• Title/Summary/Keyword: direct comparison

Search Result 1,579, Processing Time 0.029 seconds

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.

Comparison of Growth Increment and Ginsenoside Content in Different Parts of Ginseng Cultivated by Direct Seeding and Transplanting (직파와 이식재배에 따른 인삼의 부위별 생육특성 및 진세노사이드 함량 비교)

  • Li, Xiangguo;Kang, Sun-Joo;Han, Jin-Soo;Kim, Jung-Sun;Choi, Jae-Eul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.2
    • /
    • pp.70-73
    • /
    • 2010
  • This study was carried out to clarify the difference of growth characteristics and ginsenoside content in 5-year-old ginseng root grown by direct seeding and transplanting cultivation. Root weight per plant of direct seeding cultivation was lower than that of transplanting cultivation. Fresh and dry matter partitioning ratio of direct seeding cultivation was high in main root and low in lateral because direct seeding cultivation root elongated the length of main root, while it suppressed the growth of lateral root. Total amount of ginsenoside contents by direct seeding and transplanting cultivation were 362.8 and 320.3 mg in main root, 188.6 and 548.8 mg in lateral root, 170.7 and 273.8 mg in fine root. Its contents of whole root per plant were 722.1 and 1142.9 mg by direct seeding and transplanting, respectively.

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Comparing the Questionnaires for Classifying Quality Attributes in the Kano Model (Kano 모델의 품질속성 분류를 위한 질문서 연구)

  • Kim, Man-Ho;Song, HaeGeun;Park, Young T.
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.2
    • /
    • pp.209-220
    • /
    • 2013
  • Purpose: This paper compares and discusses the influence on the quality classification of Kano's questionnaire which is used for the Kano model(Kano et al., 1984), the 3-point Likert-scale newly proposed by Kano and the 5-point Likert-scale presented in this study. Methods: For the comparison, the current study conducts a survey of 631 television viewers. The classification results of the three methods are then compared with those of direct classification which is adopted as a standard for classification of quality attributes. Results: The agreement rates between the results using conventional Kano's questionnaire and the results using direct classification is higher than the results using 3-point and 5-point Likert-scales. In addition, the attributes grouped as must-be or attractive in the direct classification appear to be classified as one-dimensional attributes in the Likert-scales. Conclusion: In comparison with the convensional Kano's questionnaire, the Likert-scale questions highly tend to classify the quatity attributes as one-dimensional. Although the classification results of the 3-point and 5-point Likert-scales are the same, the 5-point Likert-scale has the advantage to classify quality attributes in more detail.

Comparison Study of Long-haul 100-Gb/s DDO-OFDM and CO-OFDM WDM Systems

  • Liu, Ling;Xiao, Shilin;Bi, Meihua;Zhang, Lu
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-562
    • /
    • 2016
  • In this paper, for the first time, the transmission performances of long-haul 100-Gb/s direct detection optical OFDM (DDO-OFDM) and coherent optical OFDM (CO-OFDM) wavelength division multiplexing (WDM) systems are compared by simulation. It provides specific guides for system parameter selection to get a high-performance and cost-effective OFDM WDM system. Specifically, the comparison involves three aspects: launched power is investigated to achieve better system performance; laser linewidth is numerically investigated to choose cost-effective laser; system dispersion tolerances with different laser linewidths are analyzed to further reveal the advantages and disadvantages of these two detecting methods, direct detection and coherent detection, in long-haul OFDM WDM system.

Application of KORSLE to Estimate Soil Erosion at Field Scale (한국형 토양유실공식에 의한 토양유실량 현장예측)

  • Song, Jae Min;Yang, Jae E;Lim, Kyoung Jae;Park, Youn Shik
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.5
    • /
    • pp.31-41
    • /
    • 2019
  • In 2013, the Ministry of Environment in South Korea promulgated a new regulatory bulletin that contained revised enforcement ordinance on soil management protocols. The bulletin recommends the use of Universal Soil Loss Equation (USLE) for the soil erosion estimation, but USLE has limited applicability in prediction of soil erosion because it does not allow direct estimation of actual mass of soil erosion. Therefore, there is a great need of revising the protocol to allow direct comparison between the measured and estimated values of soil erosion. The Korean Soil Loss Equation (KORSLE) was developed recently and used to estimate soil loss in two fields as an alternative to existing USLE model. KORSLE was applied to estimate monthly rainfall erosivity indices as well as temporal variation in potential soil loss. The estimated potential soil loss by KORSLE was adjusted with correction factor for direct comparison with measured soil erosion. The result was reasonable since Nash-Stucliff efficiency were 0.8020 in calibration and 0.5089 in validation. The results suggest that KORSLE is an appropriate model as an alternative to USLE to predict soil erosion at field scale.

Determining the Importance Values of Quality Attributes Using ASC (ASC를 이용한 품질특성의 중요도 결정)

  • Jang, Heung-Yeop;Song, HaeGeun;Park, Young T.
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.4
    • /
    • pp.589-598
    • /
    • 2012
  • Purpose: Determination of the importance values of quality attributes is very important to integrate the Kano model with QFD. A new method to determine the importance values of quality attributes is proposed. Methods: ASC(Average Satisfaction Coefficient) is proposed in order to determine the importance values of quality attributes. To evaluate the effectiveness of ASC, a case study of modern TV sets is conducted, and the performance of ASC is compared with direct importance evaluation and AHP pairwise comparisons. Results: The result of ASC application is similar with those of direct importance evaluation and AHP pairwise comparison. Conclusion: ASC is an effective instrument to determine the importance values of quality attributes. It doesn't need a cumbersome process like AHP pairwise comparison, and can be calculated using the data for the conventional Kano model.

Comparison of Voltage Oriented Control and Direct Power Control under Command Mode Transition for PMSG Wind Turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.173-174
    • /
    • 2016
  • This paper proposes a comparison of Voltage Oriented Control (VOC) and Direct Power Control (DPC) under command mode transition for PMSG Wind Turbines (WT). Based on a neutral point clamped three level back to back type Voltage Source Converter (VSC), proposed control scheme automatically control the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. Automatic command mode transition based on the dc-link voltage error provides a command mode changing between grid command and MPPT mode. It is confirmed through PLECS simulations in Matlab. Simulation result shows that proposed control scheme of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control scheme of MPPT with optimal torque control and VOC under a step response. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG wind turbines in order to generate a high quality output power.

  • PDF

Comparison of Nonparametric Function Estimation Methods for Discontinuous Regression Functions

  • Park, Dong-Ryeon
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.6
    • /
    • pp.1245-1253
    • /
    • 2010
  • There are two main approaches for estimating the discontinuous regression function nonparametrically. One is the direct approach, the other is the indirect approach. The major goal of the two approaches are different. The direct approach focuses on the overall good estimation of the regression function itself, whereas the indirect approach focuses on the good estimation of jump locations. Apparently, the two approaches are quite different in nature. Gijbels et al. (2007) argue that the comparison of two approaches does not make much sense and that it is even difficult to choose an appropriate criterion for comparisons. However, it is obvious that the indirect approach also has the regression curve estimate as the subsidiary result. Therefore it is necessary to verify the appropriateness of the indirect approach as the estimator of the discontinuous regression function itself. Park (2009a) compared the performance of two approaches through a simulation study. In this paper, we consider a more general case and draw some useful conclusions.

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF