Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.

Investigation of Learner Recognition to Introduction of Mobile Learning: A Study Targeting Officers at the Ministry of Health and Welfare in Korea

  • Jin, Sunmi;Hyun, Seunghye
    • International Journal of Contents
    • /
    • v.10 no.3
    • /
    • pp.26-34
    • /
    • 2014
  • Mobile learning is a practical learning method for busy adult learners because the mobility of digital devices can overcome the drawbacks of e-learning. However, research is strongly lacking in the theoretical exploration of mobile learning effects and functions and its empirical research. Moreover, the research of learning characteristics and learners' requirements must be considered before applying and disseminating mobile learning into the educational field. To address this shortcoming, this study conducted an online survey with 1,542 officers of the Ministry of Health and Welfare Affairs (MHWA) regarding learner recognition to mobile learning. The analysis of learners' attitudes toward mobile learning, based on age and position, indicated that subordinate workers appeared to place more value on mobile learning. Many participants preferred mobile learning because of its mobility and the effectiveness of anywhere and anytime. However, some participants continue to misunderstand mobile learning and its necessity. Therefore, consideration of learning effectiveness, the form of the content, and learner-centered learning must be reviewed in advance. This study could lead to practical implications of mobile learning.

Ai-Based Cataract Detection Platform Develop (인공지능 기반의 백내장 검출 플랫폼 개발)

  • Park, Doyoung;Kim, Baek-Ki
    • Journal of Platform Technology
    • /
    • v.10 no.1
    • /
    • pp.20-28
    • /
    • 2022
  • Artificial intelligence-based health data verification has become an essential element not only to help clinical research, but also to develop new treatments. Since the US Food and Drug Administration (FDA) approved the marketing of medical devices that detect mild abnormal diabetic retinopathy in adult diabetic patients using artificial intelligence in the field of medical diagnosis, tests using artificial intelligence have been increasing. In this study, an artificial intelligence model based on image classification was created using a Teachable Machine supported by Google, and a predictive model was completed through learning. This not only facilitates the early detection of cataracts among eye diseases occurring among patients with chronic diseases, but also serves as basic research for developing a digital personal health healthcare app for eye disease prevention as a healthcare program for eye health.

Building a Big Data Platform Using Real-time Wearable Devices and Cases of Safety Accidents in KOREA

  • LEE, Ki Seok;CHOI, Youngjin;LEE, Kyung-cheun;SHIN, Yoonseok;YOO, Wi Sung
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.375-381
    • /
    • 2022
  • Safety accidents are of concern during construction projects, even given the recent innovations in digital technologies. These projects remain focused on overcoming specific and limited applications on construction sites. For this reason, the development of an inclusive safety management system has become crucial. This study aims to build a Big Data platform to inform decisions on how to proactively eliminate worker hazards on construction sites. The platform consists of about 100,000 real records and a real-time monitored database featuring various safety indices, such as workers' altitudes, heart rates, and fatigability during construction, which are determined through various wearable devices. The data types are customized and integrated by a research team in accordance with the characteristics of a specific project using hypertext transfer protocol (HTTP). The results can be helpful as efficient tools to ensure successful safety management in complex construction situations. This study is expected to provide three significant contributions to the field, including real-time fatigability analysis and tracking of workers on-site; providing early GPS-based warnings to workers who might be accessing dangerous spaces or places; and monitoring the workers' health indices, based on details from 100,000 cases.

  • PDF

A Study on the Factors Influencing Health Information Literacy of Adolescent (청소년의 건강정보 이해능력에 미치는 영향요인에 관한 연구)

  • Ko, Haesook;Kim, Seonghee
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.31 no.1
    • /
    • pp.357-377
    • /
    • 2020
  • The purpose of this study was to investigate factors affecting the adolescent's health literacy. First, we examined whether information literacy affects adolescents' understanding of health information, and then analyzed how demographic statistics and various other characteristics of adolescents affect health literacy. Data was collected through a survey of 277 middle and high school students. The results of analysis of Multi-regression showed that information literacy was found to have a positive impact on adolescent's health literacy. In addition, factors such as gender, grade level, academic performance, health concern, and frequency of use of digital devices were statistically significant in their affect on adolescent's health literacy. The results of this study can be used as basic data to improve adolescent' comprehension of health information.

A Development of the Prototypes of Smart Sportswear for Trekking and Jogging (트레킹 및 조깅을 위한 스마트 스포츠웨어의 프로토타입 개발)

  • Kim Young-Jun;Kim Hoo-Sung;Seo Jung-Hoon;Lee Sun-Young;Lee Joo-Hyeon;Hwang Eun-Soo;Cho Hyun-Seung
    • Science of Emotion and Sensibility
    • /
    • v.8 no.3
    • /
    • pp.213-220
    • /
    • 2005
  • The purpose of this study is to develop a modular model of smart clothing which can integrate various digital devices in clothing, maintaining the inherent attribute of clothing. For achieving this purpose, several technological devices for the smart clothing for listening to music, bio-monitoring, and environment monitoring were developed, through multidisciplinary cooperation. As the result, total four design prototypes of smart sportswear(trekking wear, jogging wear) for the application of entertainment and health care were suggested.

  • PDF

A Study of Dementia Patient Care Monitoring System Based on Indoor Location Using Bluetooth Beacon (블루투스 비콘을 활용한 실내위치기반 치매환자 모니터링 시스템에 관한 연구)

  • Kwon, Dae-Won
    • Journal of Digital Convergence
    • /
    • v.14 no.2
    • /
    • pp.217-225
    • /
    • 2016
  • In this study, a dementia patient care monitoring system is suggested that uses a wearable type bluetooth beacon to prevent them from going missing. This system shows whether the patients stay within the manageable area and sends a warning message to their monitoring managers' or guardians' smart devices when they leave it. The feature of the system is that it provides the service based on indoor location that makes the beacon worn by dementia patients continuously transmit their location information to the managing server through the smart terminal installed indoors or in hospitals and that enables the monitoring managers or the guardians to receive messages sent from the server that tell the patients' whereabouts through their smart devices. The system suggested in this paper is believed to be a system that effectively contributes to the prevention of the dementia patients' going astray from the hospitals and facilities where they are taking care.

Evaluation of Linearity Air Kerma Applied to the IEC 60601-2-45 Standard in Mammographic X-ray (유방촬영용 X선 진단장치에서 IEC 60601-2-45 표준규격을 적용한 직선성 평가)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Han, Beom-Hee;Han, Sang-Hyun;Lee, Sang-Ho;Mo, Eun-Hee;Kim, Ki-Jung;Lee, Mi-Hwa;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • The quality control items of mammography devices in South Korea do not include the linearity, which is required by international standards. The linearity is a requirement for the adjustment of radiation dose and radiation quality. This study tested the linearity, which was suitable for the IEC 60601-2-45 standard, of the 5 mammography devices. All showed adequate results. Consistent measurement management is required for more developed quality control in the future.

Mechanical properties by resin injection method of orthdontic acrylic resin (교정용 레진장치의 레진주입방법에 따른 기계적 특성)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.341-346
    • /
    • 2020
  • Polymethyl methacrylate (PMMA), a self-curing resin mainly used in removable orthodontic appliances, is an acrylic resin mainly used in the field of modern dentistry. As an advantage, it has been used for a long time as a material for orthodontic devices in dentistry due to its color and volume, tissue affinity, and stability. The production of PMMA can be divided into self-polymerization method and thermal polymerization method according to activation method. Self-curing resins have long been used as orthodontic devices. The resin injection method is largely divided into a sprinkle-on method and a mixing method. In this study, we intend to test the mechanical properties according to the resin injection method of the orthodontic device, such as strength, modulus of elasticity, and surface roughness. There was no significant difference in strength as a result of three-point bending strength test on rectangular specimens (1.4 × 3.0 × 19.0 mm) of orthodontic PMMA. There was also no significant difference in hardness. There was no significant difference in surface roughness. It was confirmed that the orthodontic PMMA had no significant difference in mechanical properties according to the resin injection method of the orthodontic device.

Characteristics of Resin on Antimicrobial Properties of Calibration Devices. (교정장치의 항균에 따른 레진상의 특성)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.309-314
    • /
    • 2020
  • Polymethyl methacrylate (PMMA) is concerned with promoting oral infection due to its low antibacterial activity. To overcome this, the nanoparticles of Ag-MSN, nGO, and CNP were mixed with MMA liquid in a weight ratio of 0, 0.25, 0.5, 1.0, 2.0% compared to resin powder using Orthocryl from Dentarum, a calibration resin, and then instructed by the manufacturer. Accordingly, a specimen for calibration was prepared by mixing PMMA: MMA (1.2: 1) ratio, and physical properties of the calibration resin, antifungal experiments, and statistical analysis were performed. As a result of antibacterial experiments, the antibacterial properties of Ag-MSN increased. In nGO, the antibacterial adhesive effect increased hydrophilicity, not a change in surface roughness. The higher the CNP concentration, the higher the antibacterial activity. This suggests its potential usefulness as an antibacterial dental material for orthodontic devices and temporary restorations.