• 제목/요약/키워드: differential image method

검색결과 280건 처리시간 0.032초

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Target-free vision-based approach for vibration measurement and damage identification of truss bridges

  • Dong Tan;Zhenghao Ding;Jun Li;Hong Hao
    • Smart Structures and Systems
    • /
    • 제31권4호
    • /
    • pp.421-436
    • /
    • 2023
  • This paper presents a vibration displacement measurement and damage identification method for a space truss structure from its vibration videos. Features from Accelerated Segment Test (FAST) algorithm is combined with adaptive threshold strategy to detect the feature points of high quality within the Region of Interest (ROI), around each node of the truss structure. Then these points are tracked by Kanade-Lucas-Tomasi (KLT) algorithm along the video frame sequences to obtain the vibration displacement time histories. For some cases with the image plane not parallel to the truss structural plane, the scale factors cannot be applied directly. Therefore, these videos are processed with homography transformation. After scale factor adaptation, tracking results are expressed in physical units and compared with ground truth data. The main operational frequencies and the corresponding mode shapes are identified by using Subspace Stochastic Identification (SSI) from the obtained vibration displacement responses and compared with ground truth data. Structural damages are quantified by elemental stiffness reductions. A Bayesian inference-based objective function is constructed based on natural frequencies to identify the damage by model updating. The Success-History based Adaptive Differential Evolution with Linear Population Size Reduction (L-SHADE) is applied to minimise the objective function by tuning the damage parameter of each element. The locations and severities of damage in each case are then identified. The accuracy and effectiveness are verified by comparison of the identified results with the ground truth data.

공기주입 직장 확장 F-18 FDG PET/CT의 임상적 유용성 (The Clinical Utility of Rectal Gas Distension F-18 FDG PET/CT)

  • 김진숙;임석태;정영진;김동욱;정환정;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권6호
    • /
    • pp.565-571
    • /
    • 2009
  • 목적: F-18 FDG PET/CT에서 직장에 국소적 섭취 증가를 보이는 환자에서 공기주입 직장확장 영상(rectal gas distension image)의 임상적 유용성을 알아보았다. 대상 및 방법: 2008년 1월부터 2008년 7월까지 F-18 FDG PET/CT를 촬영한 환자 중 공기주입 직장확장 영상을 추가 촬영한 24명의 환자를 대상으로 하였다(남:여=11:13 나이 $62.8{\pm}12.4$세). F-18 FDG 주사 후 1시간째에 촬영한 영상에서 직장 내 국소적인 섭취증가를 보인 환자는 직장 내로 공기주입 후 복부 추가 PET/CT영상을 얻었다. 공기주입 직장확장 영상에서도 지속적으로 관찰되는 섭취에 대해서는 크기와 SUVmax를 측정하였고, 대장내시경과 조직검사로 확진하였다. 결과: 24명의 직장 내 국소 섭취증가를 보인 환자 중 16명은 하부 위장관 악성 종양 환자였고, 2명은 상부 위장관 악성 종양, 2명은 난소암, 3명은 다른 악성 종양(유방암, 갑상선암, 담낭암), 1명은 양성 질환 이었다. 이중 7명은 공기주입 직장확장 영상에서 보이지 않아 생리적 섭취로 간주하였다. 또한 3명의 환자는 직장이 아닌 인접한 다른 장기의 섭취로 확인되었다(2명: 직장방관공간, 1명: 자궁 근종). 공기주입 직장확장 영상에서 지속적으로 섭취를 보였던 17병소 중에서 15병소는 악성 종양으로 확진되었고, 이들의 크기는 $4.7{\pm}2.9\;cm$ (1-12.1 cm), SUVmax는 $16.1{\pm}7.7$ (5.7-28.9)이었다. 2명은 양성질환(1: 선종, 1명: 염증성질환)으로 확인되었으며, 선종으로 확인된 병변은 직장확장 영상에서 1 cm 크기의 유경성(pedunculated) 용종 모양으로 관찰되었다. 염증성 질환으로 확인 되었던 병변 중 하나는 직장확장 영상에서 이전 직장 수술 부분에 국소적으로 섭취가 남아있었으나 섭취정도가 감소하였다. 결론: 공기주입 직장확장 영상은 직장의 국소 병변에 대해 생리적 섭취와 병리적 섭취를 감별하는데 도움을 주며, 직장 병변과 직장 외 병변을 감별해 준다. 또 병변의 직접적인 형태를 관찰할 수 있어 판독의 특이도를 높이는데 도움을 줄 수 있다.

그룹 몰입도 판단을 위한 움직임 동기화 연구 (A Study of the Reactive Movement Synchronization for Analysis of Group Flow)

  • 류준모;박승보;김재경
    • 지능정보연구
    • /
    • 제19권1호
    • /
    • pp.79-94
    • /
    • 2013
  • 최근 문화 예술 분야를 활용하여 고부가가치를 창출하며 지속적으로 발전하는 공연예술 시장 환경 속에서 공연 기획자들이나 투자자들은 공연에서 성공을 하기 위한 객관적인 지표를 원한다. 성공적인 공연을 위해서는 관람객들에게 편의를 제공하여 만족도를 높여 주어야 하며, 따라서 재미와 감동, 가치를 높이는 방안도 모색해야 한다. 기존의 만족도 확인 방법으로는 공연기간, 설문조사, 입소문 등 주관적인 평가가 대부분이다. 이것들은 관람객들의 만족도에 대한 평가 기준이 될 수 는 없다. 최근에는 공연에서 관람객의 몰입 정도가 공연의 주요 성공 요인으로 평가되기 시작했다. 공연에 대한 몰입도가 높으면 만족도도 높아진다는 연구 결과도 있다. 그래서 공연에 대한 관람객의 몰입을 실시간으로 확인하는 지표를 개발하는 것은 관람객들의 만족도를 평가하는데 유용하게 사용될 수 잇다. 기존의 몰입도 추출 연구는 대부분 1인을 대상으로 한 연구들이며 전체 관람객들의 몰입도는 개별 몰입도를 통합하여 측정하여 왔다. 하지만, 공연장에서 관람객들의 몰입도를 개별적으로 측정하기에는 경제적으로나 환경적으로 어려운 상황이다. 이러한 문제를 해결하기 위하여 본 연구에서는, 공연장의 전체 관람객 몰입도를 측정하기 위하여 차영상 기반의 동기화 기법을 활용하는 모형을 제시 한다. 이 기법은 우선 카메라를 통해 관람객 영상을 수집하고, 이를 차영상 기법을 이용하여 동일 장소, 시간 내 관람객들의 움직임 변화량을 측정하여 동기화 여부를 판단하는 것이다. 본 논문에서 동기화가 되었다는 의미는 관람객들이 몰입하고 있을 때, 자극원에 대하여 동시성을 가지고 반응하는 것을 말한다. 이것을 차영상 기법을 통하여 움직임의 변화량으로 환산하고, 이것을 이용하여 동적 동기화와 정적 동기화인지 구분한다. 그런 후 전체 관람객들의 움직임 변화량들을 비교하여 관람객들의 몰입도를 판단하는 모형을 구축하는 것이다. 이 연구에서는 전체 관객의 몰입도 판단 모형을 제시하고, 실제 관객의 반응 데이터를 이용한 평가를 하여 제시한 연구모형이 실제 공연장에서 그룹 관람객들의 몰입도를 측정할 수 있는 것을 확인할 수 있었다.

공간보간법 적용을 통한 산림 종다양성지수의 공간적 추정 - 제1차 산림의 건강·활력도 조사 자료를 이용하여 - (Spatial Estimation of Forest Species Diversity Index by Applying Spatial Interpolation Method - Based on 1st Forest Health Management data-)

