• Title/Summary/Keyword: digital impression

Search Result 166, Processing Time 0.026 seconds

Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision

  • Kwon, Miran;Cho, Youngmok;Kim, Dong-Wook;Kim, MyungSu;Kim, Yoon-Ji;Chang, Minho
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.95-104
    • /
    • 2021
  • Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 ㎛, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

A Study on Visual Attention Factors for Advertising Photographs (광고 사진을 위한 시각적 주의 기초요인 연구)

  • Kim, Dae-Wook
    • Journal of Digital Convergence
    • /
    • v.17 no.3
    • /
    • pp.413-425
    • /
    • 2019
  • We see many images every day, some of these images are stored in memory, and the majority are immersed in the unconscious world. Visual elements are seen by personal attention or by visual or biological attention factors. Specific and clear discovery of this visual attention has not yet been made. However, there is an interesting discussion of this visual attention in the fields of interior, design, visual perception, advertising, and psychology. Advertising photographers are expected to produce what their work will have on viewers and consumers. However, the adjustment of subject, exposure, color, or post-production, which could have a visual effect on the consumer, was determined only by the photographer's senses rather than the experimental verification. The advertisement photographs provide a specific image related to the object to be advertised and deliver a certain message. Therefore, it is necessary to understand the effect of the image in a certain visual way. According to previous studies, there are two major factors that affect the visual impression of the viewer. One is the factor depending on the type and content of the subject and the other is the factor about the density and color of the subject. The purpose of this study is to investigate the meaningful changes in the visual perception depending on the shape, content, color and tone of the subject, which can be called the main subject, And to analyze the effects of I will study some implications of visual elements through various analyzes.

A noninvasive esthetic treatment of isolated microdontia using new high-translucent cubic-phase zirconia (5Y-PSZ) laminate veneers: A case report (고투명도 입방정상 지르코니아(5Y-PSZ) 라미네이트를 이용한 왜소치의 비침습적 심미 수복 증례)

  • Ahn, Min-Zin;Ahn, Do-Gwan;Pyo, Se-Wook;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.263-270
    • /
    • 2019
  • Current trends in restorative dentistry focus on improving the esthetics and keeping the sound dental tissues as long as possible. The aims of this case report were to describe the successful outcome of cubic-phase zirconia laminate veneers for a patient with isolated microdontia by using a digital workflow, and to describe their clinical implications. A 15-year-old female who had isolated microdontia in combination with spacing visited Ajou University Dental Hospital for esthetic treatment. In this case, 6 maxillary anterior teeth were restored with cubic-phase zirconia laminate veneers without tooth structure removal by using a digital impression, computer-aided design (CAD) software, and computer-aided manufacturing (CAM) procedures. At 6-month follow-up, no distinct mechanical and biological complications were detected and the prostheses exhibited satisfactory esthetics and functions. Due to its favorable tissue responses and enhanced translucency, cubic-phase zirconia can be a suitable strategy for a noninvasive esthetic approach.

Development of Hair Accessory Designs Using Royal Hair Ornaments (왕실 머리장식을 응용한 헤어 액세서리 디자인 개발)

  • Jinyoung Ryu;Jiyeon Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.83-90
    • /
    • 2023
  • The recent trend in younger generations of wearing traditional costumes or incorporating fusion hanbok into daily wear necessitates the development of modern hair accessories to complement hanbok. The purpose of this study is to develop practical and modern hair accessory designs inspired by royal women's hair ornaments that complement hanbok, and therefore expand the scope of fashion content development utilizing hanbok culture as well as meeting the demand for various experiences of traditional culture. This research studied the literature on traditional hairstyles and accessories of Queen Yeong and constructed models of these accessories for the purpose of empirical research. The production process first required creating a basic foundation of nylon mesh reflecting the silhouette of a traditional hairstyle, and then grafting a digital textile printed fabric using majestic and extravagant royal relics on top, thus employing the trompe l'oeil technique to ultimately give the impression of wearing traditional jewelry. As a result, a total of six hair accessory designs were completed, produced with hairbands, hair pins, and hair ties. In addition, the accessories are designed to be easily worn regardless of the wearer's hair style, and the stiff yet flexible nylon mesh effectively expresses the shape of a voluminous hairstyle and creates an optical illusion, blending into the hair. These research results present a unique aesthetic and cultural experience to the greater public seeking both daily entertainment and value from rarity.

DENTAL CROWDING AND ITS RELATIONSHIP TO TOOTH SIZE AND ARCH DIMENSION IN KOREAN (한국인에서 치아 및 악궁의 크기와 총생의 관계)

  • Lee, Nan-Young;Hong, Sung-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.510-521
    • /
    • 2006
  • This investigation was undertaken to examine the extent to which tooth size and arch dimension each contribute to dental crowding. The sample included 50 subjects with well aligned dentition (25 males, 25 females) and those of 40 subjects with gross dental crowding(20 males, 20 females). Plaster model and digital model made from alginate impression taken at the one visit. Tooth size, arch length, arch perimeter, intercanine width and intermolar width was measured on the plaster and digital models. The findings in this study lead to the following conclusions. 1. In maxilla, the mesiodistal diameters of lateral incisor and premolars of the crowded group were significantly larger than those of the normal occlusion group (P<0.05). 2. In mandible, the mesiodistal diameters of central incisor, canine and premolars of crowded group were significantly larger than those of the normal occlusion group (P<0.05). 3. In maxilla, arch perimeter and intermolar width of crowded group were significantly smaller than normal occlusion group but intercanine width of crowded group were larger than normal occlusion group (P<0.05). There was no significantly difference in arch length (P>0.05). 4. In mandible, arch perimeter of crowded group was smaller than normal occlusion group(P<0.05). There were no difference in arch length intermolar width and intercanine width (P>0.05) 5. In the analysis of correlation coefficients of arch length discrepancy with variables, arch perimeter, intermolar width and mesiodistal width of 2nd premolar showed positive correlations in maxilla. 6. There was a significant difference between tooth width measurements made by the 2 methods, with all the digital model measurement larger than plaster model measurements (P<0.05) : the magnitude of the differences does not appear to be clinically relevant. 7. In the analysis for reproducibility, the plaster model measurement was showed lower degree of correlation between 1st and 2nd measurement than digital model.

  • PDF

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.