• Title/Summary/Keyword: direct limit

Search Result 474, Processing Time 0.036 seconds

Development of Sound Design Strategies for Promoting Self-regulated Learning Behaviors in Mobile Learning Environments

  • KIM, Taehyun
    • Educational Technology International
    • /
    • v.13 no.1
    • /
    • pp.101-144
    • /
    • 2012
  • Students mostly precede their learning without any direct support of instructor in e-learning and mobile educational environment. Many useful strategies and tools to facilitate self-regulated learning behaviors in e-learning environment have been introduced, yet, the limit has been reached by only suggesting self-regulated strategies with visual information in the most researches. Accordingly, this research is intent to propose the sound design strategies that facilitate learner's self-regulated learning behaviors in mobile learning environment. To achieve the objective of the research, two research questions are presented. First, what are the sound design strategies that facilitate the self -regulated learning behaviors in mobile learning environment?. Second, what are the results of evaluating the developed sound design strategies in terms of facilitating self-regulated learning behaviors?. To solve these research questions, the literature reviews on characteristics of mobile learning, concepts and features of self-regulated learning and sound were done to establish the sound design strategies. Through formative research method targeting instructional designers, sound design strategies were modified and supplemented. The research to validate these was performed and to verify the effect of the derived sound design strategies, the usability test aimed at instructional designer and learners was conducted. The final sound design strategies through this research process were six general design strategies and the sixteen detailed strategies. This research is meaningful because this offers the basic research on sound information design which has been lacking and help upgrade the upper limit of instructional design which mainly focused on visual information in mobile learning environment that shows information in a small screen.

A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process (LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구)

  • Kim, JoonBeom;Kang, Joon Hyuk;Chung, Eun-Kyo;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.

Scattering characteristics of metal and dielectric optical nano-antennas

  • Ee, Ho-Seok;Lee, Eun-Khwang;Song, Jung-Hwan;Kim, Jinhyung;Seo, Min-Kyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.76.1-76.1
    • /
    • 2015
  • Optical resonances of metallic or dielectric nanoantennas enable to effectively convert free-propagating electromagnetic waves to localized electromagnetic fields and vice versa. Plasmonic resonances of metal nanoantennas extremely modify the local density of optical states beyond the optical diffraction limit and thus facilitate highly-efficient light-emitting, nonlinear signal conversion, photovoltaics, and optical trapping. The leaky-mode resonances, or termed Mie resonances, allow dielectric nanoantennas to have a compact size even less than the wavelength scale. The dielectric nanoantennas exhibiting low optical losses and supporting both electric and magnetic resonances provide an alternative to their metallic counterparts. To extend the utility of metal and dielectric nanoantennas in further applications, e.g. metasurfaces and metamaterials, it is required to understand and engineer their scattering characteristics. At first, we characterize resonant plasmonic antenna radiations of a single-crystalline Ag nanowire over a wide spectral range from visible to near infrared regions. Dark-field optical microscope and direct far-field scanning measurements successfully identify the FP resonances and mode matching conditions of the antenna radiation, and reveal the mutual relation between the SPP dispersion and the far-field antenna radiation. Secondly, we perform a systematical study on resonant scattering properties of high-refractive-index dielectric nanoantennas. In this research, we examined Si nanoblock and electron-beam induced deposition (EBID) carbonaceous nanorod structures. Scattering spectra of the transverse-electric (TE) and transverse-magnetic (TM) leaky-mode resonances are measured by dark-field microscope spectroscopy. The leaky-mode resonances result a large scattering cross section approaching the theoretical single-channel scattering limit, and their wide tuning ranges enable vivid structural color generation over the full visible spectrum range from blue to green, yellow, and red. In particular, the lowest-order TM01 mode overcomes the diffraction limit. The finite-difference time-domain method and modal dispersion model successfully reproduce the experimental results.

