• Title/Summary/Keyword: digital image

Search Result 5,996, Processing Time 0.038 seconds

Control for Optical Image Stabilization System in Digital Cameras (디지털 카메라용 이미지 안정화 시스템 제어)

  • Cho, Ju-Yeon;Cho, Woo-Jong;Park, Jung-Ho;Kim, Kyung-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.411-414
    • /
    • 2010
  • As high quality image is required for digital cameras in recent use, the image stabilization technique has drawn much attention to prevent image degradation from shaky disturbance by users. In this paper, the optical image stabilization (OIS) system for DSLR (Digital Single Lens Reflex) camera is considered. First, the analytic model of an OIS system is presented to demonstrate the mechanism of image destabilization due to unknown disturbance that causes blurry images on CCD sensor. Then, to enhance the stabilization performance, a sliding mode control based on the min-max nonlinear control is introduced. Through the experiments and simulations, the effectiveness of the proposed method will be verified.

Acquisition and application of digital medical image in radiology (디지털 방사선 의료영상획득과 적용)

  • ;Nam, Sang Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1528-1535
    • /
    • 1997
  • Many radiological modalities has been applied to medicine as a basic fundamental diagnosis and therapy recently. The prevalence of computer systems affect most images to be digitized. However conventional X-ray film images are not digital images eventhough they covers 70% of all radiologica images. This is the hinderacne of building PACS. In this paper all radiological digital imaging parts such as DSA. CR. MRI. SPECT. PET and ultrasonography were briefly introduced and the applications were described. In brief digital radiography contribute to enhance the medical service quality. And the digital substituition of conventional X-ray film image is inevitable.

  • PDF

Stereo Image Insertion using Alteration of DCT Coefficients of Color Channels (칼라채널의 DCT 계수 변경을 이용한 스테레오 영상 삽입)

  • 이호근;천성렬;하영호
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.175-178
    • /
    • 2003
  • This paper proposes a stereo image insertion technique on DCT coefficients using the embedded method developed in the digital watermarking in due consideration of compatibility with conventional 2D system such JPEG, and MPEG. In conventional transmission method users with conventional digital TV cannot watch the transmitted 3D image sequence as 2D image, because of affectivity of conventional 3D image compression. To give an answer, in this paper, DCT coefficients are changed according to its disparity on YCbCr channels. Our method can insert stereo images into a conventional image compression method based on DCT.

  • PDF

New Image Mapping Algorithm for 3D Integral Imaging Display System used in Virtual Reality

  • Suk, Myung-Hoon;Min, Sung-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.41-45
    • /
    • 2005
  • A new algorithm of the image mapping which is a technique of the elemental image generation is proposed. The proposed method is based on the characteristics of the lens array such as the number, the size and the focal length of the elemental lens. The 3D image generated by 3D graphic API such as OpenGL can be directly adopted without the complex adaptation. Since the image mapping using the proposed method can enhance the speed of the elemental image generation, the computer- generated integral imaging system can be applied to virtual reality system.

  • PDF

A Research of User Experience on Multi-Modal Interactive Digital Art

  • Qianqian Jiang;Jeanhun Chung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2024
  • The concept of single-modal digital art originated in the 20th century and has evolved through three key stages. Over time, digital art has transformed into multi-modal interaction, representing a new era in art forms. Based on multi-modal theory, this paper aims to explore the characteristics of interactive digital art in innovative art forms and its impact on user experience. Through an analysis of practical application of multi-modal interactive digital art, this study summarises the impact of creative models of digital art on the physical and mental aspects of user experience. In creating audio-visual-based art, multi-modal digital art should seamlessly incorporate sensory elements and leverage computer image processing technology. Focusing on user perception, emotional expression, and cultural communication, it strives to establish an immersive environment with user experience at its core. Future research, particularly with emerging technologies like Artificial Intelligence(AR) and Virtual Reality(VR), should not merely prioritize technology but aim for meaningful interaction. Through multi-modal interaction, digital art is poised to continually innovate, offering new possibilities and expanding the realm of interactive digital art.

Updating Building Layer of Digital Map Using Airborne Digital Camera Image (디지털항공영상을 이용한 수치지도의 건물레이어 갱신)

  • Hwang, Won-Soon;Kim, Kam-Rae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.31-39
    • /
    • 2007
  • As the availability of images from airborne digital camera with high resolution is expanded, a lot of concern are shown about the production of orthoimage and digital map. This study presents the method of updating digital map using orthoimage from airborne digital camera image. Images were georectified using GPS surveying data. For the generation of orthoimage, Lidar DEM was used. The absolute positional accuracy of orthoimage was evaluated using GPS surveying data. And that of the building layer of digital map was estimated using the existed digital map at the scale of 1:1,000. The absolute positional accuracy of orthoimage was as followed: RMSE in X and Y were ${\pm}0.076m$ and ${\pm}0.294m$. The RMSE of the building layer were ${\pm}0.250m$ and ${\pm}0.210m$ in X and Y directions, respectively. The RMSE of the digital map using orthoimage from Aerial Digital Camera image fell within allowable error range established by NGII. Consequently, updating digital map using orthoimage from Aerial Digital Camera image can be applied to various fields including the construction of the framework data and the GIS of local government.

  • PDF

Prediction of Bone Aging by Adapting Image J (Image J를 활용한 뼈의 노화도 예측법)

  • Jung, Hong Moon;Won, Do Yeon;Jung, Jae Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • Calcium density in human bones decreases as people are getting older due to the interior or exterior environmental factors. Bone aging forms osteoporosis. And this can bring out various spine fractures which develops a complications. Thus the prediction of seniliy is one of the important factors in spine diseases. Once spine aged, diverse fractures occur such as compression fracture and micro fracture. Side images of the spine by the digital radiography (DR) were prepared, and pixel arbitrary unit with Image J was measured from one spot in the lumbar bone part. By calculating pixel arbitrary unit of the simple contrast, it was obtained that the value of pixel arbitrary unit decreased as seniliy of bones increased. By simply applying Image J to the seniliy of patient's spine, the seniliy of bones predicts the level of danger with only digital radiography(2D) image. consequently we show that Image J value of pixel arbitrary unit index for predicts the level of precaution of osteoporosis patient.

  • PDF

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Implementation of a Single Human Detection Algorithm for Video Digital Door Lock (영상디지털도어록용 단일 사람 검출 알고리즘 구현)

  • Shin, Seung-Hwan;Lee, Sang-Rak;Choi, Han-Go
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.127-134
    • /
    • 2012
  • Video digital door lock(VDDL) system detects people who access to the door and acquires the human image. Design considerations is that current consumption must be minimized by applying fast human detection algorithm because of battery-based operation. Since the digital door lock takes an image through a fixed camera, detection of a person based on background image leads to high degree of reliability. This paper deals with a single human detection algorithm suitable for VDDL with fulfilling these requirements such that it detects a moving object in an image, then identifies whether the object is a person or not using image processing. The proposed image processing algorithm consists of two steps: Firstly, it detects the human image region using both background image and skin color information. Secondly, it identifies the person using polar histogram based on proportional information of human body. Proposed algorithm is implemented in VDDL and is verified the performance through experiments.

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF