• 제목/요약/키워드: differential fault analysis

검색결과 59건 처리시간 0.03초

교류발전기 보호를 위한 고장검출 알고리즘의 비교 분석 (A Comparative Analysis of fault Detection Algorithm for AC Generator Protection)

  • 박철원;신광철;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.75-77
    • /
    • 2007
  • Current percentage differential relaying has been recognized as the principal basis of main protection for stator windings of AC generator. The DWT has merit of obtaining frequency characteristics in time domain. In order to compensate for DFT's defects, we proposed fault detection algorithm using DWT. This paper describes a comparative analysis about conventional DFT-based DFR and advanced DWT-based relaying.

  • PDF

Security Analysis of the Whirlpool Hash Function in the Cloud of Things

  • Li, Wei;Gao, Zhiyong;Gu, Dawu;Ge, Chenyu;Liao, Linfeng;Zhou, Zhihong;Liu, Ya;Liu, Zhiqiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.536-551
    • /
    • 2017
  • With the advancement and deployment of leading-edge telecommunication technologies for sensing and collecting, computing related information, Cloud of Things (CoTs) has emerged as a typical application platform that is envisioned to revolutionize the daily activities of human society, such as intelligent transportation, modern logistics, food safety, environmental monitoring, etc. To avoid any possible malicious attack and resource abuse, employing hash functions is widely recognized as one of the most effective approaches for CoTs to achieve message integrity and data authentication. The Whirlpool hash function has served as part of the joint ISO/IEC 10118-3 International Standard by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC). In this paper, we propose an effective differential fault analysis on Whirlpool in the byte-oriented random fault model. The mathematical analysis and experimental results show that 8 random faults on average are required to obtain the current 512-bit message input of whirlpool and the secret key of HMAC-Whirlpool. Our work demonstrates that Whirlpool and HMAC-Whirlpool are both vulnerable to the single byte differential fault analysis. It provides a new reference for the security analysis of the same structure of the hash functions in the CoTs.

단층 및 파쇄대가 분포하는 Fill Dam 기초의 보강대책 (Geotechnical treatment for the fault and shattered zones under core foundation of fill dam)

  • 김연중;최명달
    • 지질공학
    • /
    • 제2권1호
    • /
    • pp.19-35
    • /
    • 1992
  • 화강편마암을 지반으로 하는 지역의 Fill Dam 코어기초에 3-12m 폭의 단층대와 40여m 폭의 단층파쇄대가 신선한 암반사이에 분포하며, 이들 각각의 암반의 탄성특성은 현저한 차이를 보인다. 평판재하시험 및 시추공내 변형시험 등의 현장 원위치 시험결가 신선한 암반의 변형계수는 $42,000~168,000kg/\textrm{cm}^2$의 범위를 보이나 단층대의 변형계수는 $963~2,204kg/\textrm{cm}^2$, 파쇄대에서는 $1,238~2,098kg/\textrm{cm}^2$의 범위를 나타낸다. 이와 같이 큰 차이의 변형계수값을 갖는 단층대 및 단층파쇄대와 신선한 암반 사이에는 댐 성토 후 부등침하가 예상된다. 따라서 이에 대한 보강을 위하여 증분식 유한요소 프로그램인 FEADAM 84를 이용한 지반과 보강에 따른 변위 등을 검토하였다. 이때 구성된 유한요소망은 지표조사 및 시추조사에서 확인된 불연속면이 기하학적 분포특성을 고려하였다. 유한요소 해석을 통하여 계산된 단층대와 신선한 암반 사이의 보강 전 부등침하량은 약 6cm에 달하며, 콘크리트 치환 보강 후에는 0.5cm 이내로 나타났다.