  • 이준희;류지은;최유영;정혜인;전성우;임종환;최형순
    • 한국환경복원기술학회지
    • /
    • 제22권4호
    • /
    • pp.1-14
    • /
    • 2019
  • The 1st Forest Health Management survey was conducted to examine the health of the forests in Korea. However, in order to understand the health of the forests, which account for 63.7% of the total land area in South Korea, it is necessary to comprehensively spatialize the results of the survey beyond the sampling points. In this regard, out of the sample points of the 1st Forest Health Management survey in Gyeongbuk area, 78 spots were selected. For these spots, the species diversity index was selected from the survey sections, and the spatial interpolation method was applied. Inverse distance weighted (IDW), Ordinary Kriging and Ordinary Cokriging were applied as spatial interpolation methods. Ordinary Cokriging was performed by selecting vegetation indices which are highly correlated with species diversity index as a secondary variable. The vegetation indices - Normalized Differential Vegetation Index(NDVI), Leaf Area Index(LAI), Sample Ratio(SR) and Soil Adjusted Vegetation Index(SAVI) - were extracted from Landsat 8 OLI. Verification was performed by the spatial interpolation method with Mean Error(ME) and Root Mean Square Error(RMSE). As a result, Ordinary Cokriging using SR showed the most accurate result with ME value of 0.0000218 and RMSE value of 0.63983. Ordinary Cokriging using SR was proven to be more accurate than Ordinary Kriging, IDW, using one variable. This indicates that the spatial interpolation method using the vegetation indices is more suitable for spatialization of the biodiversity index sample points of 1st Forest Health Management survey.

안면 영상처리를 통한 김정일 국방위원장의 건강 상태 분석 (Health Analysis of Kim Jung-Il National Defense Committee Chairman Using Face Image Processing)

  • 이세환;김봉현;가민경;조동욱
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2873-2878
    • /
    • 2009
  • 1990년 동독과 서독이 독일로 통일 된 후 우리나라만이 세계에서 유일한 분단국가로 남아있다. 이로 인해 전 세계적인 관심 및 안전에 대한 의구심을 야기하여 국가 이미지 실추 및 관광 수입의 저하 등 여러 분야로 나쁜 영향을 미치고 있는 것이 현 실정이다. 북한은 사회주의체제 국가로서 국방위원장에 의한 독재 체제를 유지하고 있으며 현재 김정일 국방위원장이 정권을 장악하고 있으나 근래 들어 건강에 대한 이상설과 후계자 미결정으로 정치적 불안감이 커져감에 따라 외교 및 남북 관계에 대한 걱정이 증가하고 있다. 따라서 이 같은 상황에서 김정일 위원장에 대한 건강 정보는 대단히 중요한 자료가 된다. 이를 위해 본 논문에서는 한의학의 진단법인 망진 기법을 적용하여 최근 공개된 김정일 국방위원장의 사진에서 안면 분석을 행하여 실제 김정일 국방위원장의 건강에 대한 정보를 추출해 보고자 한다. 그러나 김정일 국방 위원장의 영상의 경우 동일한 환경에서 촬영된 영상이 아니고 여러 가지 분석을 방해하는 요소가 많기 때문에 색상 보정을 통한 분석 방법과 색상 보정 없이 안면 각 부위에 따른 색차의 차이에 대한 비교를 통해 가장 큰 의혹을 받고 있는 당뇨합병증에 대한 분석을 수행하고자 한다.

도파민운반체 영상의 파킨슨증 감별진단 성능: $^{123}I-FP-CIT$ SPECT 연구 (The Discriminating Nature of Dopamine Transporter Image in Parkinsonism: The Competency of Dopaminergic Transporter Imaging in Differential Diagnosis of Parkinsonism: $^{123}I-FP-CIT$ SPECT Study)

  • 김범산;장성준;어재선;박은경;김유경;김종민;이원우;김상은
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권4호
    • /
    • pp.272-279
    • /
    • 2007
  • 목적: 본 연구는 $^{123}I-FP-CIT$ SPECT을 사용하여 파킨슨증을 구성하는 각 질환군별 차이를 평가하는 것이었다 방법: 본태성진전(64.9$\pm$8.4세, 남:녀 =20:59), 알츠하이머병(69.2$\pm$10.0세, 남:녀=4.4), 파킨슨병(66.4$\pm$9.5세, 남:녀=45:82), 레이소체치매(74.6$\pm$8.4세, 남:녀 =1:8), 그리고 다계통위축증(59.7$\pm$6.7세, 남:녀 = 8:6)을 진단받은 환자 237명과 정상군 18명(60.4$\pm$10.2세, 남:녀=9:9)의 $^{123}I-FP-CIT$ SPECT 영상을 분석하였다. 도파민운반체의 표준뇌지도로 검사자의 영상을 공간정규화한 후, 관심영역을 이용하여 미상핵, 피각의 특이영역 계수와 후두엽의 비특이 영역계수를 측정하여 결합잠재능(binding potential; BP)를 계산하였다. 선조체의 특이영역 계수 및 BP는 미상핵과 피각의계수를 가중평균(weighted mean)하여 구하였다. 그리고 피각과 미상핵의 BP간 비(BP ratio of putamen to caudate;PCR)와 선조체, 미상핵, 그리고 피각의 좌우 비대칭 비(asymmetric index; ASI)를 구하였다. 경과 영상을 시행한 파킨슨병(59.3$\pm$11.2세, 남 녀 = 2:3)에서는 연간 BP 감소를 구하였다. 결과 정상군의 BP는 본태성진전이나 알츠하이머병과는 차이가 없었고, 파킨슨병, 다계통위축증, 그리고 레이소체치매보다는 유의하게 높은 값이었다(p<0.005). 정상군의 PCR은 파킨슨병보다는 통계적으로 높았고, ASI는 낮았다(p<0.005), 파킨슨병은 다경색위축증보다 유의하게 PCR값과 피각 및 선조체의 BP는 낮았으며, ASI는 높았다(p<0.05). 그러나 본태성진전과 알츠하이머병 그리고 파킨슨병과 레이소체치매 간에는 모든 변수에서 유의한 차이를 보이지 않았다. 결론: 도파민 운반체 방사성추적자인 $^{123}I-FP-CIT$와 SPECT 영상을 이용하여 파킨슨증에서 질환군에 따른 차이를 평가 할 수 있었다. $^{123}I-FP-CIT$ SPECT를 이용한 도파민 운반체 영상은 파킨슨증의 감별에 유용할 것이다.

간외담관 초음파검사의 주사방법 개선과 교육 후 주사 습득효과에 관한 연구 (A Study of Technical Approach Methods to Transabdominal Ultrasonography of the Extrahepatic Bile Ducts and of Following Effects from the Scan Training)

  • 이인자;강대현;김보영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.149-159
    • /
    • 2008
  • 목 적: 지금까지의 경복부 초음파를 이용한 간외담관에 대한 검사는 주로 담낭과 간외 담도, 즉 총수담관(CBD)만을 확인하는 수준의 검사가 전부인 것처럼 여겨져 왔다. 그러나 저자들은 임상에서의 다양한 경험을 바탕으로 간외담도의 비정상 확장에 대해 분석할 수 있고, 담도질환 유무 및 관련성을 평가하는데 필요한 기술적 접근 방법에 대한 새로운 이론적 토대를 마련하였다. 이 새로운 이론을 기본으로 신뢰성 있는 검사 성적을 얻기 위하여 일정기간 교육 후 scanning 훈련을 시켜 그 효과를 평가함으로서 담관질환 검사의 새로운 기준을 정립코자 한다. 대상 및 방법: 초음파 교육생 30명을 대상으로 간외담관에 대한 새로운 이론에 근거하여 기술적 접근 방법에 대한 교육을 전수한 후 학생 1인당 3시간(30분${\times}$6회)을 배당하여 scanning 훈련을 집중였다. 교육 방법은 강사와 학생 1:1 방식으로 하였다. Scanning 훈련 후 평가 기준으로 모든 학생에게 5분 내에 간외담관 중에서 좌우 담관으로부터 (1) 담낭관 합류부(간외담관 및 담낭관), (2) 췌장 상부담관, (3) 췌두부내 담관, (4) 유두부내 공통관 등 네 분절을 명확하게 구분된 개념으로 scan하게 한 후 정확도를 평가하였다. 결 과: 기존의 교육과 훈련 방식은 간외담관에 대한 경복부 초음파검사의 신뢰도가 매우 낮고, 췌장 상부 담관에만 국한적으로 영상화할 수 있었다. 그러나 새로운 이론에 근거한 교육과 훈련을 마친 후 성적의 평가는 모든 학생(30명)이 (1) 담낭관 합류부(간외담관 및 담낭관), (2) 췌장 상부담관까지 객관성 있게 접근하였다. 24명의 학생이 (3) 췌두부내 담관 말단까지 접근하였으며, 1명의 학생만이 (4) 유두부내 공통관까지 영상화할 수 있었다. 결 론: 간내외 담관의 평가는 간내인성, 담관성 그리고 병태생리학적 다면 평가가 이뤄져야 하지만, 경복부초음파검사에 의해 간외담관을 유두부내 공통관까지 객관적이고 신뢰성 있게 영상화시킬 수 있다면 단순 감별진단 목적으로 시행하는 ERCP같은 환자에게 고통이 수반된 침습적인 검사를 대폭 줄일 수 있을 것이다. 따라서 저자들이 제시한 새로운 검사방법으로 간외 담관에 대한 기술적 접근 방법을 scanning 훈련하여 임상에 적용하게 된다면 초음파의 객관적인 신뢰도를 높일 수 있을 것으로 생각된다.

  • PDF

장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성 (The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions)

  • 김진숙;임석태;정영진;김동욱;정환정;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권4호
    • /
    • pp.309-316
    • /
    • 2009
  • 목적: $^{18}$F-FDG PET/CT는 다양한 장관내 악성 종양을 발견하는데 높은 민감도를 보이고 있다. 하지만 $^{18}$F-FDG가 다양한 형태로 장관 내 생리적, 병리적 섭취증가를 보이기 때문에 그 특이도는 낮다. 이 연구는 장관 내 국소적인 $^{18}$F-FDG 섭취증가를 보일 때 생리적 섭취와 병리적 섭취를 감별하는 데 있어 추가 지연(dual time point) $^{18}$F-FDG PET/CT의 임상적 유용성을 알아보고자 하였다. 대상 및 방법: 2007년 1월부터 2008년 6월까지 장관 내 국소적인 섭취증가를 보여 추가 지연 촬영 $^{18}$F-FDG PET/CT를 실시한 132명(남:여=77:55, 나이 62.8$\pm$11.6세)을 대상으로 하였다. $^{18}$F-FDG 정맥 주사 후 50-60분 후에 조기 영상을 촬영하였고, 정맥 주사 후 4-5시간에 국소 섭취 증가 부위를 포함하고 있는 복부 부위에 대해 추가 지연 촬영을 실시하였다. 초기 영상에서 보였던 국소적 섭취가 지연 영상에서 보이지 않거나 이동하였을 경우에는 생리적 섭취증가로 간주하였고, 지연 영상에서 지속적으로 관찰되는 섭취증가에 대해서는 대장내시경과 병리조직 검사를 실시하였다. 지연 영상에서 지속적으로 관찰되는 장관 내 섭취에 대해서는 각각 Suvmax값과 조기 영상과 지연 영상의 Syvmax값의 차이($\Delta$%Suvmax)를 계산하였다. 결과: 132명의 환자에서 153개의 국소적 섭취증가병소를 관찰할 수 있었다. 이 중 72개 병소에서는 지연 영상에서 섭취 증가가 사라져 생리적 섭취로 판단할 수 있었다. 조기 영상에서만 보였던 생리적 섭취는 맹장을 포함한 오름 결장에서 가장 많이 관찰되었다. 지연 영상에서도 지속적으로 섭취증가를 보인 81개 병소에서 61개는 악성 종양으로 확진되었고, 14개는 양성 질환으로 확인 되었다. 나머지 6개의 병소는 대장내시경에서 특이소견을 보이지 않아 생리적 섭취로 확인되었다. 악성 종양은 $\Delta$%Suvmax가 20.8%$\pm$18.7%로 통계적으로 유의하게 증가하였고, 반대로 리 악성에서는 3.7%$\pm$24.2%로 감소하였다. 가장 유용한 진단적 가치를 주는 요소는 $\Delta$%Suvmax 임을 확인하였고, 악성과 비악성 질환을 감별하는데 임계수를 -5%로 정하였을 때 가장 좋은 민감도, 특이도, 정확도를 보였다. 결론: $^{18}$F-FDG PET/CT를 이용한 추가 지연 촬영은 생리적 섭취와 병리적 섭취를 감별하는데 있어 검사의 특이도를 높이고 불필요한 검사를 줄일 수 있는 유용한 비침습적 방법으로 생각된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF