• Title/Summary/Keyword: digital reference

Search Result 1,283, Processing Time 0.03 seconds

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

Development of a force measurement device for curling sweeping with load cells (로드셀을 이용한 컬링 스위핑 힘 측정 장치 개발)

  • Lee, Sangcheol;Kim, Taewhan;Kil, Sekee;Choi, Sanghyup
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.49-56
    • /
    • 2017
  • Curling sweeping is one of important motion to control the position of the curling stone, and sweeping speed and applied force to the broom pad are major research subjects. In this study, a device was developed to measure the force applied to the curling broom pad in curling sweeping motion, and two load cells were mounted between the broom pad and pad holder. Analog signals generated from the load cells were sampled about 300 times per second using a micro controller, and then converted to 10-bit digital signals. Calibration of the load cell and set up of regression equations to convert the measured electrical signals into mass (force) was done by three M1 class weights, and the developed system was designed as wearable device to minimize increasing of total weight of the broom. Same force was applied to the developed system and a force plate that was using as a reference force measurement system in field of sports, and the difference between the measured values were showed about $0.909{\pm}1.375N$(mean and standard deviation). The developed system could be applied other kinds of study which required force measurement function similar to sweeping motion.

Extension of MPEG-2 TS and MPEG-C Part 3 for Higher Quality Stereoscopic Video Broadcasting Service (고화질 스테레오스코픽 비디오 방송서비스를 위한 MPEG-2 전송스트림과 MPEG-C part 3의 확장 방안)

  • Kang, Jeon-Ho;Lee, Gil-Bok;Kim, Kyu-Heon;Cheong, Won-Sik;Yun, Kug-Jin
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.750-761
    • /
    • 2011
  • Currently, 3DTV technologies are being developed as the future services of the HD digital broadcast environment. As one of the various research topics to apply 3DTV technologies to the conventional broadcasting network, methods to configure stereoscopic videos are being studied. In this paper, we proposed a method to broadcast high quality stereoscopic videos based on analysis of a method to add a stereoscopic descriptor to the PMT of MPEG-2 transport streams and a method to transmit stereoscopic videos by the expansion of MPEG-C part 3 which are from precedent studies. The proposed technique maintains compatibility with conventional MPEG-2 transport streams by showing only reference video for models that do not support 3D broadcasting. Therefore, the compatibility between conventional broadcasting and stereoscopic videos should make this method useful when activating 3D services in the communications and broadcasting area

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Study on the Technical Security Factor for the Implementation of Secure DB System (안정적인 DB보안 시스템 구축을 위한 보안기술요소 분석에 관한 연구)

  • Yoon, Sun-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.143-152
    • /
    • 2014
  • This paper introduces Database security to prevent the rapidly increasing issue of private information leakage. The Database security examined in the paper separates into DB access control area and DB encryption area which further leads the paper to analyze the factors of the two areas and suggest necessary elements for creating stable Database security. In addition, the paper examines previous DB security programs by areas and analyzes pros and cons from the tested result. The experiment indicated that while DB access control presents less degradation and reduced the need to modify the existing DBMS since the access control operates at the end point of the network, DB encryption presented strength in protecting the data from unauthorized access. On the other hand, DB access control is less useful in preventing the attack in advance which leaves the log to enable tracking afterward while DB encryption can only be operated by limited types of Database and causes degradation due to system load and shows higher percentage of failure when creating the system. This paper examines characteristics of Database security areas in order to be used as a reference for institutions or companies seeking stable Database security.

Low-Complexity H.264/AVC Deblocking Filter based on Variable Block Sizes (가변블록 기반 저복잡도 H.264/AVC 디블록킹 필터)

