• 제목/요약/키워드: diagonal crack

검색결과 99건 처리시간 0.021초

철근콘크리트 부재의 균열 후 강성 이론 (Theoretical Stiffness of Cracked Reinforced Concrete Elements)

  • 김장훈
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.79-88
    • /
    • 1999
  • The purpose of this paper is to develop a mathematical expression for computing crack angles based on reinforcement volumes in the longitudinal and transverse directions, member end-fixity and length-to-width aspect ratio. For this a reinforced concrete beam-column element is assumed to possess a series of potential crack planes represented by a number of differential truss elements. Depending on the boundary condition, a constant angle truss or a variable angle truss is employed to model the cracked structural concrete member. The truss models are then analyzed using the virtual work method of analysis to relate forces and deformations. Rigorous and simplified solution schemes are presented. An equation to estimate the theoretical crack angle is derived by considering the energy minimization on the virtual work done over both the shear and flexural components the energy minimization on the virtual work done over both the shear and flexural components of truss models. The crack angle in this study is defined as the steepest one among fan-shaped angles measured from the longitudinal axis of the member to the diagonal crack. The theoretical crack angle predictions are validated against experimentally observed crack angle reported by previous researchers in the literature. Good agreement between theory and experiment is obtained.

강섬유를 혼입한 2경간 연속보의 피로수명 예측에 관한 연구 (A Study on the Prediction Fatigue Life of Two-Span Beams with Steel Fibrous)

  • 곽계환;김원태;이진성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.375-382
    • /
    • 2001
  • This study is attempted to predict experimentally the fatigue crack propagation behavior of two-span beams with steel fibrous for various steel fibrous contents. The static tests and the fatigue tests were performed on a series of SFRC(steel fibrous reinforced concrete) to investigate the fatigue behavior of SFRC varying with the steel fibrous contents. Through this test, the diagonal cracking loads, ultimate loads, deflections, strains of concrete and steels. Fatigue crack length were measured by the eye-observation. As a result of test, A model for S-N relationship, and propagation life of fatigue crack of SFRC was proposed. The crack growth and failure of SFRC beams were studied.

  • PDF

고강도 콘크리트를 사용한 철근콘크리트 보의 전단피로거동에 관한 연구 (A Study on Shear-Fatigue Behavior of Reinforced Concrete Beams using High Strength Concrete)

  • 곽계환;박종건
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.119-130
    • /
    • 1999
  • Recently, as the building structure has been larger, higher, longer and more specialized, the demand of material with high-strength concrete for building has been increasing. In this research, silica-fume was used as an admixture in order to get a high-strength concrete. From the test result, High-strength concrete with cylinder strength of 1,200kgf/$\textrm{cm}^2$ in 28-days was produced and tested. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns and fracture modes. The load versus strain and load versus deflection relations were obtained from the static test. The relation of cycle loading to deflections on the mid-span, the crack propagation and the modes of failure according to cycle number, fatigue life and S-N curve were observed through the fatigue test. Based on the fatigue test results, high-strength reinforced concrete beams failed to 57~66 percent of the static ultimate strength. Fatigue strength about two million cycles from S-N curves was certified by 60 percent of static ultimate strength.

외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과 (Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

강섬유 혼입 폴리머 시멘트 고강도 콘크리트 보의 전단거동 (Shear Behavior of Polymer Cement High Strength Concrete Beams Mixed with Steel Fiber)

  • 곽계환;박종건;곽경헌
    • 한국농공학회지
    • /
    • 제44권1호
    • /
    • pp.93-102
    • /
    • 2002
  • Steel fiber and polymer are used widely for reinforcement material of RC structures because of its excellences of the durability, serviceability as well as mechanical properties. The purpose of this study is to investigate the shear behavior of polymer cement high strength concrete beams mixed with steel fiber. The compressive strength of concrete was based on the 100$\times$200 mm cylinder specimens. The compressive strength of concrete are 320$kgf/cm^2$, 436 $kgf/cm^2$ and 520 $kgf/cm^2$ in the 28 days. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns and fracture modes. Also, load-strain and load-deflection examined. During the test cracks were sketched against the load values according to the growth of crack. result are as follows; (1) The failure modes of the specimens are increased in rigidity and durability with mixing steel fiber and polymer. (2) The load of initial crack was similar a theory of shear-crack strength. (3) The deflection and strain at failure load of Polymer-steel fiber high strength concrete beams were increased, improving the brittleness of the high strength concrete.

Shear Deformation of Steel Fiber-Reinforced Prestressed Concrete Beams

  • Hwang, Jin-Ha;Lee, Deuck Hang;Ju, Hyunjin;Kim, Kang Su;Kang, Thomas H.K.;Pan, Zuanfeng
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권sup3호
    • /
    • pp.53-63
    • /
    • 2016
  • Steel fiber-reinforced prestressed concrete (SFRPSC) members typically have high shear strength and deformation capability, compared to conventional prestressed concrete (PSC) members, due to the resistance provided by steel fibers at the crack surface after the onset of diagonal cracking. In this study, shear tests were conducted on the SFRPSC members with the test variables of concrete compressive strength, fiber volume fraction, and prestressing force level. Their localized behavior around the critical shear cracks was measured by a non-contact image-based displacement measurement system, and thus their shear deformation was thoroughly investigated. The tested SFRPSC members showed higher shear strengths as the concrete compressive strength or the level of prestress increased, and their stiffnesses did not change significantly, even after diagonal cracking due to the resistance of steel fibers. As the level of prestress increased, the shear deformation was contributed by the crack opening displacement more than the slip displacement. In addition, the local displacements around the shear crack progressed toward directions that differ from those expected by the principal strain angles that can be typically obtained from the average strains of the concrete element. Thus, this localized deformation characteristics around the shear cracks should be considered when measuring the local deformation of concrete elements near discrete cracks or when calculating the local stresses.

