The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

Technical Advances, Image Quality and Quality Control Regulations in Mammography

  • Ng, Kwan-Hoong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.38-41
    • /
    • 2002
  • Mammography is considered the single most important diagnostic tool in the early detection of breast cancer. Today's dedicated mammographic equipment, specially designed x-ray screen/film combinations, coupled with controlled film processing, produces excellent image quality and can detect very low contrast small lesions. In mammography, it is most important to produce consistent high-contrast, high-resolution images at the lowest radiation dose consistent with high image quality. Some of the major technical development milestones that have let to today's high quality in mammographic imaging are reviewed. Both the American College of Radiology Mammography Accreditation Program and the Mammography Quality Standards Act have significant impact on the improvement of the technical quality of mammographic images in the United States and worldwide. A most recent development in digital mammography has opened up avenues for improving diagnosis.

  • PDF

A study of dose and image quality with Convergence FFDM and DBT using tissue-equivalent phantom in digital mammography (유방조직등가 팬텀을 이용한 디지털유방촬영장치의 FFDM과 DBT의 선량과 영상품질에 대한 융합 연구)

  • Yoo, Young-Sin;Han, Dong-Kyoon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, we measure dose against various density and thickness using phantom to compare FFDM to DBT of Digital mammography equipment and evaluate usefulness of DBT through compare the image quality of FFDM and DBT. We use mammography equipment, Selenia Dimensions ; this is able to examine breast by both FFDM and DBT, The results are that when the thickness of phantom is 6cm or more and density is 70% or more and the thickness of phantom is 7cm or more and density is 50% or more, AGD of DBT is lower than that of FFDM. The evaluation results of image quality are that in the tumor and small calcification group that composed by mammary tissue and fat, FFDM is great and in fibrin, DBT is great. But in the all thicknesses of BR3D phantom that reflected overlapped tissue of breasts, DBT is great in calcification group, fibrin and tumor. DBT is greater image quality and lower dose more than FFDM in Thick and high density breast, Therefore, DBT is more useful in Korean women's breast that is characterized dense breast than FFDM.

The Image Quality according to Target-Filter Combination in Digital Mammography (디지털유방촬영장치에서 타깃-필터 조합에 따른 영상분석)

  • Kim, Do-Hyung;Choi, Seokyoon;Kim, Dong-Hyen
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.121-124
    • /
    • 2015
  • Digital Mammography is very important for the early diagnosis of breast cancer. but excessive radiation dose to the patient may increase the probability of occurrence of breast cancer. absorbed dose rate and signal, noise, and contrast in accordance with the change of the filter, and analyzed the signal-to-noise ratio. absorbed dose rate GE Equipment is higher than that of Siemens and Hologic. using the material of Mo / Mo was lower than the other target-filter combination. SNR of Siemens equipment is high and measured high when Mo / Mo selected, the other two devices was measured high when Mo / Rh selected. when you choose a target-filter combination our results will be a good indicator.

Digital Mammography as a Screening Tool in Korea (국가암검진사업에서 디지털 유방촬영술의 현황과 과제)

  • Soo Yeon Song;Seri Hong;Jae Kwan Jun
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.2-11
    • /
    • 2021
  • More than 4 million women undergo breast cancer (BC) screening with mammography each year in Korea. Digital mammography (DM) was introduced in 2000, and it has been reported to have a higher diagnostic accuracy than screen-film mammography (SFM) or computed radiography (CR) in women with dense breasts. According to a study using data from the National Cancer Screening Program for BC, the diagnostic accuracy of DM was higher than those of SFM and CR, regardless of age, breast density, and screening round. Currently, despite high supply rate among OECD countries, the distribution of DM equipment is approximately 35% in Korea. For quick replacement with DM, it will be necessary to improve its fee for the National Health Insurance and support an educational program for radiologists. In addition, efforts should be made to increase the accessibility of DM.

Implementation of Digital Mammogram CAD Algorithm (디지털 유방영상의 CAD 알고리즘 구현)

  • Lee, Byungchea;Choi, Guirack;Jung, Jaeeun;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • Medical imaging has increased rapidly in the increase of interest in health, with the development of computer technology, digitization of medical imaging is rapidly advancing, PACS has been introduced to the medical field. Increase in the production of medical images by these phenomena made increased the workload of radiologist who must read a medical image. in response to the need for secondary diagnosis using a computer, The term of CAD in medical radiology field was introduced. In this study, we have proposed a CAD algorithm for the interpretation of the image obtained by the digital X-ray mammography equipment. The experiments were performed by programmed in Visual C++ for the proposed algorithm. A result of the execution of the CAD algorithm seven sample images, the results of five samples was confirmed in breast cancer and benign tumors, both the images sample was error processing. If you use a program that implements this with the algorithm proposed in this study it is helpful to reading breast images, and it is considered to contribute significantly to the early detection of breast cancer.

Comparative Analysis According to Acquisition Type by Using the Resolution Phantom for Mammography Equipment (유방촬영의 영상획득 방법에 따른 해상력 차트의 비교 분석)

  • Kim, Jae-Hoon;Ji, Yun-Sang;Dong, Kyung-Rae;Kwak, Jong-Gil
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.287-290
    • /
    • 2018
  • Nowadays, diseases related with breast are increasing rapidly and because of this high quality of resolution images is required to get clear detail specially for early detection and diagnosis. It has a tendency to use digital equipments than analog one in clinic. In this experiment, DR, CR, and Film are used for the resolution applied by AEC. Resolution phantom in DR was $7LP{\cdot}mm^{-1}$ in both verticality and horizontality. In CR, however, it was $6LP{\cdot}mm^{-1}$ in both which was lower this standard. The resolution stayed in range of standard in Film but it showed differences between $11{\sim}14LP{\cdot}mm^{-1}$ Overall, the difference of resolution was displayed Film, DR and CR, in order, which means the study is needed for more high quality of digital images.