  • Shin, Seung-Ho;Doh, Nam-Keum;Kim, Tae-Yong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.41-49
    • /
    • 2008
  • H.264/AVC supports variable block motion compensation, multiple reference images, 1/4-pixel motion vector accuracy, and in-loop deblocking filter, compared with the existing compression technologies. While these coding technologies are major functions of compression rate improvement, they lead to high complexity at the same time. For the H.264 video coding technology to be actually applied on low-end / low-bit rates terminals more extensively, it is essential to improve tile coding speed. Currently the deblocking filter that can improve the moving picture's subjective image quality to a certain degree is used on low-end terminals to a limited extent due to computational complexity. In this paper, a performance improvement method of the deblocking filter that efficiently reduces the blocking artifacts occurred during the compression of low-bit rates digital motion pictures is suggested. In the method proposed in this paper, the image's spatial correlational characteristics are extracted by using the variable block information of motion compensation; the filtering is divided into 4 modes according to the characteristics, and adaptive filtering is executed in the divided regions. The proposed deblocking method reduces the blocking artifacts, prevents excessive blurring effects, and improves the performance about $30{\sim}40%$ compared with the existing method.

Analysis of crown size and morphology, and gingival shape in the maxillary anterior dentition in Korean young adults

  • Song, Jae-Won;Leesungbok, Richard;Park, Su-Jung;Chang, Se Hun;Ahn, Su-Jin;Lee, Suk-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.315-320
    • /
    • 2017
  • PURPOSE. The aim of this investigation was to analyze the dimensions of clinical crowns and to classify the crown and the gingival type in the anterior teeth in Korean young adults. MATERIALS AND METHODS. Casts were obtained from 50 subjects ranging in age from 24 to 32. Measurements of length and width were made on the casts using a pair of digital calipers on the entire dentition. Crown thickness and papilla height were also measured and MDW/CL (mesiodistal width to clinical length) and CW/CL (cervical width to clinical length) ratios of the maxillary anterior teeth were calculated. The K-clustering method was used for CW/CL to classify the anterior tooth shape into three groups (tapered, ovoid, and square), and one-way analysis of variance and Duncan's post-hoc comparison were used to evaluate statistical significance between the groups. Pearson's correlation analysis was performed between tooth shape and papillary height (PH) to demonstrate the correlation between tooth shape and gingival morphological characteristics. RESULTS. The average length of the maxillary central incisors was 9.89 mm; the mesio-distal width was 8.54 mm; and the ratio of width/length was 0.86 in Korean young adults. The average bucco-palatal thickness of the central incisor was 3.14 mm at the incisal 1/3 aspect. Ovoid type was the most common tooth shape (48%), followed by square type (29%) and taper type (23%) in the central incisors of Korean young adults. Tooth shape and gingival type were correlated with each other. CONCLUSION. New reference data were established for tooth size in Korean young adults and the data show several patterns of tooth shape and gingival type. Clinicians should diagnose and treat based on these characteristics for better results in the Korean population.

Forest Thematic Maps and Forest Statistics Using the k-Nearest Neighbor Technique for Pyeongchang-Gun, Gangwon-Do (kNN 기법을 이용한 강원도 평창군의 산림 주제도 작성과 산림통계량 추정)

  • Yim, Jong-Su;Kong, Gee Su;Kim, Sung Ho;Shin, Man Yong
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.3
    • /
    • pp.259-268
    • /
    • 2007
  • This study was conducted to produce forest thematic maps and estimate forest statistics for Pyeongchang Gun using the kNN technique, which has been applied to produce thematic maps of variables of interest including unobserved plots by combining field plot data, remotely sensed data and other digital map data in forest inventories. The estimation errors for three horizontal reference areas (HRAs), whose radii are 20, 40 and 60 km respectively, were compared. Although the precision for the 40 km radius was lower compared to that for the 60 km radius, the 40 km radius was found to be an efficient HRA because their difference in precision was modest. At a value of k=5 nearest neighbors for the selected HRA, the overall accuracy was high. As a result, using the k=5 neighbors within the HRA of 40 km radius, thematic maps of number of trees, basal area, and growing stock per hectare were generated. As compared to the forest statistics based on field sample plots, the estimated means of each parameter from the produced maps were underestimated.

