• Title/Summary/Keyword: digital subtraction angiography

Search Result 106, Processing Time 0.021 seconds

Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block

  • Park, Kibeom;Kim, Saeyoung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.109-114
    • /
    • 2019
  • Background: Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF. Methods: We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA. Results: Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels. Conclusion: During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.

Arteriovenous Malformation of the Scalp : Efficacy of Computed Tomography Angiography

  • Moon, Kang-Seok;Yoon, Seok-Mann;Shim, Jai-Joon;Yun, Il-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.396-398
    • /
    • 2005
  • We report a rare case of scalp arteriovenous malformation[AVM]. A 55-year-old woman presented with a pulsatile palpable mass on her left temporo-parietal scalp. She complained of insomnia because of bruit, which was audible when she lay on her left side. Computed tomography angiography[CTA] for the scalp vessel showed AVM on the left temporo-parietal region. Multiple enlarged arteries, such as the superficial temporal artery, posterior auricular artery, and occipital artery, were directly connected to the elongated dilated superficial temporal vein. Digital subtraction angiography also showed similar results. Fistulous portions were clearly delineated on both modalities. Surgical excision of the malformations, including feeding arteries and the draining vein, resulted in immediate relief of the symptoms. Usefulness of CTA in the diagnosis of vascular lesions on the scalp was emphasized.

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

Traumatic Pseudoaneurysm of the Superficial Temporal Artery diagnosed with 3-Dimensional Computed Tomography Angiography: Two Cases Report (3차원 컴퓨터단층촬영 혈관조영술을 이용하여 진단한 외상성 천측두동맥 가성동맥류의 치험례)

  • Kwon, Ho;Hwang, Dong Yeon;Jung, Sung-No;Yim, Young Min;Shin, Ok Ran
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.265-268
    • /
    • 2007
  • Purpose: Superficial temporal artery(STA) aneurysms are very rare and mostly occur as pseudoaneurysms secondary to trauma. Clinical diagnosis of STA pseudoaneurysm is based on a history of trauma or surgery to frontotemporal region, which presents with pulsatile mass. To confirm diagnosis, many imaging strategies can be used such as digital subtraction angiography, sonography, CT and MRI. But, these imaging modalities are invasive or inaccurate or expensive. Thus, we used 3D CT angiography to confirm STA aneurysm and to get accurate information. Methods: We have experienced two cases of pulsatile mass on the temporal area, suspected as STA pseudoaneurysms. On the basis of clinical information, we performed 3D CT angiography to get more accurate information about this pulsatile mass and to confirm diagnosis. On the basis of information from 3D CT angiography, we performed operation. Results: The lesions were diagnosed as pseudoaneurysm of superficial temporal artery by 3D CT angiography, and surgically resected safely without any complication on the basis of information from 3D CT angiography. 3D CT angiography was excellent diagnostic method for detecting STA pseudoaneurysms, and effectively showed many information about pseudoanerysms such as relationship between the aneurysms and surrounding structures, and its size. Conclusion: We could effectively diagnose and treat on the basis of information from 3D CT angiography. We present our cases with a brief review of the literature related to STA traumatic pseudoaneurysms.

Should Cerebral Angiography Be Avoided within Three Hours after Subarachnoid Hemorrhage?

  • An, Hong;Park, Jaechan;Kang, Dong-Hun;Son, Wonsoo;Lee, Young-Sup;Kwak, Youngseok;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.526-535
    • /
    • 2019
  • Objective : While the risk of aneurysmal rebleeding induced by catheter cerebral angiography is a serious concern and can delay angiography for a few hours after a subarachnoid hemorrhage (SAH), current angiographic technology and techniques have been much improved. Therefore, this study investigated the risk of aneurysmal rebleeding when using a recent angiographic technique immediately after SAH. Methods : Patients with acute SAH underwent immediate catheter angiography on admission. A four-vessel examination was conducted using a biplane digital subtraction angiography (DSA) system that applied a low injection rate and small volume of a diluted contrast, along with appropriate control of hypertension. Intra-angiographic aneurysmal rebleeding was diagnosed in cases of extravasation of the contrast medium during angiography or increased intracranial bleeding evident in flat-panel detector computed tomography scans. Results : In-hospital recurrent hemorrhages before definitive treatment to obliterate the ruptured aneurysm occurred in 11 of 266 patients (4.1%). Following a univariate analysis, a multivariate analysis using a logistic regression analysis revealed that modified Fisher grade 4 was a statistically significant risk factor for an in-hospital recurrent hemorrhage (p=0.032). Cerebral angiography after SAH was performed on 88 patients ${\leq}3$ hours, 74 patients between 3-6 hours, and 104 patients >6 hours. None of the time intervals showed any cases of intra-angiographic rebleeding. Moreover, even though the DSA ${\leq}3$ hours group included more patients with a poor clinical grade and modified Fisher grade 4, no case of aneurysmal rebleeding occurred during erebral angiography. Conclusion : Despite the high risk of aneurysmal rebleeding within a few hours after SAH, emergency cerebral angiography after SAH can be acceptable without increasing the risk of intra-angiographic rebleeding when using current angiographic techniques and equipment.

Image fusion technique using flat panel detector rotational angiography for transvenous embolization of intracranial dural arteriovenous fistula

  • Jai Ho Choi;Yong Sam Shin;Bum-soo Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.3
    • /
    • pp.253-259
    • /
    • 2023
  • Precise evaluation of the feeders, fistulous points, and draining veins plays a key role for successful embolization of intracranial dural arteriovenous fistulas (DAVF). Digital subtraction angiography (DSA) is a gold standard diagnostic tool to assess the exact angioarchitecture of DAVFs. With the advent of new image postprocessing techniques, we lately have been able to apply image fusion techniques with two different image sets obtained with flat panel detector rotational angiography. This new technique can provide additional and better pretherapeutic information of DAVFs over the conventional 2D and 3D angiographies. In addition, it can be used during the endovascular treatment to help the accurate and precise navigation of the microcatheter and microguidwire inside the vessels and identify the proper location of microcatheter in the targeted shunting pouch. In this study, we briefly review the process of an image fusion technique and introduce our clinical application for treating DAVFs, especially focused on the transvenous embolization.

전산화 감산 혈관조영술(DSA)의 임상적 응용

  • 한만청
    • 전기의세계
    • /
    • v.34 no.9
    • /
    • pp.537-540
    • /
    • 1985
  • 인체에 발생하는 여러 질환을 진단 및 치료하고 예후를 결정하는데 혈관의 분포 및 그 상태를 관찰하는 것은 극히 중요하다. 형관조영술의 진단적 기치 및 그 임상적 응용은 1950년대 부터 널리 인정되고 있다. 다만 조영제 주입에는 동맥의 천자 및 도관(Catheter)삽입이라는 비교적 침습적 방법에 의존하여 왔다. 최근 Computer의 도입으로 대표되는 전자기술의 발전 등으로 혈관 특히 동맥의 저농도 조영상을 전산처리로서 숫자화하여 증강, 가산 또는 감산시키는 기법이 개발되어 1970년대 후반에 이르러 임상적으로 응용되게 되었다. 이러한 전산화 감산 형과조영술(Digital Subtraction Angiography : DAS)은 종래의 혈관조영술의 기본 수기에 전산 시스템을 복합시킨 것으로 그 임상적 효과는 매우 큰 것이다.

  • PDF

Spinal Arteriovenous Fistula with Progressive Paraplegia after Spinal Anaesthesia

  • Baltsavias, Gerasimos;Argyrakis, Nikolaos;Matis, Georgios K.;Mpata-Tshibemba, Stephanie
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.106-109
    • /
    • 2014
  • A case of an iatrogenic spinal arteriovenous fistula with progressive paraplegia in a young woman is reported. The fistula was eventually created after repetitive lumbar punctures performed in the process of spinal anaesthesia. Her symptoms were progressed to paraplegia over a period of 2 years. The digital subtraction angiography demonstrated a single-hole fistula, involving the anterior spinal artery and vein. The lesion was occluded by embolization with immediate improvement. The potential mechanism is discussed.