Intelligent Automatic Sorting System For Dried Oak Mushrooms

  • Lee, C.H.;Hwang, H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.607-614
    • /
    • 1996
  • A computer vision based automatic intelligent sorting system for dried oak mushrooms has been developed. The developed system was composed of automatic devices for mushroom feeding and handling, two sets of computer vision system for grading , and computer with digital I/O board for PLC interface, and pneumatic actuators for the system control. Considering the efficiency of grading process and the real time on-line system implementation, grading was done sequentially at two consecutive independent stages using the captured image of either side. At the first stage, four grades of high quality categories were determined from the cap surface images and at the second stage 8 grades of medium and low quality categories were determined from the gill side images. The previously developed neuro-net based mushroom grading algorithm which allowed real time on-line processing was implemented and tested. Developed system revealed successful performance of sorting capability of approximate y 5, 000 mushrooms/hr per each line i.e. average 0.75 sec/mushroom with the grading accuracy of more than 88%.

  • PDF

A Microcomputer-Based Data Acquisition/Control System for Engine Performance Test(I) -Automation of Engine Performance Test and Data Acquisition- (마이크로컴퓨터를 이용한 엔진성능시험(性能試驗)의 자동화(自動化)에 관한 연구(硏究)(I) -엔진성능시험(性能試驗)과 데이터수집(蒐集)의 자동화(自動化)-)

  • Ryu, K.H.;Chung, C.J.;Park, B.S.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.3
    • /
    • pp.7-16
    • /
    • 1987
  • This study was carried out to develop a microcomputer-based data acquisition and control system which was able to collect the data of engine performance test automatically and control the speed and load of the engine. The results of the study are summarized as follows: 1. The signal processing devices, which were able to measure cylinder pressure, coolant temperature, compositions of exhaust gas, fuel consumption, engine rpm and torque etc., were developed. The results of calibration showed that all of devices had high accuracy ranging from 0.3% to 0.69% respectively. 2. The PIA (peripheral interface adapter) for interfacing digital signal and PTM (programmable timer module) for displaying real time every 0.0408 sec were designed and developed. 3. An engine-speed control system using a stepping motor and driver was developed. The control system had the stability, and faster settling time than the manual control system. 4. The automatic control system of electrical dynamometer, which was able to control the speed and load of dynamometer, was developed with a SSD (shackleton system driver) and D/A converter. 5. The computer programs, which were able to collect and process the data of engine tests, were developed using both the machine language and BASIC.

  • PDF

Body Composition Analysis Study of Postpartum Women With Cold-Hypersensitivity (수부냉증이 있는 산모의 체성분학적 특성 분석)

  • Lee, Mi-Joo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Purpose :To analyze body composition in postpartum women with cold-hypersensitivity, their edema index, skelectal muscle's weight and body fat were measured and analyzed with cold hypersensitive postpartum women compared with those of non-cold hypersensitivity. Methods : We studied 38 postpartum women visiting Gangnam Kyung-Hee Korean Hospital from 1 st October 2010 to 30th september 2011. they were subjected to Digital Infrared Thermal Imaging and those with thermal difference greater than $0.3^{\circ}C$ between anterior forearm and center of hand were diagnosed with cold hypersensitivity. Cold hypersensitivity group were consisted of 11 women, the other were consisted of 26 women. All of them were measured Edema index, skelectal muscle's weight and body fat by Inbody720(body composition scanner). We studied the difference of Body composition factor between two groups and relationship between cold-hypersensitivity, Edema index, skelectal muscle's weight and body fat by Independent Samples T-test and Spearman Correlation. Results : No significant differences were observed in edema index, skelectal muscle's weight and body fat between two groups. Conclusion : There was no significant relationship among the Cold-hypersensitivity and Body composition factor(Edema index, skelectal muscle's weight. body fat). But furthemore large scale study is required.

  • PDF

Photophysical Parameters, Photodecomposition, Fluorescence Quenching and Convolutive Voltammetry of 7-Diethylaminocoumarin (DEAC) Laser Dye (7 Diethylaminocoumarin (DEAC) 레이져 염료의 광물리적 파라미터, 광분해, 형광 소광 및 Convolutive Voltammetry)

  • El-Daly, S.A.;El-Hallag, I.S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • The photophysical properties of 7-diethylaminocoumarin (DEAC) laser dye have been measured in different solvents. The emission spectrum of DEAC has also been measured in cationic (CTAC) and anionic (SDS) micelles. The laser parameters have been calculated in different solvents namely acetone, dioxane, ethanol and dimethylforamide(DMF). The photoreactivity of DEAC has been studied in $CCl_4$ solvent using 366 nm light. The values of photochemical yield (${\Phi}_c$) and rate constant (k) are determined. The interaction of organic acceptors such as picric acid (PA), tetracyanoethylene (TCNE) and 7,7,8,8-tetracynoquinonedimethane (TCNQ) with DEAC are also studied using fluorescence measurements in acetonitrile ($CH_3CN$). The electrochemical investigation of (DEAC) has been carried out using cyclic voltammetry and convolutive voltammetry combined with digital simulation technique at a platinum electrode in 0.1 mol $L^{-1}$ tetrabutyl ammonium perchlorate (TBAP) in $CH_3CN$ solvent. The electrochemical parameters of the investigated compound were determined using cyclic and convolutive voltammetry. The extracted electrochemical parameters were verified and confirmed via digital simulation method.

The Implementation of Communication Emulate Based on Component For Automation System (자동화시스템을 위한 컴포넌트 기반의 통신 Emulate 구현)

  • Jeong Hwa-Young
    • Journal of Digital Contents Society
    • /
    • v.3 no.2
    • /
    • pp.245-254
    • /
    • 2002
  • Currently, communication field for automation system can be divided by simple serial communication for communication between each internal devices and network base remote control system that is based on TCP/IP. In spite of great development of network, communication part for internal control is using simple RS232 base until present. Also, development techniques of system developed by object oriented program in modular programming techniques of each function unit. Currently, it developed by component base development technique that is parts unit of software. This is presented by the new alternative of software development techniques as techniques to composition independent operation unit including business logic and is connected to development of new system. Therefore, this research implemented internal communication Emulate in RS232C based on GUI that apply development techniques of component base. that is, I maked component to commnication control part between receiving and sending and, as composite it, Control part did to handling between send and receive data.

  • PDF

The effect of smart learning based class on students with low academic achievement level: focusing on 3D application and AR of smart application (스마트러닝기반의 수업이 학업성취수준이 낮은 학생들에게 미치는 효과성 분석: 스마트앱의 3D와 AR 활용을 중심으로)

  • Hong, Ye-Yoon;Im, Yeon-Wook
    • Journal of Digital Convergence
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • The purpose of the study is to investigate the impact and analyze the effect of smart learning based class to on the students with low academic achievement level. The study performed in G University in 2018 among students taking calculus II class. It includes 16 students with low academic achievement level, whose grades were under C in the previous calculus I class. They belonged to special class consisted of very low academic achievement level and had to pass calculus II. 3D and AR were actively used in the class. The result shows that they got visual understanding of space, which revealed through analyzing SNS, mid-term and final examination, lecture evaluation. Also, smart learning based mathematics class utilizing smartphone's application elevated academic achievement level and influenced positively on the interest and attitude toward mathematics regardless of previous academic achievement level.

Development of Wireless Image Transmission System in Subway at 18GHz (18GHz 지하철 무선영상 전송시스템 개발)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Back-Hyun;Nam, Myung-Woo;Lee, Young-Seock;Oh, Myung-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2196-2201
    • /
    • 2010
  • The video transmission system using OFDM method at 18GHz frequency band was developed for wireless video transmission from subway to monitoring center when subway running. It is composed of digital modulation board and RF board. And it has a robust characteristics of multipath fading in subway tunnels at 18GHz. To verify the system, we used spectrum analyzer for analysing the output of transmission system and get the results that it has 350MHz frequency, 8MHz bandwidth and -19dBm channel power. Also we tested video receiving using MPEG-2 encoder and got good quality images.

Extraction of 3D Objects Around Roads Using MMS LiDAR Data (MMS LiDAR 자료를 이용한 도로 주변 3차원 객체 추출)

  • CHOUNG, Yun-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.152-161
    • /
    • 2017
  • Making precise 3D maps using Mobile Mapping System (MMS) sensors are essential for the development of self-driving cars. This paper conducts research on the extraction of 3D objects around the roads using the point cloud acquired by the MMS Light Detection and Ranging (LiDAR) sensor through the following steps. First, the digital surface model (DSM) is generated using MMS LiDAR data, and then the slope map is generated from the DSM. Next, the 3D objects around the roads are identified using the slope information. Finally, 97% of the 3D objects around the roads are extracted using the morphological filtering technique. This research contributes a plan for the application of automated driving technology by extracting the 3D objects around the roads using spatial information data acquired by the MMS sensor.

A CYBER SECURITY RISK ASSESSMENT FOR THE DESIGN OF I&C SYSTEMS IN NUCLEAR POWER PLANTS

  • Song, Jae-Gu;Lee, Jung-Woon;Lee, Cheol-Kwon;Kwon, Kee-Choon;Lee, Dong-Young
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.919-928
    • /
    • 2012
  • The applications of computers and communication system and network technologies in nuclear power plants have expanded recently. This application of digital technologies to the instrumentation and control systems of nuclear power plants brings with it the cyber security concerns similar to other critical infrastructures. Cyber security risk assessments for digital instrumentation and control systems have become more crucial in the development of new systems and in the operation of existing systems. Although the instrumentation and control systems of nuclear power plants are similar to industrial control systems, the former have specifications that differ from the latter in terms of architecture and function, in order to satisfy nuclear safety requirements, which need different methods for the application of cyber security risk assessment. In this paper, the characteristics of nuclear power plant instrumentation and control systems are described, and the considerations needed when conducting cyber security risk assessments in accordance with the lifecycle process of instrumentation and control systems are discussed. For cyber security risk assessments of instrumentation and control systems, the activities and considerations necessary for assessments during the system design phase or component design and equipment supply phase are presented in the following 6 steps: 1) System Identification and Cyber Security Modeling, 2) Asset and Impact Analysis, 3) Threat Analysis, 4) Vulnerability Analysis, 5) Security Control Design, and 6) Penetration test. The results from an application of the method to a digital reactor protection system are described.

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF