• Title/Summary/Keyword: diagonal reinforcement

Search Result 127, Processing Time 0.029 seconds

Diagonal Tension Failure Model for RC Slender Beams without Shear Reinforcement Based on Kinematical Conditions (II) - Verification

  • You, Young-Min;Kang, Won-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.16-25
    • /
    • 2007
  • In a companion paper, a rational mechanical model to predict the entire behavior of point-loaded RC slender beams (a/d > 2.5) without shear reinforcement was developed. This paper presents the test results of 9 slender shear beams and compares them with analytical results performed by the proposed model. They are grouped by two parameters, which are shear span ratio and concrete strength. Three kinds of concrete strength the 26.5, 39.2, and 58.8 MPa were included as a major experimental parameter together with different shear span ratios ranging from 3 to 6 depending on the test series. Tests were set up as a traditional 3 point bending test. Various measurements were taken to monitor abrupt shear failure. Test results were not only compared with analytical results from the proposed model, but also other formulas, to consider the various aspects of shear failure such as kinematical conditions or shear capacity. Finally, a review of the proposed model is presented with respect to the shear transfer mechanisms and the effect of test parameters. Results show that several assumptions and proposals adopted in the proposed model are rational and reasonable.

Failure Mode and Design Guideline for Reinforced Concrete Slab Strengthened Using Carbon FRP Grid (Carbon FRP Grid로 휨 보강한 철근콘크리트 슬래브의 파괴형태와 설계기준)

  • Park Sang-Yeol;Xian Cui
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.667-675
    • /
    • 2004
  • This paper presents the failure mode and strengthening design of reinforced concrete slab strengthened with Carbon Fiber Reinforced Polymer(CFRP) grid. Parameters involved in this experimental study are FRP grid reinforcement quantity, repair mortar thickness, the presence of anchor, and strengthening in compression. In this study, there are different failure types with increasing the CFRP grid strengthening reinforcement. On the low strengthening level, CFRP grid in repair mortar cover ruptures. On the moderate strengthening level, there is a debonding shear failure in the interface of carbon FRP grid because of the excessive shear deformation. On the high strengthening level, diagonal shear failure occurs. With the increasing of FRP grid reinforcement, the strengthening effect increased, but the ductility decreased. By limiting the strengthening level, it can be achieved to prevent shear failure which result in sudden loss in the resisting load capacity. CFRP rupture failure is desirable, because CFRP ruptured concrete slab keeps the same load capacity and ductility haying before strengthening even after failure. Finally, design guideline and procedure are given for strengthening of concrete slab with CFRP grid.

Ductility of carbon fiber-reinforced polymer (CFRP) strengthened reinforced concrete beams: Experimental investigation

  • Kim, Sang Hun;Aboutaha, Riyad S.
    • Steel and Composite Structures
    • /
    • v.4 no.5
    • /
    • pp.333-353
    • /
    • 2004
  • Strength of reinforced concrete beams can easily be increased by the use of externally bonded CFRP composites. However, the mode of failure of CFRP strengthened beam is usually brittle due to tension-shear failure in the concrete substrate or bond failure near the CFRP-Concrete interface. In order to improve the ductility of CFRP strengthened concrete beams, critical variables need to be investigated. This experimental and analytical research focused on a series of reinforced concrete beams strengthened with CFRP composites to enhance the flexural capacity and ductility. The main variables were the amount of CFRP composites, the amount of longitudinal and shear reinforcement, and the effect of CFRP end diagonal anchorage system. Sixteen full-scale beams were investigated. A new design guideline was proposed according to the effects of the above-mentioned variables. The experimental and analytical results were found to be in good agreement.

Size Effect on Shear Strength of Reinforced High Strength Concrete Beams (고강도 철근콘크리트 보의 전단강도에 관한 크기효과)

  • 김진근;박연동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.155-160
    • /
    • 1992
  • In this study , the size effect on diagonal shear failure of reinforced high strength concrete beams was investigated, For this purpose, ten singly reinforced high strength concrete beams without web reinforcement were tested for five different dimensions of effective depth which were varied from 67mm to 915mm. The compressive strength of concrete used in this study was 53.7 MPa. One type of reinforcing bar with nominal yield strength of 400 MPa was used. Test results were analyzed and compared with strength predicted by ACI code equation, Zutty's equation and Bazant &Kim's equation. As the results, ACI code equation was seriously unconservative for beams with d of 915mm. Bazant & Kim's equation predicted well the trend of test data. Within the scope of this study, there was no clear difference in size effect with variation of compressive strength of concrete.

  • PDF

An Experimental Study on the Shear behavior of High Strength light-aggregate Reinforced Concrete Beam (고강도 경량 콘크리트 보의 전단거동에 관한 실험적 연구)

  • 박완신;진인철;윤현도;정수영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.385-388
    • /
    • 1999
  • This study is to investigate experimentally the shear capacity of high-strength reinforced concrete beams subjected to monotonic loading. Nine reinforced concrete beams using high strength concrete $(f'c=380kg/\textrm{cm}^2)$ are tested to determine their diagonal cracking and ultimate shear capacity. The main variables are shear span-depth ratio a/d=1.5, 2.5, 3.5, and shear reinforcement ratio. All specimens are 170mm wide and have a total depth of 300mm. The test results indicate that ACI 318-95(b) Code for shear capacity gave closest agrement with the exsprimental results. The beams with a shear spear-depth ratio 1.5 and 2.5. ACI 318-95 Code underestimates shear strength carried by vertical shear reinforcements.

Strength Prediction of Corbels Using Strut-and-Tie Model Analysis

  • Kassem, Wael
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.2
    • /
    • pp.255-266
    • /
    • 2015
  • A strut-and-tie based method intended for determining the load-carrying capacity of reinforced concrete (RC) corbels is presented in this paper. In addition to the normal strut-and-tie force equilibrium requirements, the proposed model is based on secant stiffness formulation, incorporating strain compatibility and constitutive laws of cracked RC. The proposed method evaluates the load-carrying capacity as limited by the failure modes associated with nodal crushing, yielding of the longitudinal principal reinforcement, as well as crushing or splitting of the diagonal strut. Load-carrying capacity predictions obtained from the proposed analysis method are in a better agreement with corbel test results of a comprehensive database, comprising 455 test results, compiled from the available literature, than other existing models for corbels. This method is illustrated to provide more accurate estimates of behaviour and capacity than the shear-friction based approach implemented by the ACI 318-11, the strut-and-tie provisions in different codes (American, Australian, Canadian, Eurocode and New Zealand).

Membrane Structures - Their Characteristics and Various Applications -

  • Kawaguchi, Mamoru
    • Journal of Korean Association for Spatial Structures
    • /
    • v.1 no.2 s.2
    • /
    • pp.10-22
    • /
    • 2001
  • A few characteristics of membrane structures which the author thinks important for design are described on the basis of his experience in research and design of this kind of structures. Different in behaviors of air-supported and air-inflated structures are first explained for a better understanding of these structures. Attention is drawn to unfavorable behaviors of an air-beam when it is reinforced by diagonal members. The shallowest membrane structure which can be made as an airdome is pursued, and its application to a metal membrane dome is shown. Attempts which have been made by the author seeking for the possibility of membrane structures made of metal sheet, plastic film with and without reinforcement are described with realized examples. A 100m long jumbo carp is explained as an example of a flying membrane.

  • PDF

An Experimental Study on the Shear Resistance of Horizontal Shear Reinforcement in R.C. Deep Beams (철근콘크리트 깊은 보에서 수평 전단철근의 전단저항에 관한 실험적 연구)

  • 양근혁;이영호;은희창;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.903-906
    • /
    • 2001
  • The objective of this experimental study was to understand the effect of horizontal shear bar on the shear behavior of R.C. deep beams. Therefore, in the test program, the horizontal shear bar ratio($\rho_{sh}$) and shear span-to-overall depth ratio(a/h) are considered as two main variables. Test results indicate that for deep beams with a/h equal to 1.0, horizontal shear bar is less efficient in restricting the diagonal crack width development and enhancing the ultimate shear strength. So, it can be concluded that shear resistance of horizontal shear bar is related to a/h rather than clear span-to-effective depth ratio($l_{n}$/d) recommended in ACI code.

  • PDF

Shear Behavior of High Strength Concrete Beams Input Polymer-Steel Fibrous (폴리머-강섬유를 혼입한 고강도 콘크리트보의 전단거동)

  • Park, Jong-Gun;Lee, Sung-Woo;Kwak, Kae-Hwan
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.176-180
    • /
    • 2001
  • Steel fiber and polymer are used widely for reinforcement material of RC structures because of its excellences of the durability, serviceability as well as mechanical properties. The purpose of this study is investigate the shear behavior of high concrete beams input polymer-steel fibrous. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns and fracture modes. Also, load-strain and load-deflection examined, during the test cracks are sketched the load values according to grow of crack.

  • PDF

The Size Effect of the Shear Strengths of Reinforced Concrete Beams Strengthened with Carbon FRP (CFRP로 전단보강된 철근콘크리트 보의 크기효과)

  • Zi, Goang-Seup;Kim, Ki-Hong;Kim, Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.291-294
    • /
    • 2005
  • Presented are the results of recent tests on diagonal shear failure of reinforced concrete beams which are externally reinforced in the transverse direction by a unidirectional carbon fiber reinforced polymer, instead of the traditional steel stirrups. Three different series of the beams with different shear reinforcements, i.e. U-wrapping with carbon sheet, U-wrapping with carbon strips and full wrapping with carbon strips were tested. Those beams were geometrically similar, and the size range is 1:1.9:4. The failure of the beams are characterized by delamination, crushing of concrete and distributed shear cracks. It is found that the size effect is much weaker than that of the reference beams without CFRP. Therefore CFRP sheet may be used as the transverse reinforcement with a minor size effect. However, it is not clear that the same conclusion can be drawn in other sizes. Further researches are recommended.

  • PDF