휨 항복형 철근콘크리트 전단벽의 등가소성힌지길이 모델 (Equivalent Plastic Hinge Length Model for Flexure-Governed RC Shear Walls)

  • 문주현;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2014
  • 본 연구의 목적은 경계요소를 갖는 철근콘크리트 전단벽의 잠재소성힌지길이를 합리적으로 평가할 수 있는 단순모델의 제시이다. 전단벽의 높이에 따른 이상화된 곡률분포로부터, 기본방정식은 항복모멘트와 최대모멘트 그리고 사인장균열에 의한 부가모멘트의 함수로 일반화되었다. 전단벽의 항복모멘트와 최대모멘트는 변형률 적합조건과 힘의 평형조건을 기반하여 산정하였다. 사인장균열 발생의 여부는 ACI 318-11에서 제시된 콘크리트의 전단력으로부터 검토되었으며, 부가모멘트는 Park and Paulay에 의해 제시된 트러스기구를 이용하여 산정하였다. 이들 모멘트식들은 다양한 변수범위에서 변수연구를 수행하였다. 결과적으로 등가소성힌지길이는 주철근 및 수직철근지수와 축력지수의 함수로 제시될 수 있었다. 제시된 등가소성힌지길이의 모델은 실험결과의 비교에서 평균 및 표준편차가 각각 1.019와 0.102로 실험 결과를 정확하게 예측하였다.

Seismic behavior of interior RC beam-column joints with additional bars under cyclic loading

  • Lu, Xilin;Urukap, Tonny H.;Li, Sen;Lin, Fangshu
    • Earthquakes and Structures
    • /
    • 제3권1호
    • /
    • pp.37-57
    • /
    • 2012
  • The behavior of beam-column joints in moment resisting frame structures is susceptible to damage caused by seismic effects due to poor performance of the joints. A good number of researches were carried out to understand the complex mechanism of RC joints considered in current seismic design codes. The traditional construction detailing of transverse reinforcement has resulted in serious joint failures during earthquakes. This paper introduces a new design philosophy involving the use of additional diagonal bars within the joint particularly suitable for low to medium seismic effects in earthquake zones. In this study, ten full-scale interior beam-column specimens were constructed with various additional reinforcement details and configurations. The results of the experiment showed that adding additional bars is a promising approach in reinforced concrete structures where earthquakes are eminent. In terms of overall cracking observation during the test, the specimens with additional bars (diagonal and straight) compared with the ones without them showed fewer cracks in the column. Furthermore, concrete confinement is certainly an important design measure as recommended by most international codes.

현장타설 습식접합부가 있는 T형 PC 벽체의 내진성능 (Seismic Performance of T-Shaped PC Walls with Wet Cast Joint)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.255-266
    • /
    • 2014
  • 이 논문은 새로운 수직 접합부와 현장타설 습식 접합부를 가진 T형 프리캐스트 벽체의 내진 성능에 관한 연구이다. 반복하중을 받는 T형 PC 벽체의 하중-변위 관계, 강도, 연성도, 파괴 모드, 그리고 변형 능력에 대해 알아보았다. 실험체 주요 변수는 전단력 전달을 위한 대각 철근의 유무이다. 벽체의 양단에 위치한 길이방향 주철근이 먼저 항복을 하였고 최종 변형은 C형 접합부의 파괴에 의해 결정되었다. 그리고 전단력 전달을 위한 대각 철근은 균열 제어에 효과적인 것으로 나타났다. 단면 해석을 통해 구한 강도와 변형은 실험값과 대체로 일치하였다.

전단 보강이 없는 강섬유보강 고강도 철근 콘크리트보의 전단 거동에 관한 연구 (Shear Mechanism of Steel-Fiber Reinforced High Strength Concrete Beams without Sheat Confinement)

  • 오정근;이광수;신성우
    • 콘크리트학회지
    • /
    • 제3권3호
    • /
    • pp.141-148
    • /
    • 1991
  • 본 논문은 전단보강이 없는 강섬유보강 고강도 철근콘크리트보의 전단거동에 관한 연구로서 전단스팬비(a/b), 섬유첨가율(Vf)의 변화에 사인장균열 전단응력 및 극한전단응력의 변화를 관찰하였다. 실험결과 섬유첨가율이 증가할수록, 전단스팬비가 감소할수록 사인장균열 전단응력 및 극한전단응력이 증가함을 보여주고 있으며, 특히 섬유첨가율이 증가함에 따라 섬유의 균열억제거동에 의해 극한전단응력이 높게 증가함을 볼 수 있다. 본 연구에 의한 실험결과를 바탕으로 각 변수에 따른 사인장균열 전단응력 및 극한전단응력에 대한 실험식을 제안하였다.