• Title/Summary/Keyword: diagnostic software

Search Result 256, Processing Time 0.029 seconds

The On-Line Measuring of Dissipation Factor on pole Transformer (주상 변압기의 절연유 유전정접 활선 측정 기법)

  • Lee, Su-Kil;Kim, Jae-Chul;Yoon, Yong-Han;Lee, Bo-Hoo;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.853-855
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on the operating transformer by using digital signal processing. After applying voltage to the electrodes which is installed In a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques. we can check the dissipation factor of insulating oil. To Improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP (DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Yoon, Yong-Han;Rim, Sung-Jung;Kim, Oun-Seok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Development of Digital Endoscopic Data Management System (디지탈 내시경 데이터 management system의 개발)

  • Song, C.G.;Lee, S.M.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.304-306
    • /
    • 1996
  • Endoscopy has become a crucial diagnostic and theraputic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholesystectomy, peviscopic endometriosis, and surgical arthroscopy. In this study, we are developed computer system, which is composed of frame grabber, sound board, VCR control board, LAN card and EDMS(endoscopic data management software). Also, computer system has controled over peripheral instruments as a color video printer, video cassette recorder, and endoscopic input/output signals(image and doctor's speech). Also, we are developed one body system of camels control unit including an endoscopic miniature camera and light source. Our system offer unsurpassed image quality in terms of resolution and color fidelity. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both an image and drctor's speech synchronized with endoscopic image.

  • PDF

Electropulsegraph and Wave Classification Framework (Electropulsegraph 및 파형분류 프레임워크)

  • Park, JinSoo;Choi, Dong Hag;Min, Se Dong;Park, Doo-Soon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1388-1389
    • /
    • 2015
  • Electropulsegraphy is a medical device that was invented by an orient medical physician and a few engineers to help the physicians to diagnose patients in more systematic way by analyzing waveforms generated from the device. Data generated form the device has been collected for over several decades, and undergoes functional upgrades today. The device generates 33 waveforms that reflect the states of patients. As one of those upgrading efforts, we strive to develop an intelligent algorithm that makes the diagnostic process automatically, which was previously done manually for a long period of time. The logistic regression algorithm is used for our classification problems, which is one of those well-known algorithms for various classification problems such as character recognition systems. Out of the 33 waveforms, we only use 5 waveform data (Type1 toType5) as training data sets to estimate the parameters of the logistic regression. And the parameters are used to classify waveform inputs chosen at random.

Recent Advances in Examination of Vocal Fold Vibration (성대진동검사의 최신 지견)

  • Lee, Jin-Choon;Bae, Inho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • Human vocal cords vibrate as quickly as 100-250 times per second, so it is impossible to observe them with normal endoscopic diagnostic equipment. High-speed videolaryngoscopy (HSV) allows the visualization of non-periodic vibratory motion of vocal fold beyond the limitation of videostroboscopy. New developed post-processing methods that converts HSV to two-dimensional videokymography (2D VKG) using U-medical image-processing software can provide quantitative information on vocal fold mucosa vibration. Multifunctional laryngeal examination system is composed of 3 kinds of examinations such as HSV, 2D scanning digital kymography (2D DKG) and line scanning digital kymography (DKG). Evaluation of entire vocal cord vibratory pattern in each cord is possible using 2D DKG and a faster and more reliable quantitative information can be obtained. As this system is used in clinical and research, it is expected to bring much advances to the diagnosis of voice disorders. In this review, I will introduce the principles and advantages on examination of the vocal fold vibration, which is in the spotlight recently, and proceed with the literature review.

Erythrocyte Sedimentation Rate: Its Determinants and Relationship with Risk Factors Involved in Ischemic Stroke

  • Kaur, Kirandeep;Kaur, Amandeep;Kaur, Anupam
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Erythrocyte sedimentation rate (ESR) evaluation is a useful tool for monitoring disease activity in various inflammatory and non-inflammatory conditions. ESR is known to be influenced by a multitude of confounding factors. The present study aimed to assess the possible determinants of the ESR and its relationship with various risk factors involved in ischemic stroke. ESR and other hematological and biochemical parameters were investigated in 163 ischemic stroke patients (107 males and 56 females) selected based on imaging techniques including magnetic resonance imaging (MRI) or computed tomography (CT) scans. Statistical analysis was performed using the SPSS 16.0 software. Linear regression analysis showed a significant inverse relationship of hemoglobin (Hb) and hematocrit or packed cell volume (PCV) (P<0.001 for females; P<0.01 for males) with the ESR. It was observed that the red blood cell (RBC) count was not strongly correlated with the ESR (P<0.05 for both males and females). It was also observed that sex significantly affected the variables determining the ESR levels, whereas age had no effect. Gender differences were also observed with respect to Hb, RBC, PCV, mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), and ESR. The possible determinants of higher ESR levels in ischemic stroke may be sex, Hb, hematocrit, and RBC count, but the role of other clinical and laboratory parameters cannot be underestimated.

Comparison of mastoid air cell volume in patients with or without a pneumatized articular tubercle

  • Adisen, Mehmet Zahit;Aydogdu, Merve
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose: The aim of this study was to compare mastoid air cell volumes in patients with or without a pneumatized articular tubercle (PAT) on cone-beam computed tomography (CBCT) images. Materials and Methods: The CBCT images of 224 patients were retrospectively analyzed for the presence of PAT. The Digital Imaging and Communications in Medicine data of 30 patients with PAT and 30 individuals without PAT were transferred to 3D Doctor Software. Mastoid air cell volumes were measured using semi-automatic segmentation on axial sections. Data were analyzed using SPSS version 20.0. Results: The patients with PAT and those without PAT had a mean mastoid volume of 6.31±2.86 cm3 and 3.25±1.99 cm3, respectively. There were statistically significant differences in mastoid air cell volumes between patients with and without PAT regardless of sex and mastoid air cell side (P<0.05). Conclusion: The detection of PAT on routine dental radiographic examinations might be a potential prognostic factor that could be used to detect extensive pneumatization in the temporal bone. Clinicians should be aware that there may be widespread pneumatization of mastoid air cells in patients in whom PAT is detected. Advanced imaging should be performed in these cases, and possible complications due to surgical interventions should be considered.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Early Detection Assistance System for Rare Diseases based on Patient's Symptom Information (환자 증상정보 기반 희귀질환 조기 발견 보조시스템)

  • Jae-Min Choi;Sun-Yong Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.373-378
    • /
    • 2023
  • Untypical symptoms and lack of diagnostic records make it difficult for even medical specialists to detect rare diseases. Thus, it takes a lot of time and money from the onset of symptoms to an accurate diagnosis, which seriously results in physical, mental, and economic pressure on patients. In this paper, we propose and implement an early detection assistance system for rare diseases using web crawling and text mining, which can suggest the names of suspected rare diseases so that medical staffs can easily recall the disease names and make a final diagnosis of the rare diseases.