• 제목/요약/키워드: differences in temperature and humidity

검색결과 272건 처리시간 0.023초

Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가 (A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room)

  • 송민정;신훈
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.

온돌환경이 수면시의 생리반응엔 미치는 영향 -봄철 수면시 침실내 온열환경과 침상기후- (Effect of Ondol Environment on Physiological Regponseg during Sleeping (II) The Actual Conditions of Bedclimate in Spring -)

  • 이순원;권수애
    • 한국의류학회지
    • /
    • 제21권3호
    • /
    • pp.516-523
    • /
    • 1997
  • The actual conditions of bedclimate are investigated depending on the regions and housing styles used on ondol in spring. Sixty healthy men and women (30 of them live in apartment and 30 of them live in detached house, 20 of them live in Wonju, 20 of them live in Cheongiu and 20 of them live in Pusan). The results are as follows: 1) The differences of bedclothes thickness between spring and autumn were not significant. weight of sleep-wear in spring was less than those in the autumn. 2) In the spring, the temperature and humidity of bedroom, floor, on/under the mattress, were lower and the temperature inside the sleep-wear was higher than those in the autumn. 3) The differences of the temperature and humidity of bedroom, the bed climate, and the clothing microclimate were significant by the regions and housing styles in spring. The temperature of bedroom and inside sleep-wear, the humidity of bedroom and inside sleep- wear in the apartment were higher than those in the detached house. 4) The differences of comfort sensation on the bedroom conditions was significant by the regions, and the differences of thermal sensation was significant by the housing styles. Most subjects perceived warm and dry but comfortable.

  • PDF

간헐공조 전시관내 유물 진열장의 온·습도 환경 분석 (Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning)

  • 이선명;임보아;김서진
    • 보존과학회지
    • /
    • 제29권4호
    • /
    • pp.311-320
    • /
    • 2013
  • 조사 대상인 유물 진열장은 온도 변화에 대응한 조온기능이 미약한 반면 조습 능력이 비교적 높았다. 유물 진열장 내부의 연평균 온 습도는 $18.8^{\circ}C$, 60.3% 로 전시실에 비해 온도는 낮고 습도는 높은 분포를 나타냈다. 또한 온도는 계절변화에 따라 변동률이 높은 반면 습도는 계절별 평균값이 59~61%로 일정하게 유지되었다. 여름철에는 전시실과 마찬가지로 고온고습 분포를 나타냈고 공조기 가동에 따른 온도의 하강은 습도를 상승시켰으며. 겨울철에는 공조기 가동에 따라 전시실과 유물 진열장 간 온 습도의 차이가 커져 수분 문제가 제기되었다. 유물 진열장 내부 온 습도에 대한 PI는 18.0%로 전시물 보존을 위한 적정 온 습도 조성률이 매우 저조하였다. 특히 여름철과 겨울철은 PI가 1% 미만으로 진열장 내 철저한 온습도 관리가 필요할 것으로 판단된다.

신발사이즈가 신발 내적환경(內的環境)에 미치는 영향(影響) (Effects of Shoe Sizes on the Inner Environment of Shoes)

  • 유현;심부자
    • 패션비즈니스
    • /
    • 제6권4호
    • /
    • pp.151-162
    • /
    • 2002
  • This study aims to reveal the effects of shoe size room on the inner environment of shoes by examining the changes of footskin temperature, temperature and humidity of the shoes, and psychological responses. The following conclusions were made: 1. Skin temperature had significant differences according to shoe sizes in the inner foot parts (right/left) and the outer foot part (left). As time went, skin temperature was distributed as follows: Type A > Type C > Type B. 2. Skin temperature appeared in the following order: instep > inner foot > outer foot. 3. The temperature within the shoes had significant differences: Type A > Type C > Type B. But no significance was recognized in the humidity within the shoes: Type B > Type C > Type A. 4. Some significance was noticed in the psychological responses of size fitness and comfortableness. In size fitness, Type B was responded to be fitting, Type A little small, and Type C rather big. Moisture had similar changes according to three shoe sizes, but humid was the response as time went. Comfortableness appeared in the order of Type C > Type B > Type A.

