• 제목/요약/키워드: diffuse light

검색결과 220건 처리시간 0.025초

전이금속 도핑이 ZnO 나노분말의 특성 및 메틸렌블루 광촉매 분해 특성에 미치는 영향 (Effects of transition metal-doping on the properties of ZnO nanoparticles and the photocatalytic degradation of methylene blue)

  • 장한권;오경준;장희동;조국;김동진;최진훈
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.29-35
    • /
    • 2010
  • Transition metals such as V, Fe, and Ni were used to synthesize doped zinc oxide nanoparticles from mixed liquid precursors by using the flame spray pyrolysis (FSP). The effects of dopants on the powder properties such as morphology, specific surface area, crystal structure, and light adsorption were analyzed by TEM, BET, XRD, and UV-Vis diffuse reflection spectrum (DRS), respectively. The results showed that hexagonal wurtzite structured ZnO:M (M = V, Fe, Ni) nanoparticles were successfully synthesized by the FSP. The transition metal-doping resulted in the decrease in its particle size and crystallite size. The UV-vis absorption spectra of ZnO:M nanoparticles were also red-shifted. ZnO:V showed the highest MB degradation of 99.4% under the UV irradiation after 3 hrs.

모발 염색에 따른 광택도의 변화 (Hair dyeing and the consequential change in luster)

  • 박재정;문효승;김종협;김왕기;한상훈
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2011년도 제45차 학술발표회
    • /
    • pp.13-13
    • /
    • 2011
  • Hair luster is a key objective for consumers in the hair care market. Recently, as consumers using hair coloring or bleaching product increase, measurement and quantification of hair luster become more important. A hair visual appearance measurement system called SAMBA can quantitate the luster and effectively separate specular and diffuse light. SAMBA usually has been employed to measure, mainly with the change of shine value, effects of cosmetic treatments on hair shine and surface smothness. We conducted a study on the effect of dyeing and bleaching on the luster, as a result, a strong bleaching caused large decline of the luster. But the large decline of luster was caused by increasing intensity of diffusion and width of chroma peak, not the shine value. The system of dye toning for higher luster can be developed on reference to the peak type of chroma and diffusion depends on kinds and combination of dye.

  • PDF

고상 확산 법에 의한 P-type Zn 확산과 $GaAs_{0.60}P_{0.40}$의 전계발광 특성 (p-type Zn Diffusion using by Solid State Method of $GaAs_{0.60}P_{0.40}$ and the Properties of Electroluminescence)

  • 표진구;임근영;소병문;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.481-485
    • /
    • 2003
  • To diffuse Zn at solid-state, the $SiO_2/ZnO/SiO_2$ wafers was made by PECVD and RF Spotter. Thicknesses of bottom $SiO_2$ and cap $SiO_2$ was about $500{\AA}$ and about $3500{\AA}$. First test was Diffusion temperatures were $760^{\circ}C$, $780^{\circ}C$, and $800^{\circ}C$, and diffusion times were 1, 2, 3, 4, 5, and 6 hr and 2nd test was Diffusion temperatures were $760^{\circ}C$, $720^{\circ}C$, and $680^{\circ}C$, and diffusion times were 1, 2, 3, 4, 5, and 6 hr. LED chips were fabricated by the diffused wafers at Fab. The peak wavelength of all chips showed about $625{\sim}650\;nm$ and red color Main reason for Iv change was by diffusion temperature not diffusion time. The lower temperature was the higher Iv. We thick that these properties is because of the very high diffusion temperature.

  • PDF

New mathematical approach to determine solar radiation for the southwestern coastline of Pakistan

  • Atteeq Razzak;Zaheer Uddin;M. Jawed Iqbal
    • Advances in Energy Research
    • /
    • 제8권2호
    • /
    • pp.111-123
    • /
    • 2022
  • Solar Energy is the energy of solar radiation carried by them in the form of heat and light. It can be converted into electricity. Solar potential depends on the site's atmosphere; the solar energy distribution depends on many factors, e.g., turbidity, cloud types, pollution levels, solar altitude, etc. We estimated solar radiation with the help of the Ashrae clear-sky model for three locations in Pakistan, namely Pasni, Gwadar, and Jiwani. As these locations are close to each other as compared to the distance between the sun and earth, therefore a slight change of latitude and longitude does not make any difference in the calculation of direct beam solar radiation (BSR), diffuse solar radiation (DSR), and global solar radiation (GSR). A modified formula for declination angle is also developed and presented. We also created two different models for Ashrae constants. The values of these constants are compared with the standard Ashrae Model. A good agreement is observed when we used these constants to calculate BSR, DSR, GSR, the Root mean square error (RMSE), Mean Absolute error (MABE), Mean Absolute percent error (MAPE), and chisquare (χ2) values are in acceptance range, indicating the validity of the models.

이산화 티타늄/마이카 복합 재료의 적외선 광반사 특성 (Synthesis and Infrared Light Reflecting Characteristics of TiO2/Mica Hybrid Composites)

  • 길현석;이석우
    • 공업화학
    • /
    • 제27권1호
    • /
    • pp.16-20
    • /
    • 2016
  • 본 연구에서는 $TiO_2$/마이카 혼성 복합 재료의 합성과 적외선 반사 특성에 관한 연구를 수행하였다. 마이카 입자의 존재 하에 아세트산 수용액에서 titanium isopropoxide의 가수 분해 반응과 축합 반응에 의해 $TiO_2$/마이카 복합 재료를 합성하였다. $TiO_2$/마이카 복합 재료의 열처리($600{\sim}1000^{\circ}C$, 1~3 h)에 의해 마이카 표면에 형성된 비결정성 상의 $TiO_2$은 anatase 상을 거쳐 결정성 rutile 상으로 전환되었으며 열처리 조건에 의해 결정의 크기가 제어되었다. FE-SEM 분석, ED-XRF 분석, XRPD 분석을 통하여 마이카와 $TiO_2$/마이카 복합 재료의 물리화학적 특성을 규명하였다. 확산 반사-근적외선 분광 분석을 통하여 측정한 $TiO_2$/마이카 혼성 복합 재료의 근적외선 범위(780~2,500 nm)에서의 일사 반사율은 88.6%로, 순수한 소성 마이카의 86.6%보다 다소 높았다. 따라서 $TiO_2$/마이카 혼성 복합 재료는 높은 광반사율을 나타내는 차열 도료의 안료로 사용할 수 있을 것이다.

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • 황인찬;서관용
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF

The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

  • Park, Soon-Hong;Sung, Sang-Hun;Lee, Seung-Jun;Jung, Min-Kyu;Kim, Sung-Kook;Jeon, Seong-Woo
    • Journal of Gastric Cancer
    • /
    • 제12권2호
    • /
    • pp.99-107
    • /
    • 2012
  • Purpose: Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods: Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results: The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions: The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection.

원발성 결절성 폐실질형 유전분증 1예 (A Case of Primary Diffuse Nodular Pulmonary Amyloidosis Localized in the Lung)

  • 정성권;오준;노양원;공희상;박계영;박정웅;박재경;남귀현;하승연;이한경;정성환
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권3호
    • /
    • pp.365-371
    • /
    • 2000
  • 유전분증은 비정상적인 섬유성 형태의 단백질이 세포 외 조직에 침착하는 질환이고, 원발성 폐유전분증은 매우 드물게 보고되고 있다. 원발성으로 발생한 경우 기관기관지형은 기도폐쇄를 일으킬 경우에 외과적 절제술이나 레이저 치료술로 치료를 해야하고 미만성 폐포격막형인 경우 호흡부전과 객혈 등으로 예후가 나쁘지만, 결절성인 경우에는 대부분 예후가 좋은 편이나, 드물게는 호흡곤란, 중증 객혈, 및 호흡부전을 일으킬 수 있으며 단일 결절일 때는 악성 종양과의 감별 및 치료적 방법으로 수술적 절제가 필요할 수도 있다. 저자들은 타 장기의 침윤이 없이 폐에만 단독으로 침범한 원발성 다발성 결절성 유전분증 1예를 조직검사를 통하여 확진 후 문헌 고찰과 함께 보고하는 바이다.

  • PDF

산화(酸化)티탄 나노입자(粒子)가 담지(擔持)된 칼슘 알루미늄 형광체(螢光體) (Calcium Aluminate Phosphor Supported $TiO_2$ Nanoparticles)

  • ;김진환;강석민;류호진
    • 자원리싸이클링
    • /
    • 제18권4호
    • /
    • pp.24-30
    • /
    • 2009
  • 희토류 원소를 기반으로한 알루미늄산 형광체에 담지된 산화티탄은 졸겔방법 으로 제조되었다. 이렇게 제조된 산화티탄 나노입자의 재료물성을 분석하기 위해 XRD, FT-IR, DRS UV-Vis, TEM 측정을 실시하였다. 형광체에 담지된 산화티탄 입자의 소결 전후의 XRD분석결과는 600도 이상의 온도에서 아나타제에서 루틸로 상변화가 일어나지 않았다. 600도 이상의 온도에서 지속적인(장시간) 열처리 후에도 형광체에 담지된 산화티탄이 결정화도가 높은 아나타제로 존재 하는 것은 형광체 지지체와 담지된 산화티탄의 서로 다른 결정입계에 의하여 결정성장과 상변화에 필요한 치밀화가 억제되기 때문으로 판단된다. DRS측정결과 형광체에 담지된 산화티탄은 산화티탄이 없는 형광체에 비하여 보다 긴 장파로 쉬프트한 것은 밴드갭 에너지의 환원을 나타낸다. 이러한 형광체에 담지된 산화티탄의 FT-IR 스펙트럼은 피크의 위치가 더 높은 파수로 이동하였다. 이것은 산화티탄 입자와 지지체 사이의 공유결합이 관계하기 때문 이라 판단된다. TEM 이미지는 형광체 지지체에 다른 입자 크기로 담지되어 있는 산화티탄의 분산, 결정화 및 입자 형상을 나타낸다.

저조도 환경에 적합한 이색도 반사 모델을 이용한 색 복원 기법 (Color Restoration Method Using the Dichromatic Reflection Model for Low-light-level Environments)

  • 이우람;전우경;전병민
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7324-7330
    • /
    • 2014
  • 미약한 광원 및 조명이 존재하는 환경에서 획득된 저조도 영상에는 많은 색 왜곡이 발생한다. 이러한 색 왜곡은 해당 비전 시스템의 성능 저하를 발생시킬 수 있는 원인이 된다. 따라서 저조도 영상의 원래 색을 찾는 과정은 비전 시스템의 성능 향상을 위한 중요한 과정이다. 이를 위해 본 논문에서는 저조도 영상을 대상으로 한 이색도 반사 모델 기반의 색 복원 기법을 제안한다. 제안한 기법은 이색도 반사 모델을 기반으로 저조도 영상을 확산 반사와 정반사의 영향을 받는 영역으로 구분한다. 이후 각 영역에 미치는 조명 효과를 제거하기 위하여 grey world 기법과 MSRCR 기법을 적용한다. 마지막으로, 두 기법을 적용하여 생성된 결과 영상에 대해 위치별 가중치를 이용하여 두 영상을 조합하여 최종 결과 영상을 생성한다. 본 논문에서는 성능 평가를 위하여 저조도 합성 영상을 사용하였고, 유클리드 거리 및 각 오차를 성능 평가 요소로 활용하였다. 또한 기존에 연구되었던 다양한 기법과의 성능 비교를 수행하여 성능 평가의 객관성을 확보하였다. 다양한 영상 셋을 이용한 실험에서 제안한 기법은 기존의 기법들에 비해 두 성능 평가요소 관점에서 GTD 영상에 가까운 색 복원이 가능함을 보였다.