  • PDF

Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.213-217
    • /
    • 2008
  • The flux-lock type superconducting fault current limiter(SFCL) can apply the magnetic field into the high-$T_C$ superconducting(HTSC) element by adopting the magnetic field coil in its third winding. To apply the magnetic field into the HTSC element effectively, the capacitor for LC resonance is connected in series with the magnetic field coil. However, the current waveform of third winding for the application of the magnetic field is affected by the LC resonance condition for the frequency of the source voltage and can affect the waveform of the limited fault current. In this paper, the current waveform of the third winding in the flux-lock type SFCL according to LC resonance condition during a fault period was analyzed. From the differential equation for its electrical circuit, the current equation of the third winding was derived and described with the natural frequency and the damping ratio as design parameters. Through the analysis according to the design parameters of the third winding, the waveform of the limited fault current was confirmed to be influenced by the current waveform of the third winding and the design condition for the stable fault current limiting operation of this SFCL was obtained.

Position Error Analysis of Carrier-based DGNSS Systems Under Ephemeris Fault Conditions

  • Min, Dongchan;Kim, Yunjung;Lee, Jiyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제10권4호
    • /
    • pp.263-269
    • /
    • 2021
  • The carrier-based differential global navigation satellite system (CD-GNSS) has been garnering significant attention as a promising technology for unmanned vehicles for its high accuracy. The CD-GNSS systems to be used for safety-critical applications should provide a certain level of integrity. The integrity of these systems must be analyzed under various conditions, including fault-free and satellite fault conditions. The systems should be able to detect the faults that can cause large biases on the user position errors and quantify the integrity risk by computing the protection level (PL) to protect the user against the faults that are left undetected. Prior work has derived and investigated the PL for the fault-free condition. In this study, the integrity of the CD-GNSS system under the fault condition is analyzed. The position errors caused by the satellite's fault are compared with the fault-free PL (PL_H0) to verify whether the integrity requirement can be met without computing the PLs for the fault conditions. The simulations are conducted by assuming the ephemeris fault, and the position errors are evaluated by changing the size of the ephemeris faults that missed detection. It was confirmed that the existing fault monitors do not guarantee that the position error under the fault condition does not exceed the PL_H0. Further, the impact of the faults on the position errors is discussed.

발전기의 고장 판별을 위한 웨이브릿 변환의 적용 (Application of Wavelet Transform for Fault Discriminant of Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.35-40
    • /
    • 2015
  • Generators are the most complex and expensive single element in a power system. The generator protection relays should to minimize damage during fault states and must be designed for maximum reliability. A conventional CDR(Current Differential Relaying) technique based on DFT(Discrete Fourier Transform) filter have the disadvantages that the time information can lead to loss in the process of converting the signal from the time domain to the frequency domain. A WT(Wavelet transform) and WT analysis is known that it is possible with the local analysis of the fault and transient signal. In this paper, to overcome the defects in the DFT process, an application of WT for fault detection of generator is presented. This paper describes an selection of mother Wavelet to detect faults of generator. Using collected data from the fault simulation with ATPdraw, we analyzed the several mother Wavelet through the course of MLD(multi-level decomposition) using MATLAB software. Finally, it can be seen that the proposed technique using detail coefficient of Daubechies level 2 which can be fault discriminant of generator.

스코트 변압기 보호계전기 오동작 사례분석 및 개선방안 고찰 (A Study on SCOTT Transformer Protection Relay Malfunction Case and Improvement Methodology)

  • 이종화;노영환
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.394-399
    • /
    • 2017
  • 본 국내 교류전철변전소에서는 주변압기 2차측의 위상각이 $90^{\circ}$인 단상 전원을 얻도록 한 스코트 결선 변압기를 설치 운용 하고 있다. 변압기 보호계전기는 내부에서 고장이 발생하는 경우 변압기 전단에서 전력을 차단시키고 변압기 외부 계통의 사고나 일반차량 운행의 경우에는 동작하지 않아야 한다. 정확한 고장의 판단으로 오동작을 줄이는 것이 전력계통을 안정적으로 유지하고 신뢰성을 향상시키는 측면에서 매우 중요하다. 주 변압기 내부 고장 검출장치로는 브흐홀쯔계전기와 비율차동계전기를 설치하여 변압기를 보호하고 있지만 비율차동계전기의 오동작으로 인해 보호기능을 비활성화 시켜놓은 상태로 운용하는 사례가 있다. 본 논문에서는 스코트 변압기의 특성과 비율차동계전기의 특성을 제시하고 보호계전기의 오동작 사례를 분석하였다. 이를 위해 전력계통 해석프로그램을 이용하여 스코트 변압기에 사용되는 비율차동계전기를 모델링하고 A변전소의 Comtrade 파일로 저장된 고장파형을 입력데이터로 사용하여 동작여부를 판단하여 고조파 분석을 수행하였다. 또한, 고장파형 분석을 통해 오동작 사례에 대한 개선 방안을 도출하고자 한다.

Security Analysis of the PHOTON Lightweight Cryptosystem in the Wireless Body Area Network

  • Li, Wei;Liao, Linfeng;Gu, Dawu;Ge, Chenyu;Gao, Zhiyong;Zhou, Zhihong;Guo, Zheng;Liu, Ya;Liu, Zhiqiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권1호
    • /
    • pp.476-496
    • /
    • 2018
  • With the advancement and deployment of wireless communication techniques, wireless body area network (WBAN) has emerged as a promising approach for e-healthcare that collects the data of vital body parameters and movements for sensing and communicating wearable or implantable healthful related information. In order to avoid any possible rancorous attacks and resource abuse, employing lightweight ciphers is most effective to implement encryption, decryption, message authentication and digital signature for security of WBAN. As a typical lightweight cryptosystem with an extended sponge function framework, the PHOTON family is flexible to provide security for the RFID and other highly-constrained devices. In this paper, we propose a differential fault analysis to break three flavors of the PHOTON family successfully. The mathematical analysis and simulating experimental results show that 33, 69 and 86 random faults in average are required to recover each message input for PHOTON-80/20/16, PHOTON-160/36/36 and PHOTON-224/32/32, respectively. It is the first result of breaking PHOTON with the differential fault analysis. It provides a new reference for the security analysis of the same structure of the lightweight hash functions in the WBAN.

디지탈 계산기에 의한 우리나라 154KV계통의 과도안정도 해석 (Analysis of transient stability of 154KV power systems in Korea by digital computer techniques)

  • 한만춘;박상희;김영찬
    • 전기의세계
    • /
    • 제17권4호
    • /
    • pp.18-27
    • /
    • 1968
  • Analysis of the transient stability of power systems following disturbances involves many sets of non-linear differential equations. This paper attempts to analyze the transient stability of multi-machine power systems by the step by step method, using the electronic digital computer. The critical switching times and phase angles for the main 154KV transmission system in Korea, are given from the swing curves of the probable conditions. It is concluded that the system is, in general, stable if the relay is cut off within 12 cycles after the fault. However the fault of DAEGU-SANGJU branch, accompanying much real power, makes the system unstable when the raly is cut off within 4 cycles after fault or automatic voltage regulators are equipped in this branch.

  • PDF

사이드 채널 공격에 대한 스마트카드 안전성의 실험적 분석 (Development of Side Channel Attack Analysis Tool on Smart Card)

  • 한동호;박제훈;하재철;이성재;문상재
    • 정보보호학회논문지
    • /
    • 제16권4호
    • /
    • pp.59-68
    • /
    • 2006
  • 스마트카드에 내재된 암호 알고리즘이 이론적으로 안전하더라도 실제 구현 환경에 따라 사이드 채널 공격에 취약하다는 사실이 근래에 알려졌다. 본 논문에서는 스마트카드에 구현된 암호 알고리즘의 안전성을 분석할 수 있는 툴을 직접 개발하여 현재 상용 중인 칩을 탑재한 스마트카드에 사이드 채널 공격 중 가장 강력한 공격 방법으로 알려진 전력분석공격과 오류주입공격을 적용하여 안전성 분석을 하였다. 전력분석공격은 대칭키 암호 시스템에 적용하기 쉬운 차분전력분석 공격을 SEED와 ARIA에 대해서 적용하였고, 오류주입공격은 스마트카드의 동작 클럭과 전원을 차단하는 방법으로 CRT기반의 RSA에 적용하였다. 공격 결과 대상 대응책이 없는 경우의 전력분석공격은 가능하지만 오류주입공격은 칩 내부에 사전 방어대책이 마련되어 있어 사이드 채널 공격에 안전했다.