$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

위장내 음식물에 따른 방사선 감약 및 화질에 관한 연구 (The Study on the Attenuation of X-ray and Imaging Quality by Contents in Stomach)

  • 동경래;지연상;김창복;최성관;문상인;디터케빈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.53-60
    • /
    • 2009
  • 인체의 $40{\sim}50%$인 연부조직에 X선을 조사하면 연부조직의 두께에 따라 투과선량이 감소하며 영상에도 질적 저하를 가져온다. 본 연구는 복부 촬영시 위장내 내용물에 따라 X선 감약 및 화질에 차이가 나타날 수 있다는 가정 하에 실제 위의 조직과 비슷한 조직등가물질 phantom을 제작하여 실제 위장내 내용물에 따른 X선의 감약 변화와 DR (Digital Ridiography)의 ROI수치를 비교해보았다. 단백질 두께가 증가할수록 X-선 감약에 의한 투과선량이 감소되었으며(p < 0.001), Film과 DR 영상에서의 ROI Mean값의 변화도 감소하였다(p <0.001). Film과 DR 영상에서의 ROI Mean값에 대한 비교는 Film이 DR 영상에 비해 단백질 두께에 따른 농도의 변화 값이 크게 나타났다(p < 0.001). 이와 같은 결과를 종합해 볼 때 DR system 촬영 보다는 필름을 사용하는 단순촬영에서 금식(NPO ; nothing by mouth)의 필요성이 더 중요함을 알 수 있다.

  • PDF

디지털 방사선 촬영술을 이용한 치근 흡수 판독에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE TOOTH ROOT RESORPTION FOR DIGITAL RADIOGRAPHY)

  • 오필교;김재덕
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.375-387
    • /
    • 1995
  • The purpose of this study was to quantitatively evaluated experimental tooth root resorption for digital radiography. For this study, experimentally three root sites were used, and radiograms were taken with standardized apparatus. Digital imaging system were consisted of NEC PC-980l(computer), TRINITRON(monitor), SONY XC-711 CCD camera. The display monitor had a resolution of 512X512 pixels. The obtained results were as follows: 1. In the difference of the four X-ray film of the contrast correction, the contrast difference was one gray scale variation at mean value. 2. Viewing of the view box of the periapical radiographs, experimental tooth root resorption of the periapical area of the first premolar, middle of mesial surface of the first molar mesial root, middle of lingual surface of the first molar distal root were recognized by increased diameter. 3. On the analysis by histogram, the periapical area of the first premolar, the middle of mesial surface of the first molar mesial root were each recognized tooth root resorption of the 5,6,7 pixel, 2,4,5 pixel by increased diameter. 4. On the analysis by histogram, the middle of lingual surface of the first molar distal root was each recognized tooth root resorption of the none, 3,6 pixel by increased diameter.

  • PDF

Skin entrance dose for digital and film radiography in Korean dental schools

  • Cho Eun-Sang;Choi Kun-Ho;Kim Min-Gyu;Lim Hoi-Jeong;Yoon Suk-Ja;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.203-205
    • /
    • 2005
  • Purpose: This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Materials and Methods: Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician (s) at each school to set the exposure parameters and aiming the x-ray tube for the periapical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter : Unfors instruments, Billdal, Sweden). Results: The median dose was $491.2{\mu}Gy$ for digital radiography and $1,205.0{\mu}Gy$ for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Conclusion: Fifty-nine percent skin entrance dose reduction with digital periapical radiography was achieved over the film radiography in Korean dental schools.

  • PDF

인접면 치근 인공우식병소의 깊이 평가: 구내 일반 방사선사진과 디지털 방사선사진과의 비교 (The radiographic depth of approximal root cavities : A comparative study of conventional and digital radiographs)

  • 박현정;조봉혜
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.15-20
    • /
    • 2003
  • Purpose : To investigate the reproducibility of the conventional and digital radiographs to determine the depth of approximal root cavities. Materials and Methods : A total of 80 artificial root cavities were prepared in the approximal surfaces of premolars, maxillary and mandibular molars. Standardized radiographs were taken at the baseline (0° horizontal and 0° vertical) and at a horizontal angulation of 10° in both mesial and distal directions. Radiographic cavity depths were measured by both conventional and digital radiographs. Results: At 0° horizontal angulation, no statistically significant differences could be determined between the results of conventionally and digitally determined radiographic depths with respect to the actual cavity depths in all premolar, maxillary, and mandibular molar groups. All conventional and digital radiographic depths at both 10° mesial and distal angulations showed statistically significant increases in depth compared to the actual cavity depths (p < 0.05), with the exception of digital radiographic depth at 10° mesial angulation for premolars. There were no statistically significant differences between conventional and digital radiographic depths for all groups. Conclusion: The present study suggests that both conventional and digital radiographs provide reproducible assessment of the depth of the approximal root cavity. But horizontal X-ray beam movements are likely to result in increase in radiographic cavity depth.

  • PDF

흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안 (Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography)

  • 심지나;이영진
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.139-145
    • /
    • 2021
  • 본 연구는 흉부 X-ray 검사 시 디지털 영상의 적절한 유효 Detector exposure index (DEI) 범위 내의 영상의 Dose area product (DAP)값과 유효선량을 비교함으로써 적절한 관전압의 범위를 확인하고자 하였다. GE Definium 8000을 사용하여 흉부팬텀을 이용한 Chest PA 검사를 재현하였다. kVp range는 60~130 kVp, mAs range는 2.5 ~ 40 mAs로 설정하였다. 획득한 영상을 유효한 DEI 범위의 영상으로 분류하고 측정한 DAP을 이용하여 PC-Based Monte Carlo Program을 통해 유효선량을 계산하였다. 영상의 정량적 평가를 하기 위해 Picture archiving and communication system을 이용하여 흉추, 갈비뼈가 포함된 폐야부위, 갈비뼈가 포함되지 않은 폐야부위, 간 등 총 네 부분의 Signal to noise ratio (SNR)를 측정하였다. 관전압 별 그룹의 유의성은 Kruskal-wallis test와 사후검정으로 Mann-whitney test를 시행하여 검증하였으며 검증에 사용된 신뢰구간은 95%이다. 총 13개의 관전압 중 적정한 유효 DEI 범위안에 포함된 네개의 관전압 (60~90 kVp)을 각각 비교하였을 때, DAP는 60 kVp를 기준으로 80 kVp, 90 kVp를 비교한 결과에서만 유의한 차이를 보였다 (p= 0.034, 0.021). 유효선량은 모든 관전압 그룹에서 유의한 차이를 보이지 않았다 (p>0.05). SNR은 간 부위에서 80 kVp와 90 kVp를 제외한 모든 그룹에서 유의한 차이를 보였다 (p<0.05). 그러므로 디지털 환경에서 적정한 흉부 X-ray 영상의 농도를 나타내기 위해 100 kVp 이상의 고관전압은 환자 선량 및 영상 측면에서 재고할 필요성이 있다고 사료된다.

선형시스템 전달이론을 이용한 간접변환방식 디지털 래디오그라피 디텍터의 신호 및 잡음 분석 (Signal and Noise Analysis of Indirect-Conversion Digital Radiography Detectors Using Linear-systems Transfer Theory)

  • 윤승만;임창휘;한종철;조옥라;김정민;김호경
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.261-273
    • /
    • 2010
  • 간접변환방식 CMOS (complementary metal-oxide-semiconductor) 엑스레이 디텍터 시스템의 성능 분석 및 개선을 위하여 공간주파수에 따른 DQE (detective quantum efficiency)를 모델링 하였다. 모델의 검증을 위하여 마모그라피 W/Al 선질에 대한 modulation-transfer function (MTF), noise-power spectrum (NPS)를 측정하고 이로부터 DQE를 계산하였으며, 모델과 측정된 DQE는 전체 공간주파수 영역에서 서로 잘 일치함을 확인하였다. 검증된 모델을 이용하여 형광스크린 양자효율 및 MTF, Swank 잡음, 포토다이오드 양자효율 등 CMOS 디텍터 시스템의 DQE 성능에 영향을 미칠 수 있는 다양한 디자인 파라미터의 역할을 살펴보았다. 엑스레이 디텍터 시스템의 신호 및 잡음 분석에 대해 이와 같은 선형시스템 전달을 이용한 이론적인 접근법은 이미 개발된 의료영상시스템을 이해할 수 있는 유용한 도구일 뿐만 아니라 새로운 디텍터 개발 및 최적화를 위한 도구로 활용될 수 있을 것이다.

디지털방사선영상에서 산란선의 영상특성 평가 (Evaluation of Image Quality for Scattered X-rays using in Digital Radiography)

  • 김한솔;김창수
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.395-403
    • /
    • 2022
  • 본 연구에서는 디지털방사선영상 시스템에 사용되는 평판형 검출기(flat-panel detector, FPD)를 이용하여 조직 등가 물질인 폴리메틸메타아크릴레이트(Polymethyl Methacrylate, PMMA)의 두께 변화에 따라 발생되는 산란선이 영상품질의 영향으로서 해상력 평가의 변조전달함수(modulation-transfer function, MTF)와 잡음력 스펙트럼(noise-power spectrum, NPS)으로 정량적인 영상 평가를 위한 연구를 수행하였다. 해상력-차트 팬텀 영상으로 PMMA 두께가 증가할수록 산란선의 영향이 커져 변조특성이 저하 되는 것을 알 수 있고 영상이 밝다. 결과는 영상의 잡음이 많아진다는 것을 알 수 있는데 공간주파수 별로 확인하기 위해 푸리에 변환으로 잡음력 스펙트럼 영상을 얻었다. 그러므로 영상에서 피사체로서 PMMA 두께 증가에 따라 산란선의 변화를 MTF로 평가하여 해상도 특성변화와 2차원 잡음력 스펙트럼을 1차원 값으로 나타낸 결과를 통해 PMMA 두께와 잡음은 비례하는 것을 확인할 수 있다.

CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가 (Imaging Characteristics of Computed Radiography Systems)

  • 정지영;박혜숙;조효민;이창래;남소라;이영진;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.63-72
    • /
    • 2008
  • 최근 의료영상저장 및 전송 시스템(Picture Archiving and Communication System, PACS)의 발전과 함께 디지털 영상의 발전이 가속화되면서, 특히 기존의 아날로그 시스템을 활용할 수 있는 컴퓨터 X-선 촬영(Computed Radiography, CR)의 활용도가 높아졌다. 본 연구에서는 실제 임상에서 사용되고 있는 Agfa CR system (Agfa CR 2.5; Agfa, Belgium)과 Fuji CR system (FCR 9000C; Full, Japan)을 이용하여 영상의 정량적 평가에 널리 사용되고 있는 변조전달함수(Modulation Transfer Function, MTF), 잡음력 스펙트럼(Noise Power Spectrum, NPS), 양자검출효율(Detective Quantum Efficiency, DQE)를 통해 시스템간의 성능 비교 및 I.P (Imaging Plate) 크기별 픽셀 크기 차이 및 선량의 변화에 의한 화질영향을 정량적으로 평가하였다. X-선 영상 획득실험을 위하여 국제표준인 IEC 61267에서 제공하는 RQA5의 선질(Additional Filter $0.7+21Al[mm],\;71[kV_p])$을 사용하였다. 실험 결과 Agfa CR 시스템의 경우 10% 응답의 MTF는 $8{\times}10$ inch와 $14{\times}17$ inch I.P에서 각각 3.9, 2.8 cycles/mm으로 측정되었으며, Fuji CR 시스템의 경우 각각 3.4, 3.2 cycles/mm로 측정되었다 선량의 변화에 따른 MTF도 측정결과는, 두 시스템 모두 선량변화에 따른 MTF의 차이는 크지 않았으며, MTF 10% 응답 주파수 영역도 거의 같은 것을 확인하였다. 이러한 결과를 통하여 선량은 영상의 해상력 및 MTF에는 큰 영향을 미치지 않는 것을 확인하였다. NPS의 경우 Agfa CR 시스템의 $100{\mu}m$ 픽셀 크기를 갖는 $8{\times}10$ inch I.P와 $150{\mu}m$ 픽셀 크기를 갖는 $14{\times}17$ inch I.P사이에 큰 차이가 없었다. 또한 두 시스템 모두 선량이 증가할수록 NPS가 좋아지는 결과를 나타내었다. 진단가능영역인 1.5 cycles/mm 주파수 영역에서 DQE의 효율 측정결과 Agfa CR 시스템의 $8{\times}10$ inch I.P가 11%로 측정되었으며, $14{\times}17\;inch\;I.P$는 8.8%로 측정되었다. Agfa CR 시스템의 DQE 효율 차이는 고주파수 영역에서 두드러지게 나타났다. Fuji CR 시스템의 경우 I.P 크기별 픽셀 크기는 $100{\mu}m$로 동일하였기 때문에 DQE 효율 측정결과 큰 차이를 보이지 않았다. 또한 두 시스템 모두 선량이 증가할수록 DQE 효율은 감소함을 나타내었다. 화질평가의 복합적인 요소를 담고 있는 DQE 측정은 장치의 성능을 점검하고, 환자의 피폭선량을 개선시키는데 중요한 역할을 한다. 본 연구에서는 Agfa CR 시스템과 Fuji CR 시스템의 픽셀 크기별, 선량별 DQE를 측정함으로써 CR 시스템의 임상적 응용의 최적화를 위한 기초 자료로서 이용될 것으로 판단된다.

  • PDF

X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구 (A study on electrical response property of photoconductor film for x-ray imaging sensor)

  • 강상식;김찬욱;이미현;이광옥;문용수;안성아;노시철;박지군
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.29-33
    • /
    • 2009
  • 최근 디지털 방사선 영상획득을 위한 평판형 X선 검출기에 이용되는 광도전체(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ 등)에 대한 관심이 증대되고 있다. 본 연구에서는 $HgI_2$ 와 a-Se 필름 변환체에 대해 X선에 대한 전기적 신호검출 특성을 조사하였다. 수백 마이크로의 두꺼운 광도전체 필름 제작을 위해 $HgI_2$는 입자침전방법을 이용하였고, a-Se은 종래의 진공열증착법을 이용하였다. 제작된 시편에 대한 전기적 특성 실험은 누설전류, 신호응답 특성, 민감도 등을 측정하였다. 실험결과로부터, $HgI_2$는 상용화된 a-Se에 비해 낮은 동작전압특성과 우수한 신호 발생율을 보임을 알 수 있었다.

  • PDF