쾌적 환경에서 헤어스타일 유형이 인체 생리 반응에 미치는 영향 (Effects of Hair Style on Human Physiological Response in a Thermal Neutral Environment)

  • 김명주
    • 한국지역사회생활과학회지
    • /
    • 제21권1호
    • /
    • pp.117-124
    • /
    • 2010
  • Recently, research on variables associated with hair styles are increasing with the spreading of total coordinated intention in the fields of clothing and cosmetology. In the present study, we focused on examining the skin temperature on the scalp(the vertex, temporal, and occiput), humidity on the occiput, skin temperatures (the forehead, back of ear, back of neck, upper back, abdomen, forearm, hand, thigh, calf, and foot), rectal temperature, total body mass loss by hair styles in a thermal neutral environment. Four young females participated as subjects. For a certain period, each subject had the five different hair styles in a random order: (1)Straight short hair(SS), (2)Perm waved short hair(PS), (3) Straight long hair(SL), (4)Perm waved long hair(PL), (5)Ponytail style(PT). Subjects wore briefs, bra, shirts with long sleeves, long legged training pants, and socks. The environmental variables of a climatic chamber were kept constant at $21{\pm}0.5^{\circ}C$ of air temperature and 55${\pm}$5%RH of air humidity. The results indicated the following: The skin temperature and humidity on the scalp did not show any significant differences among five different hair styles, but straight long hair style(SL)was the highest on the vertex, temporal, and occiput. The temporal skin temperature($29.8\sim30.8^{\circ}C$) was the highest, while the vertex skin temperature($28.7\sim30.1^{\circ}C$) was the lowest. Humidity on the occiput was the highest in the perm waved long hair style(PL). The back of ear skin temperature was significantly lower in the ponytail style(PT) than in the other four hair styles(p<.001). In the straight long hair style(SL), the skin temperature on the back of the neck and on the upper back were significantly higher than those of the other four hair styles(p<.01). Mean skin temperature and rectal temperature had no significant differences among hair styles. Total body mass was the highest in the perm waved long hair style(PL)(p<.05). We acquired fundamental data to enable the improvement of the current hair clinic system, wigs, functional hats, and helmets.

국보 제24호 석굴암의 보존환경 (Investigation on Conservation Environment of the Seokguram Grotto (National Treasure No. 24))

  • 홍정기;엄두성
    • 보존과학연구
    • /
    • 통권24호
    • /
    • pp.169-184
    • /
    • 2003
  • Yearly mean temperature and relative-humidity of the Seokguram Grotto was measured $19~23^{\circ}C$, 40~44% from May, 1998 to December,2002. The measurement has little differences comparing to the optimum guideline (temperature : $20^{\circ}\pm2^{\circ}C$, relative-humidity : $50^{\circ}\pm5%$). It is necessary to increase humidity in the Seokguram Grotto during winter because of heating and decrease the temperature during summer because of a higher temperature of outside. In addition, the diurnal range keep in $4^{\circ}C$ of temperature and in 10% of relative-humidity. Yearly mean concentration of $CO_2$(carbon dioxide) was measured538~658ppm that is higher than concentration of normal atmosphere(360 ppm). The $CO_2$ has an cumulative effect on the surface of stone cultural properties as a form of carbonic acid($H_2CO_3$) after reaction with water. HVAC (Heating, Ventilation and Air Conditioning) system should be operated to maintain ideal state for the preservation according to the optimum guideline. Also, the entrance into the Seokguram Grotto should be controlled to prevent a sudden fluctuation of humidity and temperature. Human could carry small particles like a microdust, microbe, etc., into the Seokguram Grotto and also could damage the surface by a direct touch.

  • PDF

하복의 온열생리학적 기초연구 (The Basic Studies of Thermal Physiology for Summer Wears)

  • 성수광;정현옥
    • 한국의류학회지
    • /
    • 제9권2호
    • /
    • pp.57-65
    • /
    • 1985
  • In the experiment with a basic material for the design of summer wear that comfort can be obtained in temperature, to get individual differences, clothing styles (slacks, skirt), material differences(T/C, cotton), and the contrast between when naked and dressed, when two healthy females were dressed four kinds of summer wear as an object of experiment under the regular warm temperature environmental condition (24, 28, 32, $36^{\circ}C$, $60\pm10\%$ RH), the measurement of physiological, phychological change was taken and the result goes as follow; 1. Mean skin temperature rose by clothing, body weight loss decreased below $32^{\circ}C$, thermal sensation changed toward low temperature by $2\~3^{\circ}C$. 2. Mean skin temperature, body weight loss, the lowest blood pressure above $32^{\circ}C$, under-clothing temperature, and thermal sensation increased when in slacks to be compared with when in skirt. 3. Ambient temperature had a great effect on mean skin temperature, body weight loss, respiration, clothing surface temperature, under-clothing temperature and humidity, thermal sensation, etc. 4. It was admitted that pulse, thermal sensation, comfort show different individuality. 5. It was recognized that the lowest blood pressure, clothing surface temperature, under. clothing humidity differ according to the kinds of clothing. 6. A comfortable ambient temperature in clothing summer wear was about $27\~28^{\circ}C$.

  • PDF

토마토 단동온실에서 공기순환팬 설치 방법에 의한 온실 내 온습도 분포 분석 (Analysis of Temperature and Humidity Distributions according to Arrangements of Air Circulation Fans in Single-span Tomato Greenhouse)

  • 이태석;강금춘;백이;문종필;오성식;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.277-282
    • /
    • 2016
  • 본 연구는 폭 7m, 길이 25m, 동고 3.2m의 토마토를 재배하는 온실에 공기순환팬을 설치하고 순환팬이 온실 내 온도 및 습도 분포에 미치는 영향을 조사하였다. 기존의 순환팬 설치 기준(ASAE, 1997)을 참고하여 시험온실에 순환팬 10대를 2열 및 다른 방향으로 설치하여 18시부터 다음날 8시까지 온실 내 온습도를 측정하였다. 온실 내 온습도는 온실을 9개의 격자망으로 나눈 후 온실 중앙부에서는 0.7m, 1.7m 및 2.7m 높이, 온실 좌우측에는 0.7m, 1.7m 높이에 센서를 설치하였다. 공기순환 팬을 사용하지 않았을 때 온실 상하부의 온도 및 습도의 평균값은 $14.7^{\circ}C$, 74.8%와 $13.0^{\circ}C$, 85.6%로 온습도 차는 평균적으로 $1.7^{\circ}C$, 10.8% 발생하였다. 공기순환팬 10대를 2열 및 다른 방향으로 설치하여 운용했을 때 온실 상하부의 온습도는 $14.6^{\circ}C$, 75.9%와 $14.5^{\circ}C$, 79.1%로 온습도 차는 각각 $0.1^{\circ}C$, 3.2%였으며 순환팬을 사용하지 않았을 때와 비교하여 온실 상하부의 온도 및 습도 차가 감소하였다. 순환팬을 6대 및 5대로 줄여서 운용했을 때 온실 상하부의 온습도 차는 각각 $0.3^{\circ}C$, 3.4%와 $0.3^{\circ}C$, 4.0%로 나타나 순환팬 10대를 사용했을 때와 비슷한 효과를 보였다. 순환팬 10대를 2열 및 같은 방향으로 설치했을 때의 온실 상하부의 온습도 차는 $0.5^{\circ}C$, 4.9%로 팬을 다른 방향으로 설치했을 때보다 온습도 차가 크게 나타났다. 온실 좌우측면, 전후면의 온습도 차를 살펴보면 순환팬을 사용하지 않았을 때 좌우 측면의 온습도 차는 $0.3^{\circ}C$, 1.7%로 작아 팬을 사용했을 때와 큰 차이가 없었으나 순환팬을 사용하지 않았을 때 $1.0^{\circ}C$, 4.2%로 나타났던 전후면의 온습도 차는 순환팬을 사용함으로써 감소하였다. 이는 공기순환팬이 온실 내 공기를 순환시켜 온풍난방 시 상부에 정체된 더운 공기나 열손실로 인해 온도가 다른 공기를 교반시킴으로써 온도 및 습도 차가 감소한 것이다. 폭 7m, 길이 25m, 동고 3.2m인 단동온실에서 날개 크기 230mm, 풍량 $11m^3/min$의 공기순환팬을 사용하고자 할 때는 순환팬 5대를 2열로 설치하되 각 열을 방향을 다르게 하고 9m 간격으로 설치하여 운용하는 것이 가장 경제적이고 효과적일 것이다.

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향 (Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors)

  • 한진구;노영만;김현욱
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF