• 제목/요약/키워드: direct tensile strength test

검색결과 124건 처리시간 0.025초

Direct Tensile Test of GFRP Bar Reinforced Concrete Prisms

  • Choi Dong-Uk;Lee Chang-Ho;Ha Sang-Su
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.323-326
    • /
    • 2005
  • Uniaxial tension test of Glass Fiber Reinforced Polymer (GFRP) bar reinforced concrete prisms was performed. The objective was to investigate the adequate cover thickness of the GFRP rebars. The tension stiffening effect of GFRP bar reinforced concrete was also studied. The test variables included rebar types (conventional steel rebar and two different GFRP rebars) and cover thicknesses (five different cover thicknesses ranging between 1-3db). Normal strength concrete was used. Cracking patterns on concrete surface and cracking loads were careful1y observed during the direct tensile test. The test results indicated that the adequate cover thickness of the GFRP rebars may even be larger than that of the steel rebars and that the cover thickness of 2db commonly specified for the GFRP rebars may not be large enough. The tension stiffening effect of the GFRP rebars was also quantified and documented from the test results.

  • PDF

신장계에 의한 소성변형비 자동측정법의 평가에 관한 연구 (A Study on the Evaluation of the Automatic Measurement Method of Plastic Strain Ratio by Two Extensometers)

  • 김인수
    • 소성∙가공
    • /
    • 제12권5호
    • /
    • pp.504-512
    • /
    • 2003
  • The plastic strain ratios(R-values) of low carbon steel sheets were determined by the automatic strain measurement method using two extensometers, the indirect photo method for the same tensile specimen during tensile test and the indirect method for the specimen after tensile test. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method using two extensometers coincided with those from the indirect photo method and the indirect method for all tensile specimens. In addition, the strain dependence of plastic strain ratios could be continuously recorded and the anisotropy of the strength coefficient, K, and strain hardening exponent, n, could be automatically calculated in three directions by computer through the use of two extensometers. The experimental results showed that the strain dependence of R-value was related to the anisotropy of strain hardening exponent in low carbon steel sheets.

Investigation of the tensile behavior of joint filling under experimental test and numerical simulation

  • Fu, Jinwei;Haeri, Hadi;Sarfarazi, Vahab;Marji, Mohammad Fatehi;Guo, Mengdi
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.243-258
    • /
    • 2022
  • In this paper, tensile behavior of joint filling has been investigated under experimental test and numerical simulation (particle flow code). Two concrete slabs containing semi cylinder hole were prepared. These slabs were attached to each other by glue and one cubic specimen with dimension of 19 cm×15 cm×6 cm was prepared. This sample placed in the universal testing machine where the direct tensile stress can be applied to this specimen by implementing a special type of load transferring device which converts the applied compressive load to that of the tensile during the test. In the present work, two different joint filling thickness i.e., 3 mm and 6 mm were prepared and tested in the laboratory to measure their direct tensile strengths. Concurrent with experimental test, numerical simulation was performed to investigate the effect of hole diameter, length of edge notch, filling thickness and filling length on the tensile behavior of joint filling. Model dimension was 19 cm×15 cm. hole diameter was change in four different values of 2.5 cm, 5 cm, 7.5 cm and 10 cm. glue lengths were different based on the hole diameter, i.e., 12.5 cm for hole diameter of 2.5 cm, 10 cm for hole diameter of 5 cm, 7.5 cm for hole diameter of 7.5 cm and 5 cm for hole diameter of 10 cm. length of edge notch were changed in three different value i.e., 10%, 30% and 50% of glue length. Filling thickness were changed in three different value of 3 mm, 6 mm and 9 mm. Tensile strengths of glue and concrete were 2.37 MPa and 6.4 MPa, respectively. The load was applied at a constant rate of 1 kg/s. Results shows that hole diameter, length of edge notch, filling thickness and filling length have important effect on the tensile behavior of joint filling. In fixed glue thinks and fixed joint length, the tensile strength was decreased by increasing the hole diameter. Comparing the results showed that the strength, failure mechanism and fracture patterns obtained numerically and experimentally were similar for both cases.

지반보강재로서 타이어 트레드의 공학적 특성 (Engineering Properties of Tire Treads for Soil Reinforcement)

  • 윤여원;조성수;김근수
    • 한국지반환경공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.49-55
    • /
    • 2007
  • 폐타이어의 트레드를 지반보강재로서 활용하기 위해서는 타이어 외면 및 내면과 흙간의 내부마찰각 그리고 폐타이어 연결부의 강도특성을 알아야 한다. 본 연구에서는 폐타이어 트레드와 모래 및 풍화토간의 접촉면마찰각을 알기 위해 흙의 다짐정도를 달리하여 대형직접전단시험을 수행하였다. 직접전단시험 결과 모래-타이어 외면간의 마찰각비(${\delta}/{\phi}$)는 1.06배 이상, 모래-트레드 내면간의 ${\delta}/{\phi}$는 0.93배 이상, 풍화토의 마찰각비(${\delta}/{\phi}$)는 트레드 외면과 내면에 대하여 각각 0.98, 0.92로 나타났다. 또한 UTM을 이용하여 폐타이어 연결부의 재료에 따른 인장강도시험을 수행하였다. 시험 결과 고장력 볼트를 사용한 인장시험에서 볼트의 개수 및 와셔의 크기가 증가할수록 연결부에서의 인장강도는 증가하였으며 폴리프로필렌 로프 연결의 경우가 볼트연결의 경우보다 작은 강도를 나타내었다.

  • PDF

실리콘 직접 접합을 위한 선형가열법의 개발 및 SOI 기판에의 적용 (Development of Linear Annealing Method for Silicon Direct Bonding and Application to SOI structure)

  • 이진우;강춘식;송오성;양철웅
    • 한국표면공학회지
    • /
    • 제33권2호
    • /
    • pp.101-106
    • /
    • 2000
  • SOI (Silicon-On-Insulator) substrates were fabricated with varying annealing temperature of $25-660^{\circ}C$ by a linear annealing method, which was modified RTA process using a linear shape heat source. The annealing method was applied to Si ∥ $SiO_2$/Si pair pre-contacted at room temperature after wet cleaning process. The bonding strength of SOI substrates was measured by two methods of Razor-blade crack opening and direct tensile test. The fractured surfaces after direct tensile test were also investigated by the optical microscope as well as $\alpha$-STEP gauge. The interface bonding energy was 1140mJ/m$^2$ at the annealing temperature of $430^{\circ}C$. The fracture strength was about 21MPa at the temperature of $430^{\circ}C$. These mechanical properties were not reported with the conventional furnace annealing or rapid thermal annealing method at the temperature below $500^{\circ}C$. Our results imply that the bonded wafer pair could endure CMP (Chemo-Mechanical Polishing) or Lapping process without debonding, fracture or dopant redistribution.

  • PDF

강섬유 보강 초고성능 콘크리트(UHPFRC) I형 보의 전단 강도 (Shear Strength of Ultra-High Performance Fiber-Reinforced Concrete(UHPFRC) I-shaped Beams without Stirrup)

  • 이지형;홍성걸
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.53-64
    • /
    • 2017
  • 강섬유 보강 초고성능 콘크리트(UHPFRC)는 높은 압축강도 뿐 아니라 강섬유 보강에 의한 뛰어난 응력분산효과로 인해 높은 인장강도를 가지며, 미세균열의 확장을 통해 균열 후에도 경화거동을 하여 구조부재가 안정적으로 외력에 저항하도록 한다. 본 연구에서는 UHPFRC 재료 인장강도를 정의함에 있어 노치가 있는 휨실험과 직접인장실험을 비교하여 실험법 및 결과 분석의 장단점을 알아보았다. I-형 보의 전단부재실험은 복부의 면내전단거동을 알아보기 위하여 전단 경간비, 유효높이, 재료인장강도를 변수로 계획하였다. 실험결과를 통해 전단보강근이 없는 UHPFRC I형 보의 균열발생 이후 전단거동의 응력 재분배효과를 정량적으로 판단하고, 균열 후 거동을 기존 전단 강도식이 잘 반영하고 있는지 검토하였다. 전단철근 보강이 없는 UHPFRC 전단부재의 경우 파괴모드는 사인장 파괴로 동일하였고, 이러한 파괴모드를 가지는 부재는 전단 경간비와 유효높이에 크게 영향을 받게 되어 부재 설계 시 이러한 변수에 대한 고려가 필요한 것으로 나타났다.

콘크리트의 기건 단위질량을 고려한 인장강도 예측모델 제안 (A Proposal of Tensile Strength Prediction Models Considering Unit Weight of Concrete)

  • 심재일;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.107-115
    • /
    • 2012
  • 본 연구에서는 경량 콘크리트에 대한 361개, 보통중량 콘크리트에 대한 1,335개 및 고중량 콘크리트에 대한 221개의 데이터를 이용하여 콘크리트의 인장강도 (직접인장강도, 쪼갬인장강도 및 파괴계수)에 대한 설계기준과 기존 연구자들의 제안모델의 안정성을 평가하였다. 콘크리트 인장강도 예측을 위한 대부분의 제안 식들은 보통중량 콘크리트의 실험결과를 이용하여 압축강도의 함수로서 제시되었다. 하지만 데이터베이스의 분석은 콘크리트 인장강도는 기건 단위질량에 의해서도 중요한 영향을 받음을 보여준다. 이에 따라, 콘크리트 인장강도에 대한 기준 및 제안모델들은 기건 단위질량 2,100 $kg/m^3$ 이하, 압축강도 50 MPa 이상에서는 실험결과와의 불일치가 증가하였다. 한편, 본 연구에서 콘크리트 기건 단위질량을 고려하여 제시된 콘크리트 인장강도 예측 모델들은 실험결과와 비교적 잘 일치하였다.

Tension Stiffening Effect of High-Strength Concrete in Axially Loaded Members

  • Kim, Woo;Lee, Ki-Yeol;Yum, Hwan-Seok
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.915-923
    • /
    • 2003
  • This paper presents the test results of total 35 direct tensile specimens to investigate the effect of high-strength concrete on the tension stiffening effect in axially loaded reinforced concrete tensile members. Three kinds of concrete strength 25, 60, and 80 MPa were included as a major experimental parameter together with six concrete cover thickness ratios. The results showed that as higher strength concrete was employed, not only more extensive split cracking along the reinforcement was formed, but also the transverse crack space became smaller. Thereby, the effective tensile stiffness of the high-strength concrete specimens at the stabilized cracking stage was much smaller than those of normal-strength concrete specimens. This observation is contrary to the current design provisions, and the significance in reduction of tension stiffening effect by employment of high-strength concrete is much higher than that would be expected. Based on the present results, a modification factor is proposed for accounting the effect of the cover thickness and the concrete strength.

고기능 소재용 마이크로 인장시험기 개발 (Development of Micro Tensile Tester for High Functional Materials)

  • 최현석;한창수;최태훈;이낙규;임성주;박훈재;김승수;나경환
    • 소성∙가공
    • /
    • 제11권7호
    • /
    • pp.561-568
    • /
    • 2002
  • Micro tensile test is the most direct and convenient method to measure material properties such as Young's modulus and fracture strength. It, however, needs more accurate measurement system, mote stable and repetitive alignment and more sensitive gripping than conventional tensile test. Many researchers have put their effort on overcoming these difficulties for tile development of micro tensile tester, fabricating micro specimens of functional materials and measuring their properties. This paper will review the related vigorous researches over the world in the recent decade and explain how to apply them to a design of the fester which is under our own development.

Nd:YAG 레이저를 이용한 비정질 박판 용접부의 파괴에 대한 실험적 연구 (An experimental study on the fracture of Nd:YAG laser welded amorphous foils)

  • 이건상
    • 한국레이저가공학회지
    • /
    • 제3권3호
    • /
    • pp.31-37
    • /
    • 2000
  • In this paper, the possibilities of the laser overlap spot welding were studied to utilize the advantageous properties of amorphous metal foils. In order to estimate the usage of amorphous metals foils as structural members, the tensile shear strength and the fracture features were investigated. Although the crystalline zone on the surface was formed, it was not the direct cause of the fracture of the weld. The fracture of the weld resulted from the geometry discontinuity between the workpiece and the protrusion zone, which was formed during the weld process. The vein pattern - the typical feature of the fracture of the amorphous metal - was formed on the fracture surface. The tensile shear stress was reached to 1200 N/㎟ (2-foils overlap welding) and 900 N/㎟ (10-foils overlap welding), whereas the tensile strength of the workpiece was 1500-2000 N/㎟.

  • PDF