possibility was judged by the temperature distribution of fuels, which was caused by the impact of parts of fuel systems through an armor, in the event of getting shot by external ammunition. Diverse variables could affect the possibility of flash fire: external ammunition(Type A: penetration 570 mm, Type B: penetration 410 mm), fuels(Gasoline, Diesel, Kerosene), the thickness of an armor(100, 200, 300, 400, 500 mm), the gap of a fuel tank and an armor(45, 95, 145, 195, 245, 295 mm). As a result, when an armor was 20 mm think, the temperature of 3 fuels ranged like this: Gasoline 372~387 K, Diesel 442~408 K, Kerosene 384~395 K. Although they made a little difference among them, they all didn't reach their ignition points. When an armor was 200 mm think, each fuel reached the maximum temperature, not reaching its ignition points as well. The thicker an armor was, the lower the temperature got. When Type B ammunition was used, the temperature of fuels went up 19~59 K higher than Type A was used. In the case that the gap of fuel tank and an armor was 20 mm thick, the temperature distribution of Gasoline showed 389~450 K, the maximum temperature appeared in the gap of 145 mm, and the minimum temperature 295 mm. For Type B, the temperature distribution of fuels ranged 386~401 K, the maximum temperature appeared in the gap of 245 mm, and the minimum temperature 45 mm. There was no significant difference between two cases, and neither of them reached its ignition point. Accordingly, as the tested fuels of combat systems didn't reach their ignition points, it is thought that the possibility of flash point of an armor is low.