  • PDF

A Phytoclimatic Review of Warm-temperate Vegetation Zone of Korea (한국 난온대 식생분포대의 식물기후학적 재검토)

  • Eom, Byeongcheol;Kim, Jong-Won
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.2
    • /
    • pp.195-207
    • /
    • 2020
  • In Korea, specific thermal elements such as annual mean temperature (AMT) 13℃, 14℃, and Kira's coldness index (CI) -10℃, have been suggested about the northernmost distribution of the warm-temperate evergreen broad-leaved forest zone. We reviewed the relationship between three thermal elements and the actual distribution of evergreen broad-leaved woody plants or its communities. Thiessen and Kriging method using point-data calibrated by seasonal lapse rate according to altitude were utilized for the spatial distribution pattern analysis. Several phytoclimatic maps were also produced in order to compare different thermal values. We identified that the AMT 13℃ was the best thermal element to demarcate the northern limit of the warm-temperate forest zone. Its area was estimated ca. 20,334 ㎢ and larger than those of other thermal elements. We concluded that an indirectly fabricated index i.e. CI -10℃ is useless and it was enough for a direct value of AMT 13℃ to represent the northern-limit distribution of warm-temperate forest zone, at least in Korea. Further researches on the reciprocity between floristic regions and phytoclimate zones are raised.

Work Environments and Exposure to Hazardous Substances in Korean Tire Manufacturing

  • Lee, Na-Roo;Lee, Byung-Kyu;Jeong, Si-Jeong;Yi, Gwang-Yong;Shin, Jung-Ah
    • Safety and Health at Work
    • /
    • v.3 no.2
    • /
    • pp.130-139
    • /
    • 2012
  • Objectives: The purpose of this study is to evaluate the tire manufacturing work environments extensively and to identify workers' exposure to hazardous substances in various work processes. Methods: Personal air sampling was conducted to measure polycyclic aromatic hydrocarbons, carbon disulfide, 1,3-butadiene, styrene, methyl isobutyl ketone, methylcyclohexane, formaldehyde, sulfur dioxide, and rubber fume in tire manufacturing plants using the National Institute for Occupational Safety Health Manual of Analytical Methods. Noise, carbon monoxide, and heat stress exposure were evaluated using direct reading instruments. Past concentrations of rubber fume were assessed using regression analysis of total particulate data from 2003 to 2007, after identifying the correlation between the concentration of total particulate and rubber fume. Results: Workers were exposed to rubber fume that exceeded 0.6 mg/$m^3$, the maximum exposure limit of the UK, in curing and production management processes. Forty-seven percent of workers were exposed to noise levels exceeding 85 dBA. Workers in the production management process were exposed to $28.1^{\circ}C$ (wet bulb globe temperature value, WBGT value) even when the outdoor atmosphere was $2.7^{\circ}C$ (WBGT value). Exposures to other substances were below the limit of detection or under a tenth of the threshold limit values given by the American Conference of Governmental Industrial Hygienists. Conclusion: To better classify exposure groups and to improve work environments, examining closely at rubber fume components and temperature as risk indicators in tire manufacturing is recommended.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).

Postbuckling strength of an axially compressed elastic circular cylinder with all symmetry broken

  • Fujii, Fumio;Noguchi, Hirohisa
    • Structural Engineering and Mechanics
    • /
    • v.11 no.2
    • /
    • pp.199-210
    • /
    • 2001
  • Axially compressed circular cylinders repeat symmetry-breaking bifurcation in the postbuckling region. There exist stable equilibria with all symmetry broken in the buckled configuration, and the minimum postbuckling strength is attained at the deep bottom of closely spaced equilibrium branches. The load level corresponding to such postbuckling stable solutions is usually much lower than the initial buckling load and may serve as a strength limit in shell stability design. The primary concern in the present paper is to compute these possible postbuckling stable solutions at the deep bottom of the postbuckling region. Two computational approaches are used for this purpose. One is the application of individual procedures in computational bifurcation theory. Path-tracing, pinpointing bifurcation points and (local) branch-switching are all applied to follow carefully the postbuckling branches with the decreasing load in order to attain the target at the bottom of the postbuckling region. The buckled shell configuration loses its symmetry stepwise after each (local) branch-switching procedure. The other is to introduce the idea of path jumping (namely, generalized global branch-switching) with static imperfection. The static response of the cylinder under two-parameter loading is computed to enable a direct access to postbuckling equilibria from the prebuckling state. In the numerical example of an elastic perfect circular cylinder, stable postbuckling solutions are computed in these two approaches. It is demonstrated that a direct path jump from the undeformed state to postbuckling stable equilibria is possible for an appropriate choice of static perturbations.

