• 제목/요약/키워드: direction of needle

검색결과 79건 처리시간 0.027초

고종횡비를 갖는 용액기반 원통형 마이크로렌즈 제조 (Fabrication of Solution-Based Cylindrical Microlens with High Aspect Ratio)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.70-76
    • /
    • 2021
  • A cylindrical microlens (CML) has been widely used as an optical element for organic light-emitting diodes (OLEDs), light diffusers, image sensors, 3D imaging, etc. To fabricate high-performance optoelectronic devices, the CML with high aspect ratio is demanded. In this work, we report on facile solution-based processes (i.e., slot-die and needle coatings) to fabricate the CML using poly(methyl methacrylate) (PMMA). It is found that compared with needle coating, slot-die coating provides the CML with lower aspect ratio due to the wide spread of solution along the hydrophilic head lip. Although needle coating provides the CML with high aspect ratio, it requires a high precision needle array module. To demonstrate that the aspect ratio of CML can be enhanced using slot-die coating, we have varied the molecular weight of PMMA. We can achieve the CML with higher aspect ratio using PMMA with lower molecular weight at a fixed viscosity because of the higher concentration of PMMA solute in the solution. We have also shown that the aspect ratio of CML can be further boosted by coating it repeatedly. With this scheme, we have fabricated the CML with the width of 252 ㎛ and the thickness of 5.95 ㎛ (aspect ratio=0.024). To visualize its light diffusion property, we have irradiated a laser beam to the CML and observed that the laser beam spreads widely in the vertical direction of the CML.

토출 및 흡입 Needle을 이용한 유기 박막 패터닝 공정 (A Patterning Process for Organic Thin Films Using Discharge and Suction Needles)

  • 김대엽;신동균;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제19권1호
    • /
    • pp.79-84
    • /
    • 2020
  • Unlike a printing process, it is difficult to pattern organic thin films in the longitudinal (coating) direction using a coating process. In this paper, we have investigated the feasibility of patterning organic thin films using needles. To this end, we have slot-coated an aqueous poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) solution in the form of a fine stripe or large area and then applied the dual needle; one for discharging the main solvent of the underlying thin film and the other for sucking the dissolved thin film. We have found that the pattern width and depth increase as the moving speed of the plate decreases. However, it is observed that the sidewall slope is very gentle (the length of the slope is of the order of 200 ㎛) due to the fact that the discharged main solvent is widely spread and then isotropic etching occurs. With this scheme, we have also demonstrated that a fine stripe can be obtained by scanning the dual needle closely. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the patterned PEDOT:PSS stripe and observed the insulation property in the strong light-emitting stripe.

Microstructural improvement in polycrystalline Si films by crystallizing with vapor transport of Al/Ni chlorides

  • Eom, Ji-Hye;Lee, Kye-Ung;Jun, Young-Kwon;Ahn, Byung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.315-318
    • /
    • 2004
  • We developed a vapor induced crystallization (VIC) process for the first time to obtain high quality polycrystalline Si films by sublimating the mixture of $AlCl_3$ and $NiCl_2$. The VIC process enhanced the crystallization of amorphous silicon thin films. The LPCVD amorphous silicon thin films were completely crystallized after 5 hours at 480 $^{\circ}C$. It is known that needle-like grains with very small width grow in the Ni-metal induced lateral crystallization. In our new method, the width of grains is larger because the grain can also grow perpendicular to the needle growth direction. Also the interface between the merging grain boundaries was coherent. As the results, a polycrystalline film with superior microstructure has been obtained.

  • PDF

Fabrication of Barium Ferrite Films by Sol-Gel Dip Coating and Its Properties.

