• Title/Summary/Keyword: dialysis

Search Result 706, Processing Time 0.037 seconds

Efficacy and Safety of Cinacalcet for Secondary Hyperparathyroidism in Dialysis Patients and Drug Use Evaluation (투석환자의 이차성 부갑상선 기능 항진증 치료에서 cinacalcet의 유효성과 안전성 및 사용 적정성 평가)

  • Seo, Hee Nam
    • Korean Journal of Clinical Pharmacy
    • /
    • v.23 no.2
    • /
    • pp.142-150
    • /
    • 2013
  • Background: Secondary hyperparathyroidism (SHPT) is common in patients with chronic kidney disease, affecting most of those who are receiving dialysis. Cinacalcet, a novel calcimimetic, targets the calcium-sensing receptor to lower PTH levels in dialysis patients. Objective: This study aimed to assess efficacy, safety and appropriateness of use of cinacalcet in dialysis patients. Method: This retrospective study was performed on total 24 cases with identified intact parathyroid hormone (iPTH), serum calcium and phosphorus levels before and 4 weeks after cinacalcet initiation at a teaching hospital from July 1st, 2011 to October 31st, 2012. Results: Cinacalcet decreased iPTH by 19% from baseline after 4weeks treatment and it was statistically significant (p<0.001). Cinacalcet also significantly decreased iPTH levels regardless of dialysis modality (hemodialysis group versus peritoneal dialysis group) and severity of SHPT (iPTH 300-800 pg/ml group versus iPTH >800 pg/ml group). Serum calcium, phosphorus and Ca x P levels were decreased without statistical significance. Gastrointestinal events, headache and hypocalcemia were the most common side effects. Monitoring for iPTH and serum calcium was not performed appropriately. 43.7% patients initiated cinacalcet therapy at serum calcium level< 9.0 mg/dl. Conclusion: In conclusion, cinacalcet lowers parathyroid hormone levels with no serious side effects. However, it is required to avoid cinacalcet treatment in patients with low serum calcium levels and monitor iPTH and serum calcium levels during cinacalcet administration.

The Acute Intermittent Peritoneal Dialysis in Acute Renal Failure of Newborn and Young Infants (신생아와 유아의 급성신부전증에 실시한 급성복막투석)

  • Park, Yong-Hoon;Moon, Han-Ku
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.375-382
    • /
    • 1986
  • We studied the effects of the acute intermittent peritoneal dialysis in severe acute renal failure of 1 newborn infant and 2 young infants during 18 months period from February 1985 to April 1986. The predisposing illnesses were severe acute gastroenteritis with dehydration. Reye's syndrome, and bilateral nephrolithiasis with hyperuricemia. The concomittent illnesses were severe hypernatremia, hyponatremia, hyperkalemia, hypocalcemia, hypoglycemia, DIC(disseminated intravascular coagulopathy), paralytic ileus, metabolic acidosis and gastrointestinal bleeding. As a dialvsate, Imperinol $solution^R$, 1.5% was used in all cases. The cycles of dialysis were 8, 16, and 41 times in each cases. Observed complications during dialysis were leakage, and abdominal wall and scrotol swelling in 2 cases, hyperglycemia in 1 case, and peritonitis in 1 case. Acinetobacter calcoaceticus was cultured in peritoneal fluid of peritonitis. These complications were treated by stopping dialysis in leakage and abdiminal wall swelling, insulin therapy in hyperglycemia, and intraperitoneal and systemic antibiotics therapy in peritonitis. We experienced improvements of severe acute renal failure with variable concomittant illnesses by acute intermittent peritoneal dialysis despite of the treatable complications of dialysis in all cases.

