• Title/Summary/Keyword: differential gains

Search Result 35, Processing Time 0.02 seconds

Study on Model Identification and Pre-Differential 2-DOF PID Flow Control Algorithm for Cooling Processes (냉각 프로세서의 모델규명 및 선행미분형 2 자유도 PID 유량 제어 알고리즘에 관한 연구)

  • Hwang, I-Cheol;Park, Cheol-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1917-1923
    • /
    • 2010
  • This study focuses on model identification and a 2-DOF PID control algorithm for cooling processes; a pneumatic butterfly-type control valve is used for this purpose. The mathematical model is a transfer function composed of a time delay and a second-order delay system. The control valve is identified as a first-order delay system with a time delay and included in the controlled plant. From the experimental data sets for a demo plant, the model parameters are identified, and the 2-DOF PID control gains are analytically derived by Kitamori's method. We show via a computer simulation and an experimental test that the performance of the proposed 2-DOF PID control system is better than that of a conventional 1-DOF PID control system.

Analysis of the Effects of CO Poisoning and Air Bleeding on the Performance of a PEM Fuel Cell Stack using First-Order System Model (일차계 모델을 이용한 고분자전해질 연료전지 스택의 CO Poisoning 및 Air Bleeding 효과 분석)

  • Han, In-Su;Shin, Hyun Khil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.370-375
    • /
    • 2013
  • We analyze the effects of CO poisoning and air bleeding on the performance of a PEM (polymer electrolyte membrane) fuel cell stack fabricated using commercial MEA (membrane electrode assembly). Dynamic response data from the experiments on the performance of a stack are identified by obtaining steady-state gains and time-constants of the first-order system model expressed as a first-order differential equation. It is found that the cell voltage of the stack decreases by 1.3-1.6 mV as the CO concentration rises by 1 ppm. The time elapsed to reach a new steady state after a change in the CO concentration is shortened as the magnitude of the change in the CO concentration increases. In general, the steady-state gain becomes bigger and the time-constant gets smaller with increasing the air concentration (air-bleeding level) in the reformate gas to restore the cell voltage. However, it is possible to recover 87%-96% of the original cell voltages, which are measured with free of CO, within 1-30 min by introducing the bleed air as much as 1% of the reformate gas into the stack.

Toxico-pathological Study p,p-DDE After Experimental Aerosol Exposed to ICR Mouse (환경호르몬인 p,p-DDE의 흡입 시 ICR 마우스의 폐에 미치는 독성병리학적 연구)

  • Choi Hae-Yun;Jung Tae-Young;Ku Sae-Kwang;Yang Hee-Bog;Lee Hyeung-Sik
    • Toxicological Research
    • /
    • v.21 no.2
    • /
    • pp.151-160
    • /
    • 2005
  • In order to monitor the histological and general profiles of lung after direct expose of p,p-DDE, 1, 5 and 10 mg/ml of p,p-DDE were sprayed to male ICR mouse, and seven days after exposure, changes of body weight, lung weight, clinical signs, histological profiles of lung and total WBC in blood were investigated with changes of total cell number and their differential count in bronchoalveolar lavage fluid (BALF). In the present study, a significant and dosage-dependent decrease of body weight was detected in p,p-DDE exposed groups and body weight gains during observational periods (7 days) were also significantly and dosage-dependently decreased in p,p-DDE exposed groups compared to that of vehicle control group. In addition general depression signs were detected in all p,p-DDE exposed groups with dosage-dependent manners, and lung weights were also increased in p,p-DDE exposed groups. Congestion, hemorrhage and severe exudate were observed in the lung of p,p-DDE exposed groups with sarcomatous changes and these signs were also showed by dosage-dependent manners. In addition, foreign body pneumonia signs were observed in the lung of p,p-DDE exposed groups in histological levels. The percentage of ALSA (Area of luminal surface of alveoli) was also significantly and dosage-dependently decreased in p,p-DDE exposed groups and total blood WBC and BALF cell numbers were significantly and dosage-dependently increased in p,p­DDE exposed groups compared to that of vehicle control group and increase percentage of neutrophil, eosinophil, and lymphocyte in BALF were monitored in p,p-DDE exposed groups compared to that of vehicle control group. In conclusion, severe allergic response and/or foreign body pneumonitic changes were induced by direct exposure of p,p-DDE containing beverage. So it is considered that strong and powerful regulation was need to control production of residence of environmental pollutant especially to p,p-DDE.

Block-Based Transform-Domain Measurement Coding for Compressive Sensing of Images (영상 압축센싱을 위한 블록기반 변환영역 측정 부호화)

  • Nguyen, Quang Hong;Nguyen, Viet Anh;Trinh, Chien Van;Dinh, Khanh Quoc;Park, Younghyeon;Jeon, Byeungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.746-755
    • /
    • 2014
  • Compressive sensing (CS) has drawn much interest as a new sampling technique that enables signals to be sampled at a much lower than the Nyquist rate. By noting that the block-based compressive sensing can still keep spatial correlation in measurement domain, in this paper, we propose a novel encoding technique for measurement data obtained in the block-based CS of natural image. We apply discrete wavelet transform (DWT) to decorrelate CS measurements and then assign a proper quantization scheme to those DWT coefficients. Thus, redundancy of CS measurements and bitrate of system are reduced remarkably. Experimental results show improvements in rate-distortion performance by the proposed method against two existing methods of scalar quantization (SQ) and differential pulse-code modulation (DPCM). In the best case, the proposed method gains up to 4 dB, 0.9 dB, and 2.5 dB compared with the Block-based CS-Smoothed Projected Landweber plus SQ, Block-based CS-Smoothed Projected Landweber plus DPCM, and Multihypothesis Block-based CS-Smoothed Projected Landweber plus DPCM, respectively.

Studies on the Selection Response of Generation for Egg Production in Single Comb Leghorn (백색 레그혼종 순종계통의 산란능력에 있어서 세대별 선발반응에 관한 연구)

  • 이학교;최철환;박무균;이수헌;박태진
    • Korean Journal of Poultry Science
    • /
    • v.19 no.4
    • /
    • pp.187-195
    • /
    • 1992
  • This study carried out to investigate selection response of pure line population of layer chicken. Data for two layer pure line of Single Comb White Leghorn were collected from 1986 to 1991. Primary selection criteria were egg number to 270 days of age (EN270), egg weight(BW270), body weight (BW270) at 270 days of age and the days of the 1st egg(SM). The results obtained in this study are summarized as follows ; 1. Mean phenotypic values of two strains were decreased by 1.94 day(K), 1.320ay(F) for SM and increased by 0.09g(K), -0.05g(F) for EW 270 and 0.56(K), -0.78(F) for EN270. 2. The ratio of a realized selection differential to expected selection differentials for SM (sexual maturity), EW 270, and BW 270 were not significantly decreased during 5 generations. 3. Heritability were estimated from sib analysis. The means of estimates were 0.28(F), 0.39(K) for BW270, and 0.25(F), 0.29(K) for EN270 and 0.51(F), 0.48(K) for EW270. 4. The genetic gains were estimated by method of selection index in retrospect on the basis of selection differentials. EN270 and EW270 were found to increase by 2.01(F), 2.25(K) and 0.54 (F), 0.65(K) per generation.

  • PDF