Application of Adaptive Loop Filter for NRT-Based Stereoscopic Video Coding (비실시간 기반 스테레오스코픽 비디오 부호화를 위한 적응루프필터 적용기법)

  • Lee, Byung-Tak;Lee, BongHo;Choi, Haechul;Kim, Jin-Soo;Yun, Kugjin;Cheong, Won-Sik;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.18 no.2
    • /
    • pp.261-270
    • /
    • 2013
  • A stereoscopic 3D video service is able to provide a 3D video service while keeping backward compatibility with the existing 2D video service. In the terrestrial digital television (DTV) system, a stereoscopic video codec is required to have high coding efficiency in order to provide a 3D video service in the same channel capacity. A hybrid codec consisting of MPEG-2 for base video and H.264/AVC or HEVC for 3D auxiliary video is considered. Furthermore, Non-Real-Time (NRT) delivery of stereoscopic video is also considered as a service scenario for 3DTV services to overcome the limited bandwidth. In this paper, we propose a stereoscopic video coding scheme using adaptive loop filter (ALF) which had been considered in HEVC as a pre-/post-filter for enhancing coding efficiency in NRT-based 3DTV services. In order to apply ALF as a post-filter to the reconstructed additional view coded by H.264/AVC, we devise a method in which ALF is adaptively applied based on a structure determined by using macroblock (MB) coding information such as MB mode type and reference index instead of coding unit (CU) structure on which ALF is applied in the HEVC. Experimental results shows that the proposed stereoscopic video coding scheme applying ALF obtains up to 24.9% gain of bit saving.

A Feature -Based Word Spotting for Content-Based Retrieval of Machine-Printed English Document Images (내용기반의 인쇄체 영문 문서 영상 검색을 위한 특징 기반 단어 검색)

  • Jeong, Gyu-Sik;Gwon, Hui-Ung
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.10
    • /
    • pp.1204-1218
    • /
    • 1999
  • 문서영상 검색을 위한 디지털도서관의 대부분은 논문제목과/또는 논문요약으로부터 만들어진 색인에 근거한 제한적인 검색기능을 제공하고 있다. 본 논문에서는 영문 문서영상전체에 대한 검색을 위한 단어 영상 형태 특징기반의 단어검색시스템을 제안한다. 본 논문에서는 검색의 효율성과 정확도를 높이기 위해 1) 기존의 단어검색시스템에서 사용된 특징들을 조합하여 사용하며, 2) 특징의 개수 및 위치뿐만 아니라 특징들의 순서를 포함하여 매칭하는 방법을 사용하며, 3) 특징비교에 의해 검색결과를 얻은 후에 여과목적으로 문자인식을 부분적으로 적용하는 2단계의 검색방법을 사용한다. 제안된 시스템의 동작은 다음과 같다. 문서 영상이 주어지면, 문서 영상 구조가 분석되고 단어 영역들의 조합으로 분할된다. 단어 영상의 특징들이 추출되어 저장된다. 사용자의 텍스트 질의가 주어지면 이에 대응되는 단어 영상이 만들어지며 이로부터 영상특징이 추출된다. 이 참조 특징과 저장된 특징들과 비교하여 유사한 단어를 검색하게 된다. 제안된 시스템은 IBM-PC를 이용한 웹 환경에서 구축되었으며, 영문 문서영상을 이용하여 실험이 수행되었다. 실험결과는 본 논문에서 제안하는 방법들의 유효성을 보여주고 있다. Abstract Most existing digital libraries for document image retrieval provide a limited retrieval service due to their indexing from document titles and/or the content of document abstracts. This paper proposes a word spotting system for full English document image retrieval based on word image shape features. In order to improve not only the efficiency but also the precision of a retrieval system, we develop the system by 1) using a combination of the holistic features which have been used in the existing word spotting systems, 2) performing image matching by comparing the order of features in a word in addition to the number of features and their positions, and 3) adopting 2 stage retrieval strategies by obtaining retrieval results by image feature matching and applying OCR(Optical Charater Recognition) partly to the results for filtering purpose. The proposed system operates as follows: given a document image, its structure is analyzed and is segmented into a set of word regions. Then, word shape features are extracted and stored. Given a user's query with text, features are extracted after its corresponding word image is generated. This reference model is compared with the stored features to find out similar words. The proposed system is implemented with IBM-PC in a web environment and its experiments are performed with English document images. Experimental results show the effectiveness of the proposed methods.