  • PDF

Testosterone-encapsulated Surfactant-free Nanoparicles of Poly(DL-lactide-co-glycolide): Preparation and Release Behavior

  • Jeong, Young-Il;Shim, Yong-Ho;Song, Ki-Chan;Park, Youeng-Guen;Ryu, Hwa-Won;Nah, Jae-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1579-1584
    • /
    • 2002
  • Since surfactant or emulsifiers remained on the nanoparticle surface significantly affect the physicochemical properties, the biodegradation rate, the biodistribution, and the biocompatibility of nanoparticles, surfactant-free nanoparticles should be good candidate. surfactant-free PLGA nanoparticles were successfully prepared by both the dialysis method and the solvent diffusion method. The PLGA nanoparticles prepared using the solvent diffusion method has a smaller particle size than the dialysis method. The solvent diffusion method was better for a higher loading efficiency than the dialysis method but the nanoparticle yield was lower. Testosterone (TST) release from the PLGA nanoparticles was dependent on the particle size rather than the drug contents. Testosterone release from the PLGA nanoparticles prepared by the solvent diffusion method using acetone was faster than those prepared by the dialysis method. TST release from the PLGA nanoparticles prepared by the solvent diffusion method using acetone and the dialysis method using dimethylformamide (DMF) was completed for 4 days while the PLGA nanoparticles prepared by the dialysis method using acetone showed approximately 80% TST release after 4 days. Since the PLGA nanoparticle degradation ratio was below 20% within 5 days at all samples while TST release completed within 4 days, TST release was dependent on the diffusion mechanism rather than degradation.

Chronic Dialysis in Infants and Children Under 2 Years of Age (2세 미만 만성 신부전 환아에서의 만성 투석)

  • Sohn, Young-Bae;Nam, Sook-Hyun;Kwak, Min-Jung;Kim, Su-Jin;Jin, Dong-Kyu;Paik, Kyung-Hoon
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2007
  • Purpose : Dialysis in children with chronic renal failure presents with many difficulies. The purpose of this study is to find an improved method in chronic dialysis in infants and children less than 2 years of age by analyzing the experience with 10 cases. Methods : A retrospective review of the medical records of 10 patients(6 boys and 4 girls) was conducted. The patients had chronic renal failure and underwent chronic dialysis at Samsung medical center from March 1999 to February 2007. Results : At Initiation of dialysis, the median age was 3 months old(22 days-20 months), the median body weight was 3.75 kg(2.2-10.3 kg), and the median serum creatinine level was 4.3 mg/dL(2.0-11.4 mg/dL). The median duration of dialysis was 29.5 months(3-62 months). Dysplastic kidney disease was the most common underlying renal disease. Two patients were treated with hemodialysis, 4 patients with peritoneal dialysis, and 4 patients eventually switched dialysis modality. Nine of the 10 patients took erythropoietin and anti-hypertensive drugs. At the end of the follow up period, 1 patient received kidney transplantation, 2 patients died due to sepsis, and 5 patients were treated with peritoneal dialysis. Two patients were lost to follow up. The most common complication of dialysis was infection. Achieving vascular access and maintaining proper catheter function were the most important factors in treating patients with hemodialysis. The growth status of patients was aggravated after 6 month of dialysis but improved after 1 year of dialysis. Patients showed better growth on peritoneal dialysis than hemodialysis. Conclusion : Chronic dialysis can be performed successfully in infants and children under 2 years of age. Vascular access was the main limitation of hemodialysis, and infection was the common problem in both hemodialysis and peritoneal dialysis. To improve the patients survival rate and quality of life, major efforts should be directed toward the prevention of infection and preservation of catheter function. (J Korean Soc Pediatr Nephrol 2007;11:41-50)

  • PDF

A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅰ). Improvements of the Dialysis Apparatus and Its Operations (透膜法에 依한 이온量 및 分子量의 決定에 關한 硏究 (I) 透析裝置 및 實驗方法의 改良)

  • Shin Yun Kyong;Rhee Jhun
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.304-313
    • /
    • 1972
  • This paper reports the improvements of the dialysis apparatus and operations since there are some problems to be improved in the dialysis method which is applied to determine the ionic and molecular weight of dissolved particles. The hook gauge was utilized in order to control the surface level of the dialysing solution and the solvent to be equal with the precision of 0.02 mm to minimize the osmotic and filtration effects. An accurate agitation velocity for both solutions was maintained and so was the same temperature for both solutions with ${\pm}0.01^{\circ}C$ precision. The dialysis membrane was fixed uniformly and flatly on one end of the dialysis cylinder by using a newly developed ring. The volume change of the dialysing solution during the dialysis was reduced to the range of -1.62 ~ +0.92%. Optimum duration of dialysis was searched from the relation between the osmotic and filtration effect and the pore size of the membrane.

  • PDF

Comparison of Self-Esteem and Quality of Life in Patients on Hemodialysis and Peritoneal Dialysis (혈액투석환자와 복막투석환자의 자아존중감과 삶의 질 비교)

  • Chun, Chung Ja;Jung, Young Mi
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.706-716
    • /
    • 2000
  • The purpose of this study was to provide fundamental data for nursing intervention by assessing self-esteem and quality of life(QL) in patients on hemodialysis and peritoneal dialysis. The subjects of this study were 60 patients on hemodialysis at H university medical center in Seoul and 56 patients on peritoneal dialysis at B company. The analysis was done by using t-test, ANOVA, Scheffe and Stepwise multiple regression. The results were as follows: 1. The average self-esteem score was significantly higher in patients on hemodialysis (27.98) than in patients on peritoneal dialysis (25.64). And there were no statistically significant differences between patients on hemodialysis(128.45) and patients on peritoneal dialysis(122.83) in the scores on QL. Among four factors of QL, hemodiaysis patients showed higher score than peritoneal dialysis patients in all factors. But, only family had statiscally significant differences. Also family showed the highest score in both groups, but psychomental showed the lowest score. 2. In patients on hemodialysis, self-esteem was significantly different by occupation(t=3.122, p=.003) and in patients on peritoneal dialysis by age(F=4.450, p=.007), education level(F=7.458, p=.001) and occupation (t=2.491, p=.017). Also in patients on hemodialysis, QL was significantly different by occupation(t=2.223, p=.033) and in patients on peritoneal dialysis by education level(F=4.007, p=.024), and occupation (t=2.806, p=.007). 3. Self-esteem accounted for 36.3% of variance in QL and monthly income accounted for an additional 6.1% of QL in hemodialysis patients by means of stepwise multiple regression analysis. In peritoneal patients, self-esteem accounted for 65.1% and monthly income accounted for an additional 2.7% in QL.

  • PDF

A Study on the Space Composition for Department of Kidney Dialysis in Regional Public Hospital(1) (지역거점 공공병원의 인공신장부 공간구성에 관한 연구(1))

  • Chai, Choul Gyun;Park, Kyeong Hyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Purpose: This study presents the results of the analysis on space utilization of kidney dialysis units in regional public hospitals, which plays a key role in local public medical services. The result aims to achieve safety from infection, allow comfort for the dialysis environment, and stability for medical support. The purpose of this study is to present fundamental data for architectural plans for the kidney dialysis unit, as well as to alleviate potential infectious diseases such as COVID-19. Methods: For research purposes, the investigation and analysis of space utilization were based on architectural floor plans, research papers and literature, related legal systems, and public statistics. Of the main 35 regional public hospitals, in regards to data accessibility, 15 facilities were selected to conduct the survey and analysis for the objective. Results: The space composition by area research results of kidney dialysis units in public hospitals are as follows: Firstly, most targets do not have required rooms in the access and support area, except for the hemodialysis beds in the treatment section. Secondly, the access area requires necessary room and space design that took into consideration of convenience and accessibility for patients. Thirdly, in regards to infection prevention and control, proper circulation and room plan is essential for storage and disposal of contaminated products and linen after use. For the treatment area, the arrangement plan needs to establish a visual connection between the isolation room, the nursing station, and the bed area. Additionally, consideration of circulation in the preparation, treatment, observation, examination, and all other rooms in the facility is required. Lastly, for the support area, the room is designed to consider adequate working and meeting spaces for the medical staff, consultation space for patients or guardians, separate storage and disposal of clean and contaminated items, and the storage of various equipment for dialysis. Implications: In preparation for the increase in chronic kidney failure patients and the spread of infectious diseases, such as COVID-19, the researched data demonstrates the basic guidelines for space composition of kidney dialysis units and the significant role of regional public hospitals.

Study on Antibody-enzyme Coupling and Enzyme Immunoassay Methods (효소-항체의 결합 및 효소면역측정 방법의 연구)

  • Jang Sean Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.3
    • /
    • pp.874-879
    • /
    • 2004
  • Alakaline phosphatase (ALP)- or horseradish peroxidase (HRP)-antibody conjugate was used frequently on the immunological detection methods such as enzyme-linked immunosobent assay (ELISA), immunobolt, immunohistochemistry. The classical enzyme-antibody coupling method by one-step (direction) injection of glutaraldehyde bring into being disadvantage such as low sensitivity of antigen detection because of homopolymers. This study was modified with the dialysis glutaraldehyde method to provide simple coupling through E-amino residues present in most protein. The dialysis glutaraldehyde coupling effects were better than the classical one-step glutaraldehyde injection in antigen detection of ELISA and immunobolt. Optimal dose of the dialysis glutaraldehyde solution was 0.10-0.25 %. This results suggest that the dialysis glutaraldehyde coupling method can readily applied to antigen detection of in vitro and in vivo.

Renal replacement therapy in children with acute renal failure (소아 급성 신부전증의 신장 대체 요법)

  • Paik, Kyung Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.938-947
    • /
    • 2007
  • Many dialysis modalities such as peritoneal dialysis (PD), hemodialysis (HD) and continuous hemofiltration or hemodialysis (CRRT) are available for the management of pediatric patients with acute renal failure (ARF). PD is a relatively simple, inexpensive modality and can be used in hemodynamically unstable patients. But, it may not be the optimal therapy for patients with severe volume overload or life threatening hyperkalemia. HD is the preferred modality for the treatment of severe volume overload, severe hyperkalemia, but it needs vascular access. Improvements in the HD equipment have allowed HD to be performend in small children. Recents technological improvements in CRRT therapies have enabled pediatric patients who are less stable to be treated. CRRT is becoming the preferred method of acute therapy in pediatric intensive care units. A sound knowledge of the underlying principles of dialysis and awareness of recent technological advancements in differnet dialysis modalities will hopefully result in improved management of children with ARF.

A Case of Peritoneal Dialysis-related Peritonitis Caused by Aeromonas Hydrophila in the Patient Receiving Automated Peritoneal Dialysis

  • Kim, Hyun Jin;Park, Hyun Sun;Bae, Eunsin;Kim, Hae Won;Kim, Beom;Moon, Kyoung Hyoub;Lee, Dong-Young
    • Electrolytes & blood pressure
    • /
    • v.16 no.2
    • /
    • pp.27-29
    • /
    • 2018
  • Peritoneal dialysis (PD)-related peritonitis is a major cause of injury and technique failure in patients undergoing PD. Aeromonas hydrophila is ubiquitous in the environment, and is a Gram-negative rod associated with infections in fish and amphibians in most cases; however, it can also cause opportunistic infections in immunocompromised patients. We report a case of A. hydrophila peritonitis in a 56-year-old male on automated PD. Peritonitis may have been caused by contamination of the Set Plus, a component of the automated peritoneal dialysis device. Although Set Plus is disposable, the patient reused the product by cleansing with tap water. He was successfully treated with intraperitoneally-administered ceftazidime and has been well without recurrence for more than 2 years.