• 제목/요약/키워드: diode laser

검색결과 1,017건 처리시간 0.031초

저강도레이저 조사가 근육압좌손상 후 척수분절의 EGF 발현에 미치는 영향 (Effects of Low Power Laser for the Expression of EGF after Muscle Crush Injury)

  • 김석범;김동현;남기원;이선민;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제14권2호
    • /
    • pp.16-25
    • /
    • 2002
  • Low energy laser irradiation(LELI) therapy in physical therapy is widespread but the mechanisms are not fully understood. The purpose of the present study was to examine the epidermal growth factor(EGF)'s expression within lumbar spinal cord which corresponding with crushed extensor digitorum longus(EDL) of rats after low-power laser irradiation applied. After a crushed injury on the right EDL, low-power laser irradiation was applied by using 2000mW, 2000Hz, 830nm GaAlAs(Gallium-aluminum-arsenide) semiconductor diode laser. The laser treatment was performed with 10 minutes daily for 3days. After EDL crush injury, EGF immunoreactive positive neurons in experimental group were progressively decreased from the first to third days. Especially 1 day subgroup is highly expressed in dorsal horn(Lamina I, II, III) and around of central cannal of spinal cord(Lamina VII). Control group was only expressed slightly at 3 days. This study suggests that LELI stimulate that release and migration of EGF in spinal cord, which distict to wound site, therfore promote wound healing of EDL crush injury.

  • PDF

레이저 기반의 광 무선충전 및 광 무선통신의 동시전송 (Simultaneous Transmission of Optical Wireless Power Transfer and Optical Wireless Communication using a Laser Diode)

  • 신재우;윤태욱;김성만
    • 한국전자통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.605-610
    • /
    • 2021
  • 현재까지 알려진 무선충전 방식 중에서 장거리에서 가장 효율이 좋은 방식은 레이저를 이용한 방식이다. 여기에 레이저를 이용한 무선통신 기술을 결합한다면 다양한 분야에 활용이 가능할 것이다. 이에 본 논문에서는 레이저를 이용한 무선충전 및 무선통신의 동시전송 기술에 관하여 연구하고 이에 대한 실험 결과를 보인다. 이 기술은 광 무선충전을 위해서 송신부에 전/광 변환을 위한 레이저 광원을 사용하고 수신부에는 광/전 변환을 위한 태양전지를 사용한다. 또한, 광 무선통신을 위해 해당 레이저 광신호에 반송파를 이용하여 신호를 송신하는 방식이다. 본 논문에서는 실험을 통해 100 mW 레이저 송신부와 태양전지 수신부를 이용하여 광 무선충전은 1.9 %의 DC-to-DC 효율을 보였으며, 무선 광통신은 전송거리가 15 m일때 최대 90 kbps의 전송속도를 보였다.

Enhanced Susceptibility of Human Squamous Cell Carcinoma to Photodynamic Therapy Combined with Administration of Cisplatin

  • 안진철
    • 대한의생명과학회지
    • /
    • 제14권2호
    • /
    • pp.83-89
    • /
    • 2008
  • We have compared the antitumor effect of photodynamic therapy (PDT), using 5-aminolevulinic acid (ALA) as the photosensitizer, combined with cisplatin (CDDP) on AMC-HN3 human squamous cell carcinoma. AMC-HN3 cells were cultured and then incubated with various concentrations of CDDP and ALA. 632 nm diode laser was given at $6.0J/cm^2$ followed by incubation for 24 hours. The evaluation of cell viability was done by MTT assay. In vivo CDDP was injected intraperitoneally 24 hours prior to PDT. The anti-tumor effects of each treatment were measured by tumor volume change. Cell viability were 44.29% for the cisplatin-mediated chemotherapy group $(6.25{\mu}g/ml)$, 77.22% for ALA-PDT group, and 15.06% for the Combination therapy group. In vivo, the antitumor effect of photodynamic therapy was enhanced by combination of Cisplatin-mediated chemotherapy. Photodynamic therapy combined with administration of Cisplatin appears to enhance antitumor effect and to be a useful treatment modality.

  • PDF

병진운동 강체의 온라인 5자유도 운동오차 측정시스템 설계 및 해석 (Synthesis of an On-Line 5 Degrees of Freedom Error Measurement System for Translational Motion Rigid Bodies)

  • 김진상;정성종
    • 한국정밀공학회지
    • /
    • 제15권5호
    • /
    • pp.93-99
    • /
    • 1998
  • Although laser interferometer measurement system has advantages of measurement range and accuracy, it has some disadvantages when measurement of multi degrees of freedom of motion are required. Because the traditional error measurement methods for geometric errors (two straightness and three angular errors) of a slide of machine tools measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric errors of a moving rigid body in real time processes, an on-line error measurement system for simultaneous detection of the five error components of a moving object is required. Using laser alignment technique and some optoelectronic components, an on-line measurement system with 5 degrees of freedom was developed for the geometric error detection in this study Performance verification of the system has been performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a slide of machine tools.

  • PDF

Improvement of self-mixing semiconductor laser range finder and its application to range-image recognition of slowly moving object

  • Suzuki, Takashi;Shinohara, Shigenobu;Yoshida, Hirofumi;Ikeda, Hiroaki;Saitoh, Yasuhiro;Nishide, Ken-Ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.388-393
    • /
    • 1992
  • An infrared range finder using a self-mixing laser diode (SM-LD), which has been proposed and developed by the Authors, can measure not only a range of a moving target but its velocity simultaneously. In this paper, described is that the precise mode-hop pulse train can be obtained by employing a new signal processing circuit even when the backscattered light returning into the SM-LD is much more weaker. As a result, the distance to a tilted square sheet made from aluminium or white paper, which is placed 10 cm through 60 cm from the SM-LD, is measured with accuracy of a few percent even when the tilting angle is less than 75 degrees or 85 degrees, respectively. And in this paper, described is the range-image recognition of a plane object under the condition of standstill. The output laser beam is scanned by scanning two plane mirrors-equipped with each stepping motor. And we succeeded in the acquisition of the range-image of a plane object in a few tens of seconds. Furthermore, described is a feasibility study about the range-image recognition of a slowly moving plane object.

  • PDF

Mid-infrared Continuous-wave Optical Parametric Oscillator with a Fan-out Grating MgO:PPLN Operating Up to 5.3 ㎛

  • Bae, In-Ho;Yoo, Jae-Keun;Lim, Sun Do;Kim, Seung Kwan;Lee, Dong-Hoon
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.577-582
    • /
    • 2019
  • We report on a continuous-wave (cw) optical parametric oscillator (OPO) optimized for mid-infrared emission above 5.0 ㎛. The OPO is based on a magnesium-oxide-doped periodically poled LiNbO3(MgO:PPLN) crystal with a fan-out grating design. A linear two-mirror cavity resonating both at the pump and signal wavelengths is stabilized to the pump laser by using the modified Pound-Drever-Hall (PDH) method. The idler wavelength is continuously tunable from 4.7 ㎛ up to 5.3 ㎛ by varying the poling period of the fan-out grating crystal. Pumped by a diode-pumped solid state (DPSS) laser with a power of 1.1 W at 1064 nm, the maximum idler output power is measured to be 5.3 mW at 4.8 ㎛. The output power above 5.0 ㎛ is reduced to the hundreds of ㎼ level due to increased absorption in the crystal, but is stable and strong enough to be measured with a conventional detector.

망막 촬영 장치 및 16 채널 영상 획득 장치 개발 (Development of Retina Photographing System and 16 Channels Image Acquisition System)

  • 양근호
    • 한국정보통신학회논문지
    • /
    • 제8권1호
    • /
    • pp.96-101
    • /
    • 2004
  • 망막 두께 측정은 망막을 3차원으로 촬영하고 고속으로 신호처리를 할 수 있는 시스템을 필요로 한다. 본 논문에서는 망막을 촬영하여 3차원 영상으로 구성하기 위한 촬영장치 및 16채널 고속 영상 획득 시스템 개발내용을 소개한다. 망막에 HeNe 레이저를 투사하여 망막에서 반사되어 돌아오는 레이저의 양을 array photo diode로 감지한 후에 이를 3차원으로 형상화함으로써 망막의 두께를 측정한다. 망막에 레이저를 투사하는 장치, APD 광 센서를 이용한 망막 영상화 장치, 16 채널 실시간 A/D 변환 장치 및 PCI 마스터 인터페이스 장치를 개발하였다.

논문 : 광섬유 센서를 이용한 변형률, 온도, 진동의 동시 측정 (Papers : Simultaneous Measurement of Strain , Temperature , and Vibration Using Fiber Optic Sensor)

  • 강현규;방형준;홍창선;김천곤
    • 한국항공우주학회지
    • /
    • 제30권1호
    • /
    • pp.44-48
    • /
    • 2002
  • 본 논문에서는 단일 광섬유 FBG/EFPI 복합 센서를 이용하여 변형률, 온도, 그리고 진동으 세 가지 물리량을 동시에 측정하는 방법에 대해 설명하였다. 변형률과 온도를 측정하기 위한 FBG/EFPI 센서 시스템과 진동을 감지하기 위한 EFPI 센서 시스템을 wavelength division multiplexer를 이용하여 하나의 시스템으로 결합하였다. FBG/EFPI 센서 시스템의 광원은 파장 이동 광섬유 레이저(WSFL)이며 EFPI 센서 시스템의 광원은 단파장 레이저 다이오드이다. 구성된 시스템을 이용하여 열챔버에서 알루미늄 보의 열변형률, 온도, 그리고 진동의 동시 측정을 수행하여 본 시스템의 유효성을 확인하였다.

비전센서와 구조화빔을 이용한 용접 형상 측정 시스템 (System for Measuring the Welding Profile Using Vision and Structured Light)

  • 김창현;최태용;이주장;서정;박경택;강희신
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.50-56
    • /
    • 2005
  • The robot systems are widely used in the many industrial field as well as welding manufacturing. The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot tracking, many kinds of contact and non-contact sensors are used. Recently, the vision is most popular. In this paper, the development of the system which measures the shape of the welding part is described. This system uses the line-type structured laser diode and the vision sensor. It includes the correction of radial distortion which is often found in the image taken by the camera with short focal length. The Direct Linear Transformation (DLT) method is used for the camera calibration. The three dimensional shape of the parent metal is obtained after simple linear transformation. Some demos are shown to describe the performance of the developed system.

  • PDF

680nm 파장에서 TbFeCo 광자기 기록매체의 동특성 (Dynamic characteristics of TbFeCo Magneto-Optical recording media at 680nm wavelength region)

  • 윤두원;연정;김명룡
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.558-563
    • /
    • 1995
  • Dynamic characteristics of TbFeCo magneto-optical recording media at 680nm wavelength region were studied by means of computer simulation of disc structure and optimization of process variables during sputter deposition. With the slightly reduced Kerr rotation angle due to the reduced wavelength of optical laser source, the improved recording density in TbFeCo magneto optical media showing the CNR greater than 50dB could be achieved by only adjusting the thickness of dielectric and the recording layers when the wavelength of light source is changed from 780nm to 680nm. In addition, the recording power margin of 5mW and the 2mW minimum recording power was realized, It was shown from the present study that the increase in laser power density demonstrated feasibility of low cost and low power laser diode with the reduced optimum recording power.

  • PDF