Control of HVDC-MMC Considering the Switching Device's Current Capacity and Circulating Current under Unbalanced Voltage Conditions (불평형 전압 조건에서 스위칭 소자의 전류 용량과 순환전류를 고려한 HVDC-MMC 제어기법)

  • Moon, Ji-Woo;Pae, Deuk-Woo;Park, Jung-Woo;Kang, Dea-Wook;Yoo, Dong-Wook;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • This paper proposes a control method for high voltage direct current(HVDC) with modular multilevel converter (MMC) under unbalanced voltage conditions considering the submodule(SM)'s current capacity and circulating current. It is aimed to propose a control method in which the current peak value does not exceed the maximum value of HVDC-MMC by considering the current capacity of the SM under unbalance voltage conditions. And it analyzes the effect of the unbalanced voltage on circulating currents in MMC and then proposes a control method considering each component of circulating currents under unbalanced voltages. The effectiveness of the proposed controlling method is verified through simulation results using PSCAD/EMTDC.

A CLINICAL EVALUATION ON THE DESIGN OF REMOVABLE PARTIAL DENTURE (국부의치 설계에 관한 임상적 연구)

  • Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.66-71
    • /
    • 1976
  • The purpose of this investigation was to evaluate the mouth preparation and design of removable partial dentures. A total of 187cases for the prefabricated partial denture frameworks in both maxillary and mandibular semi-dentulous situations (66 cases and 203 cases) was selected from this study. The evaluations of mouth preparation and design observed here involved the classification of edentulous spaces, status of abutment splinting with location, design of direct retainer and structure of maxillary major connector according to the incidence of both dental arches, ages, sexes and segment of semidentulousness. The analyzed results were as follows: 1) The order of frequency rate in removable partial denture construction was Class II (50.27%), Class I (36. 90%), Class III (10.69%), and Class IV (2.14 %). 2) The distribution on design of maxillary removable partial denture prosthesis was 33.22% and 64.11% in mandibular removable partial denture prosthesis. 3) The age distribution of removable partial denture prosthesis was prominent after40 years (41.71%). 4) The design pattern of maxillary major connectors was in order of anteroposterior bar, single palatal bar, palatal strap, U-shape connector. 5) The design pattern of direct retainer was in order of Aker's clasp, I-bar clasp, backaction clasp, cuspid universal clasp. 6) The abutment for partial denture clasp splinted between premolar and premolar and its frequency rate revealed 53.44%. 7) It seemed that the location and design of the indirect retainer showed accepatble limit.

  • PDF

Quantitation of Hepatitis C Viral RNA Using Direct CRT-PCR

  • Park, Young-Suk;Lee, Kyung-Ok;Oh, Moon-Ju;Chai, Young-Gyu
    • BMB Reports
    • /
    • v.30 no.3
    • /
    • pp.234-236
    • /
    • 1997
  • Chronic hepatitis C virus (HCV) infection is associated with the rapid development of cirrhosis and hepatocellular carcinoma. It has been reported that the amount of HCV RNA may be correlated with the progression of hepatitis and may be a prognostic marker for treatment of HCV patients. The direct detection of HCV RNA by reverse transcription-polymerase chain reaction (RT-PCR) is widely used to determine the presence of circulating virions. The most relevant limit of this approach is the lack of quantitative information about the viral titer. In the present study, we developed the method for HCV quantitation using competitive reverse transcription (CRT)-PCR using the deleted HCV standard. The serially diluted standard was added in titrated amounts to the target HCV RNA. The mixture was then reverse transcribed and amplified in the same reaction tube. The methods were evaluated using over 110 HCV-PCR positive samples in Koreans. About 59% of the samples were judged to contain $10^{5}-10^{6}$ copies of HCV RNA in 1 ml of serum.

  • PDF