  • T. B. Byeon;W. D. Cho;Kim, T. O.
    • Journal of Magnetics
    • /
    • 제2권1호
    • /
    • pp.16-21
    • /
    • 1997
  • Those were investigated, the crystallographic, morphological, and magnetic properties of barium ferrite film (SiO2/Si substrate) prepared by sol-gel dip coating. Appropriate sol was prepared by dissolvin barium and iron nitrate in ethylene glycol at 80$^{\circ}C$. To obtain the films, thermally oxidized p-type silicon substrate with (111) of crystallographic orientation were dipped into the sol, dried at 250$^{\circ}C$ to remove organic material, and heated at 800$^{\circ}C$ for 3 hours in air for the crystallization of barium ferrite. It was found that the particles of barium ferrite formed on the substrate exhibited needle-like shape placing parallel to the substrate and its c-axis is long axis direction. There was tendency that the coercive force in horizontal direction to the substrate was higher than that in vertical direction to it. This tendency was profound in large thickness.

  • PDF

신문(神門), 태백혈(太白穴)에 시행된 직자법(直刺法), 수기사법(手技瀉法) 및 침습형 레이저 시술이 고혈압 백서에 미치는 영향 (The effects of traditional acupuncture techniques and green laser acupuncture on the blood pressure in hypertensive rat induced by two kidney one clip)

  • 나창수;윤대환;최찬헌;이석희;오광환;정성호
    • Korean Journal of Acupuncture
    • /
    • 제25권2호
    • /
    • pp.199-210
    • /
    • 2008
  • Objectives : This study was performed to investigate the effect of invasive laser acupuncture therapy with green light (LAT-G) at HT7(Sinmun), SP3(Taebaek) on the blood pressure in hypertensive rat induced by two kidney one clip. Methods : The experiments were performed on Sprague Dawley rats. 2K1C hypertension model was prepared by constricting the left renal artery with a sliver clip. Animals were divided into four groups, which were simple acupuncture treatment group with straight needle insertion on the square(AT-SS), acupuncture treatment group with reducing manipulation in the opposite channel direction(AT-RD), laser acupuncture treatment group with green light 532 nm, 10mW power in the opposite channel direction(LAT-G10) and laser acupuncture treatment group with green light 532 nm, 20mW power in the opposite channel direction(LAT-G20). The treatments were performed once per two days for 10 days. Results : Body weight was increased significantly in LAT-G20 group compared with AT-RD group. The blood pressure was significantly decreased in LAT-G20 and LAT-G10 groups compared with AT-SS group. Conclusions : These results suggest that green laser acupuncture therapy at SP3 ${\cdot}$ HT7 is more effective than straight needle insertion on the square for controlling hypertension. It is possible that invasive green laser acupuncture therapy (532 nm) can be used as a reducing method of the traditional acupuncture techniques.

  • PDF

경피적 최소침습 척추시술 중 디스크 내에서 방향제어가 가능한 Bio-SMA 캐뉼라 카테터의 개발 (Development of Controllable Cannular Catheter using Bio Shape Memory Alloy (SMA) during Percutaneous Minimally Invasive Spine Surgery)

  • 김철웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.378-383
    • /
    • 2007
  • As the Minimally Invasive Surgery (MIS) is developed, an interventional procedure becomes the major of the spine surgery in the world. Despite of the use of the expensive medical equipments, the success chance of the nucleoplasty is about 30%. The reason is that the shape of the cannular needle is similar to that of the conventional injector and looks like the straight. Because the tip of these straight needles is not able to reach in the vicinity of the disc bulging or the protrusion, which are the cause of the low back pain and because the far indirect plasma discharge results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body cannula device. If 3-D direction controllable cannular catheter (whose direction is accurately controlled after inserting into the bodies to cure the lesion) is developed, it is expected that new devised cannular catheter can cure many incurable diseases simultaneously. Therefore, the aims of this research are to develop the new devised cannular catheter of SMA direction controller for the medical situation, which has been produced through many previous trial-error procedures, and to produce the commercial medical device.

  • PDF

소나무 잎을 이용한 대기 중 다이옥신/퓨란 발생원 추정 (Source Tracking of PCDD/Fs in Ambient Air Using Pine Needles)

  • 천만영;김정수;고도현
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.49-60
    • /
    • 2015
  • Objectives: Pine needles were used as a passive air sampler (PAS) of atmospheric persistent organic pollutants (POPs). This study was performed to investigate concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) deposited on pine needles near a waste incinerator and PCDD/Fs source contributions using principal component analysis (PCA). Methods: Two-year-old pine needles were sampled at 11 points with respect to distance and wind direction from the incinerator. PCDD/Fs deposited on pine needles were analyzed with HRGC/HRMS. The source contribution of PCA was calculated with SPSS. Results: The average concentration of PCDD/Fs deposited on pine needle was 0.79 (0.27-1.76) pg TEQ/g dry, PCDDs with 0.24 (0.01-0.95) pg TEQ/g dry and PCDFs with 0.56 (0.27-0.82) pg TEQ/g dry, respectively. The average concentration fraction of PCDDs was 29.7%, that of PCDFs was 70.3%, and PCDFs were more prevalent than PCDDs. The contributions of PCDD/Fs sources were estimated as incineration at 58.3% and automobiles at 28.4%. However, a relation and regulation between PCDD/Fs concentrations deposited on pine needles and distance from incinerator or wind direction was not shown. Conclusion: It was concluded that atmospheric PCDD/Fs concentrations near an industrial complex with a waste incinerator were affected by multiple sources. However, PCDD/Fs concentrations were lower than in other inland cities with the exception of background area.

A12O3을 하지층으로 하는 Ba-ferrite 박막의 제조 및 자기적 특성에 관한 연구 (The Preparation and Magnetic Properties in Ba-ferrite Film on the A12O3 Substrate)

  • 서정철;박철진;최정완
    • 한국자기학회지
    • /
    • 제15권2호
    • /
    • pp.125-129
    • /
    • 2005
  • $A1_2O_3$ 기판을 하지층으로 하는 Ba-ferrite 박막을 pulsed laser deposition system으로 제조하여 결정학적 및 자기적 성질을 SEM, $M\ddot{o}ssbauer$ 분광법 및 VSM을 사용하여 연구하였다. Ba-ferrite박막은 $A1_2O_3$ 기판위에 PLD를 이용하여 기판온도 $400^{\circ}C$, 산소압력 0.1 Torr로 증착 하였고 증착 시간을 달리하여 두께 조절하였다. Ba-ferrite 박막은 5분 증착한 시료에서만 판상으로 결정이 형성되었음을 볼 수 있고 그보다 두꺼운 시료의 경우에는 침상모양과 판상모양이 임의의 방향으로 혼재되었음을 확인하였다. $M\ddot{o}ssbauer$ssbauer 분광법으로부터 측정된 Ba-ferrite결정 내 Fe 원자의 스핀 방향은 두께가 얇을수록 판상의 결정이 많이 존재하여 기판에 수직으로 정렬하려는 경향을 보이고 있다. VSM으로 측정한 자기이력곡선은 판상과 침상의 상이한 2가지 형태가 공존하는 것으로 나타났다.

Effects of Manufacturing Technology on the Mechanical Properties of Alfa Fiber Non-woven Reinforced PMMA Composites

  • Wanassi, Bechir;Jaouadi, Mounir;Hassan, Mohamed Ben;Msahli, Slah
    • Composites Research
    • /
    • 제28권3호
    • /
    • pp.112-117
    • /
    • 2015
  • Mechanical properties of nonwoven alfa fiber based reinforced biocomposite were evaluated to assess the possibility of using it as a new material in engineering applications such as orthopedic application. Samples were fabricated by needle punching, thermal bonding and Hydroentanglement, by blending alfa fibers with wool fibers or Polypropylene fibers. The mechanical properties were tested and showed that the nonwoven NW3 (alfa fiber/PP/PLA, with hydroentanglement) is the best. It has a value of stress at break of 1.94 MPa, a strain of 54.2% and a young's module of 7.95 MPa, in a production normal direction. A biocomposite has been made with NW3 mixed with PMMA matrix. The use of nonwoven based alfa fiber in reinforcing the composite material increases its rigidity and the tensile strength; the elongation was found to be 1.53%, the Young's Module of 1.79 GPa and the tensile at break of 15.06 MPa. Results indicated that alfa fibres are of interest for low-cost engineering applications and can compete with glass fibres in orthopedic application.

가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석 (The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement)

  • 김덕근;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF