Inward Diffusion of Tb Ions and the Magnetic Properties of the Nd-Fe-B Magnets (열처리 조건에 따른 Tb이온의 확산 및 Nd-Fe-B 자석의 자기적 특성)

  • Oh, Seong-Uk;Kim, Dong-Whan;Gong, Gun-Seung;Heo, Young-Woo;Kim, Jeong-Joo;Lee, Joon-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • In this study, the effect of Tb inward diffusion on the magnetic properties of the Nd-Fe-B sintered magnets was studied. After sintering of the magnets, $TbF_3$ slurries were dip-coated on the surface of the samples, then heat-treatment was followed for $TbF_3$ diffusion. The element distribution in the magnets and the diffusion profiles of Tb ions were analyzed by an EPMA (electron probe micro-analyzer). Prolonged heat treatment resulted in a deeper diffusion length of Tb ions. Coercivity of the $1^{st}$ heat-treated sample showed 21.86 kOe, while that of the $1^{st}$, $2^{nd}$ heat-treated and annealed sample revealed 34 kOe.

Evaluation of Treatment Response Using Diffusion-Weighted MAI in Metastatic Spines (척추 전이암에서 확산강조 자기공명 영상을 이용한 치료반응의 평가)

  • Lee, Jang-Jin;Shin, Sei-One
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.30-38
    • /
    • 2001
  • Background: The purpose of this study was to evaluate the usefulness of diffusion-weighted magnetic resonance imaging for monitoring the response to radiation therapy in metastatic bone marrow of the spines. Materials and Methods: Twenty-one patients with metastatic bone marrow of the spines were examined with MRI. Diffusion-weighted and spin-echo MRI were performed in 10 patients before and after radiation therapy with or without systemic chemotherapy, and performed in 11 patients after radiation therapy alone. Follow up spin-echo and diffusion-weighted MRI were obtained at 1 to 6 months after radiation therapy according to patients' condition. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the metastatic bone marrows before and after radiation therapy on conventional spin-echo sequence MRI and diffusion-weighted MRI were evaluated. Bone marrow contrast ratios and signal-to-noise ratios before and after radiation therapy of diffusion- weighted MRI were analyzed. Results: All metastatic bone marrow of the spinal bodies were hyperintense to normal bone marrow of the spinal bodies on pretreatment diffusion-weighted MRI and positive bone marrow contrast ratios(p<0.001), and hypointense to normal spinal bodies on posttreatment diffusion-weighted MRI and negative bone marrow contrast ratios(p<0.001). The signal to noise ratios after treatment decreased comparing with those of pretreatment. Decreased signal intensity of the metastatic bone marrows on diffusion-weighted MRI began to be observed at average more than one month after the initiation of the radiation therapy. Conclusion: These results suggest that diffusion-weighted MRI would be an excellent method for monitoring the response to therapy of metastatic bone marrow of the spinal bodies, however, must be investigated in a larger series of patients with longer follow up period.

  • PDF

A study on wear damage of SKD11 steel material for a cutting mold jig (SKD11 절단금형치구용 소재의 마모손상에 관한 연구)

  • Nam, Ki-Woo;Kim, Cheol-Su;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.5-13
    • /
    • 2016
  • This study is on wear damage of the material for a molding machine that be used at finally cutting of metal beam made in roll forming process of vehicle bump beam process line. SKD11 steel was used with the material for cutting mold jig. In the cutting mold jig, Ti diffusion heat treatment after vacuum heat treatment was carried out for upgrade of surface hardness and anti-wear. Also, the heat treatments by various methods were performed to compare the wear damage degree against above the existing heat treatment. Wear loss and friction coefficient were obtained from wear test. And, micro Vickers hardness values were compared with damaged parts or not of cutting mold jig. Micro Vickers hardness value appeared higher at the undamaged part by Ti diffusion heat treatment. The micro Vickers hardness well followed a two-parameter Weibull probability distribution.

Dynamic Response of Charge Transfer and Recombination at Various Electrodes in Dye-sensitized Solar Cells Investigated Using Intensity Modulated Photocurrent and Photovoltage Spectroscopy

  • Kim, Gyeong-Ok;Ryu, Kwang-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.469-472
    • /
    • 2012
  • Intensity modulated photocurrent spectroscopy and intensity modulated photovoltage spectroscopy were investigated to measure the dynamic response of charge transfer and recombination in the standard, $TiCl_4$-treated and the combined scattering layer electrode dye-sensitized solar cells (DSSCs). IMPS and IMVS provided transit time ($\tau_n$), lifetime ($\tau_r$), diffusion coefficient ($D_n$) and effective diffusion length ($L_n$). These expressions are derived that generation, collection, and recombination of electrons in a thin layer nanocrystalline DSSC under conditions of steady illumination and with a superimposed small amplitude modulation. In this experimental, IMPS/IMVS showed that the main effect of $TiCl_4$ treatment is to suppress the recombination of photogenerated electrons, thereby extending their lifetime. And the Diffusion coefficient of combined scattering layer electrode is $6.10{\times}10^{-6}$ higher than that of the others, resulting in longer diffusion length.

Brain Abscess Showing a Lack of Restricted Diffusion and Successfully Treated with Linezolid

  • Kim, Joo-hyun;Park, Sang-phil;Moon, Byung-gwan;Kim, Deok-ryeong
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • A 59-year-old patient with a history of hepatocellular carcinoma presented with decreased consciousness and left hemiparesis. A rim-enhanced mass lesion without diffusion restriction was observed in contrast-enhanced MRI including diffusion-weighted imaging. Based on these findings, metastatic brain tumor was suspected. However, brain abscess (BA) was diagnosed after multiple bacterial colonies were observed in aspiration biopsy. Initial conventional antibiotic treatment including vancomycin had failed, so linezolid was used as second-line therapy. As a result, infection signs and clinical symptoms were resolved. We report a case with atypical imaging features and antibiotic susceptibility of a BA in an immunocompromised patient undergoing chemotherapy.

Effect of Cu/Al powder mixing on Dy diffusion in Nd-Fe-B sintered magnets treated with a grain boundary diffusion process (입계확산처리된 Nd-Fe-B 소결자석에서 Dy의 확산에 미치는 Cu와 Al 분말의 혼합 효과)

  • Lee, Min Woo;Jang, Tae Suk
    • Journal of Powder Materials
    • /
    • v.23 no.6
    • /
    • pp.432-436
    • /
    • 2016
  • We investigate the microstructural and magnetic property changes of $DyH_2$, $Cu+DyH_2$, and $Al+DyH_2$ diffusion-treated NdFeB sintered magnets with the post annealing (PA) temperature. The coercivity of all the diffusion-treated magnets increases with increasing heat treatment temperature except at $910^{\circ}C$, where it decreases slightly. Moreover, at $880^{\circ}C$, the coercivity increases by 3.8 kOe in Cu and 4.7 kOe in Al-mixed $DyH_2$-coated magnets, whereas this increase is relatively low (3.0 kOe) in the magnet coated with only $DyH_2$. Both Cu and Al have an almost similar effect on the coercivity improvement, particularly over the heat treatment temperature range of $790-880^{\circ}C$. The diffusivity and diffusion depth of Dy increases in those magnets that are treated with Cu or Al-mixed $DyH_2$, mainly because of the comparatively easy diffusion path provided by Cu and Al owing to their solubility in the Nd-rich grain boundary phase. The formation of a highly anisotropic $(Nd,\;Dy)_2Fe_{14}B$ phase layer, which acts as the shell in the core-shell-type structure so as to prevent the reverse domain movement, is the cause of enhanced coercivity of diffusion-treated Nd-Fe-B magnets.

Gamma Knife Radiosurgery for Trigeminal Neuralgia : Review and Update

  • Lee, Seunghoon;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.633-639
    • /
    • 2022
  • Accurate diagnosis of trigeminal neuralgia (TN) is the starting point for optimal treatment. Gamma knife radiosurgery (GKRS) is currently regarded as one of the first-line treatment options for medically refractory TN. GKRS is a less invasive treatment with a low risk of complications than other surgical procedures that provides a favorable pain control Barrow Neurological Institute (BNI) I-IIIb rate of >75% at short-term follow-up. Drawbacks of GKRS include the latency period before pain relief and higher recurrence rate compared with microvascular decompression. Therefore, repeat treatment is necessary if the initial GKRS was effective but followed by recurrence. The concept of dose rate and the biologically effective dose of radiation has been actively studied in radiation oncology and is also applied in GKRS for TN to achieve high safety and efficacy by prescribing the optimal dose. Recent progress in functional imaging, such as diffusion tensor imaging, enables us to understand the pathophysiology of TN and predict the clinical outcome after GKRS. Here, we review TN, GKRS, and recent updates, especially in the concepts of radiation dose, diffusion tensor imaging studies, and repeat treatment in GKRS for TN.

SIMS Study on the Diffusion of Al in Si and Si QD Layer by Heat Treatment

  • Jang, Jong Shik;Kang, Hee Jae;Kim, An Soon;Baek, Hyun Jeong;Kim, Tae Woon;Hong, Songwoung;Kim, Kyung Joong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.188.1-188.1
    • /
    • 2014
  • Aluminum is widely used as a material for electrode on silicon based devices. Especially, aluminum films are used as backside and front-side electrodes in silicon quantum dot (QD) solar cells. In this point, the diffusion of aluminum is very important for the enhancement of power conversion efficiency by improvement of contact property. Aluminum was deposited on a Si (100) wafer and a Si QD layer by ion beam sputter system with a DC ion gun. The Si QD layer was fabricated by $1100^{\circ}C$ annealing of the $SiO_2/SiO_1$ multilayer film grown by ion beam sputtering deposition. Cs ion beam with a low energy and a grazing incidence angle was used in SIMS depth profiling analysis to obtain high depth resolution. Diffusion behavior of aluminum in the Al/Si and Al/Si QD interfaces was investigated by secondary ion mass spectrometry (SIMS) as a function of heat treatment temperature. It was found that aluminum is diffused into Si substrate at $450^{\circ}C$. In this presentation, the effect of heat treatment temperature and Si nitride diffusion barrier on the diffusion of Al will be discussed.

  • PDF

A Study on the Diffusion Barrier at the p/n Junctions of $Bi_{0.5}Sb_{1.5}Te_3/Bi_2Te_{2.4}Se_{0.6} p/n$ Thermoelectric Thin Films (열전 박막 $Bi_{0.5}Sb_{1.5}Te_3/Bi_2Te_{2.4}Se_{0.6} p/n$ 접합에서의 확산 장벽에 관한 연구)

  • Kim, Il-Ho;Lee, Dong-Hui
    • Korean Journal of Materials Research
    • /
    • v.6 no.7
    • /
    • pp.678-683
    • /
    • 1996
  • In the fabrication processes of thin film thermoelectrics, a subsequent annealing treatment is inevitable to reduce the defects and residual stresses introduced during the film growth, and to make the uniform carrier concentration of the film. However, the diffusion-induced atomic redistribution and the broadening of p/n junction region are expected to affect the thermoelectric properties of thin film modules. The present study intends to investigate the diffusion at the p/n junctions of thermoelectric thin films and to relate it to the property changes. The film junctions of p-type(Bi0.5Sb1.5Te3)and n-type(Bi2Te2.4Se0.6)were prepared by the flash evaporation method. Aluminum thin layer was employed as a diffusion barrier between p-and n-type films of the junction. This was found to be an effective barrier by showing a negligible diffusion into both type films. After annealing treatment, the thermoelectric properties of p/n couples with aluminum barrier layer were accordingly retained their properties without any deterioration.

  • PDF

Change in Microstructure and Coating Layer of Al-Si Coated Steel after Conductive Heating (Al-Si 도금강의 통전 가열에 따른 미세조직과 도금층 변화)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.3
    • /
    • pp.107-115
    • /
    • 2021
  • Al-Si coated boron steel has been widely used as commercial hot stamping steel. When the steel is heated at 900~930℃ for 5 min in an electric furnace, thickness of the coating layer increases as a consequence of formation of intermetallic compounds and diffusion layer. The diffusion layer plays an important roll in blunting the propagation of crack from coating layer to base steel. Change in microstructure and coating layer of Al-Si coated boron steel after conductive heating with higher heating rate than electric furnace has been investigated in this study. Conductive-heated steel showed the martensitic structure with vickers hardness of 505~567. Both intermetallic compounds in coating layer and diffusion layer were not observed in conductive-heated steel due to rapid heating. It has been found that the conductive-heating consisting of rapid heating to 550℃ which is lower than melting point of Al-Si coating layer, slower heating to 900℃, and then 1 min holding at 900℃ is effective in forming intermetallic compound in coating layer and diffusion layer.