• Title/Summary/Keyword: differential relay

Search Result 94, Processing Time 0.031 seconds

Distance Relaying Algorithm for Intertie Protection of a Wind Farm Considering the Fault Ride-through Requirement (Fault ride-through 요구를 고려한 풍력발전단지 연계선 보호 거리계전 알고리즘)

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Zheng, Tai-Ying;Kim, Yeon-Hee;Lee, Young-Gui
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1053-1058
    • /
    • 2010
  • A large modern wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. The wind farm intertie protection system should consider a Fault Ride-Through (FRT) requirement for more reliable protection. The wind farm should keep connected to the grid in the case of a grid fault whilst it should be isolated for an intertie fault. This paper proposes a distance relaying algorithm suitable for wind farm intertie protection considering the FRT requirement. The proposed algorithm estimates the impedance based on a differential equation method because the frequency of the voltage and current deviates the nominal frequency. The algorithm extends the reach of Zone 1 up to 100 % of the length of the intertie to implement the FRT requirement. To discriminate an intertie fault from a grid fault, the algorithm uses a voltage blocking scheme because the magnitude of the voltage at the relaying point for an intertie fault becomes less than that for a grid fault. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various fault conditions. The algorithm can discriminate successfully the intertie fault from grid fault and thus helps to implement the FRT requirement of a wind farm.

Development of Mini Magnetic Switch (초소형 전자 개폐기 개발)

  • Lee, Kyung-Ku;Kim, Jun-Ho;Kim, Gyeoo-Mook;Park, Ji-Hong;Jo, Hyun-Kil;Ahan, Kil-Young;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.134-136
    • /
    • 2003
  • This paper proposes moving mechanism theory & magnetic core analysis regarding mini magnetic contactor and differential mechanism & bimetal analysis regarding mini thermal overload relay. In shortage of technique, we have experienced many difficulties in magnetic switch development. By this research, we developed core parts about mini magnetic switch and applied the results to optimum mini magnetic switch development

  • PDF

A Study on Stator Differential Protection Relay (고정자 차동보호계전기에 관한 연구)

  • Park, Chul-Won;Ban, Woo-Hyeon;Gang, Mul-Gyeol;Lee, Won-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.758-759
    • /
    • 2011
  • 대용량 교류발전기는 전력계통의 중요한 요소이다. 발전기의 사고 중 가장 많이 발생하는 부위는 전기자 권선이다. 보호제어시스템의 효율적인 운용과 향후 차세대 ECMS를 위하여 교류발전기의 보호계전분야에 대한 연구가 필요하다. 해외에서 교류발전기의 단락 및 지락 보호에 관한 Standards들이 제정되었고 발전기의 상세 모델링과 내부권선 사고 모의에 대하여도 계속 연구 중에 있다. 본 논문에서는 고정자의 주보호인 비율차동계전방식의 검출방법, 동작영역 및 특성곡선과 정정치 등을 조사한 후 내부 외부고장의 경우 동작 시뮬레이션을 수행하였다.

  • PDF

Computer Based Simulation for Digital Differential Protection Relay of Power Transformer (컴퓨터기반의 변압기 디지털 비율차동계전기 시뮬레이션 알고리즘 개발)

  • Park, Jin-Soo;Cheon, Young-Sig;Park, Il-Ho;Park, Gwan-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.762-763
    • /
    • 2011
  • 19세기말에 차동보호계전방식이 이미 적용되었고 시스템 보호에 가장 먼저 사용되는 방식 중에 하나였다. 이 방식은 고장전력설비의 기기를 보호하기위해 전류의 입출력값을 비교함으로 고장을 검출하는 방법을 사용한다. 결과적으로 비율차동보호방식은 완벽하게 고장구간을 검출할 수 있으므로 전력설비의 중요기기의 주보호로 적합한 시스템이라고 볼 수 있다. 본 논문 변압기의 내/외부사고유형에 따른 전자기계식과 디지털 보호계전기의 동작특성을 컴퓨터기반의 해석 S/W를 이용하여 모델링과 동작특성에 대한 분석을 통해 보호계전기 동작특성의 신뢰성검증과 전력계통을 시뮬레이션하기 위해 구성하였다. 특히, 비율차동특성 보호 알고리즘을 계전기별로 모듈화하기 위한 기본 구조설계에 초점을 맞추었고 외부사고에 대해 각 보호계전기 동작특성을 비교함으로써 보호계전기 응답특성에 검증하는 기초 데이터를 생성하는 과정도 기술하였다.

  • PDF

Efficient Joint Sub-optimal Differential QOSTBC Decoding for Relay Networks (차등 준 시공간 블록 코드를 이용한 중계기 전송 시스템에서 수신 성능 향상 기법)

  • Tao, Yu-Ting;Han, Jae-Shin;Seo, Jong-Soo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.104-105
    • /
    • 2013
  • 차등 시공간 블록 코드 시스템은 다이버시티 이득을 송신단에서 파일럿 삽입이 필요 없이 얻을 수 있는 기술로 주목되고 있다. 특히, 협력 네트워크 시스템에서 서비스 영역을 확장하기 위하여 중계기를 사용하게 되는데 자연스럽게 채널 추정 기법을 고려하지 않은 방법들이 연구 되었다. 본 논문은 차등 준 시공간 블록 코드를 이용한 협력 전송 네트워크에서 ML(Maximum Likelihood) 기반의 준 최적 신호 결합 기법을 제시한다. 모의실험 결과를 통해 제안된 수신 결합 기법은 높은 신호 대 잡음비 환경에서 기존에 널리 사용되는 MRC (Maximum Ratio Combining) 기법보다 5dB이상의 이득을 얻는 것을 보여준다.

  • PDF

Protective Relaying Algorithm for Transformer Using Neuro-Fuzzy based on Wavelet Transform (웨이브렛 변환 기반 뉴로-펴지를 이용한 변압기 보호계전 알고리즘)

  • Lee Jong-Beom;Lee Myoung-Rhun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.242-250
    • /
    • 2005
  • This paper proposes a new protective relaying algorithm using Neuro-Fuzzy and wavelet transform. To organize advanced nuero-fuzzy algorithm, it is important to select target data reflecting various transformer transient states. These data are made of changing-rates of Dl coefficient and RSM value within half cycle after fault occurrence. Subsequently, advanced neuro-fuzzy algorithm is obtained by converging the target data. As a result of applying the advanced neuro-fuzzy algorithm, discrimination between internal fault and inrush is correctly distinguished within 1/2 after fault occurrence. Accordingly, it is evaluated that the proposed algorithm can effectively protect a transformer by correcting discrimination between winding fault and inrushing state.

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet-Transforms and Back-propagation Neural Networks

  • Ngaopitakkul Atthapol;Kunakorn Anantawat
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.365-371
    • /
    • 2006
  • This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a two-winding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using toolboxes on MATLAB/Simulink. Various cases and fault types based on Thailand electricity transmission and distribution systems are studied to verify the validity of the algorithm. It is found that the proposed method gives a satisfactory accuracy, and will be particularly useful in a development of a modern differential relay for a transformer protection scheme.

A Comparative Study on Fault Detection Algorithm of AC Generator (교류 발전기의 고장 검출 알고리즘에 관한 비교 연구)

  • Park, Chul-Won;Shin, Kwang-Chul;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.102-108
    • /
    • 2008
  • AC generator plays an important role of power system. The large AC generator fault may lead to large impacts or perturbations in power system. And then the protection of a generator has very important role in maintaining stability in a power system. In present, the DFT(discrete Fourier transform) based RDR(ratio differential relay) had been widely applied to a internal fault of a generator stator winding. But DFT has a serious drawback. In the course of transforming a target signal to frequency domain, time information is lost. DWT uses a time-scale region. This paper proposes an advanced fault detection algorithm using DWT(discrete Wavelet transform) to enhance the drawback of conventional DFT based relaying. To evaluate the performance of the proposed relaying, we used the test data which were sampled with 720 [Hz] per cycle and obtained from ATP(alternative transient program) simulation. And we made a comparative study of conventional DFT based RDR and the proposed relaying.

Analysis of transient stability of 154KV power systems in Korea by digital computer techniques (디지탈 계산기에 의한 우리나라 154KV계통의 과도안정도 해석)

  • Man-Choon Han;Sang-Hee Park;Young-Chan Kim
    • 전기의세계
    • /
    • v.17 no.4
    • /
    • pp.18-27
    • /
    • 1968
  • Analysis of the transient stability of power systems following disturbances involves many sets of non-linear differential equations. This paper attempts to analyze the transient stability of multi-machine power systems by the step by step method, using the electronic digital computer. The critical switching times and phase angles for the main 154KV transmission system in Korea, are given from the swing curves of the probable conditions. It is concluded that the system is, in general, stable if the relay is cut off within 12 cycles after the fault. However the fault of DAEGU-SANGJU branch, accompanying much real power, makes the system unstable when the raly is cut off within 4 cycles after fault or automatic voltage regulators are equipped in this branch.

  • PDF

A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator (교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.