• Title/Summary/Keyword: diagnostic software

Search Result 253, Processing Time 0.024 seconds

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Study Focused on Task Process regarding Effective Information Transfer of Ancillary Tests in Diagnostic Pathology (병리추가조직검사 정보전달을 위한 업무프로세스 연구)

  • Ko, Jae-Nam;Park, Yun-Ik;Jung, Jin-Gyeong;Ahn, Sang-Ho;Kim, Jae-Ho;Shin, Hwa-Jeong;Hyun, Ji-Suk;Kim, Kyeong-Ho
    • Quality Improvement in Health Care
    • /
    • v.22 no.2
    • /
    • pp.95-108
    • /
    • 2016
  • Purpose: Ancillary tests such as immunohistochemistry or molecular testing for pathologic diagnosis are performed using ready-made tissue blocks for a histological examination. Various methods and processes during ancillary testing cause some of issues, particularly in the time required and the results reporting scheme. Methods: To solve these issues, we constructed real-time management software. When a pathologist or a clinician had ancillary tests examined using this software by selecting the codes of the needed ancillary tests on site and the system assigned the tests to each laboratory. Then, pathology technologists checked the referred tests and performed the examination. In clinical departments, serial number of each ancillary test can be matched the original pathologic ID. In the department of pathology, numbers of tissue blocks that needed additional tests could be indicated and detected using one-click detection system when a clinician referred the test. Results: Using this system resulted in simplifying the referral procedures from nine-steps to three-steps in each clinical department and from seven-steps to two-steps in department of pathology. Errors that happened on the paper-based request system were also reduced. Furthermore, the time required was saved by seven hours in pathologic laboratory on average. Mean durations from requesting to reporting of the ancillary test was reduced by three days for specimens of health promotion center. Conclusion: Construction of an effective information transfer system may be helpful for shortening the time required, reducing errors, and checking processing information of the tests in real time.

Artifacts in Digital Radiography (디지털 방사선 시스템에서 발생하는 Artifact)

  • Min, Jung-Whan;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.375-381
    • /
    • 2015
  • Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient's health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user didn't have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

EVALUATION OF INTERNAL DERANGEMENT OF TMJ BY ANALYZING TMJ SOUNDS (측두하악관절잡음을 이용한 악관절내장증 진단)

  • Kim, Tae-Woo;Yang, Won-Sik;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.423-439
    • /
    • 1996
  • The purpose of this study was to evaluate the diagnostic value of $SONOPAK^*$ in internal derangement of TMJ by comparing the spectral analysis data of TMJ sounds recorded by SONOPAK with the results of MRI. From the patients who came to Department of Orthodontics, Seoul National University Dental Hospital for treatment of malocclusion, eighteen adult patients (five males and thirteen females) with TMD symptoms were selected. After joint sounds were checked by a pediatric stethoscope, they were recorded and analyzed by the SONOPAK. The spectral analysis of the SONOPAK provided SONOPAK INTERPRETATION data about the stage of internal derangement, which were compared with the results of MRI. Among the patients whose disc positions were diagnosed as 'normar by MRI, there were no false positive diagnosis by the SONOPAK INTERPRETATION, But in the cases of anterior disc displacements (reducible and/or nonreducible), most of SONOPAK INTERPRETATION data did not coincide with MRI results. In conclusion, it is not adequate to try to differentiate reducible and non-reducible anterior disc displacements on the basis of joint sounds. And it is recommended not to determine the stage of internal derangement according to the nature of sounds. We suggest that the diagnostic value of the SONOPAK will be enhanced when clinicians combine some other informations such as clinical signs/symptoms and other supplementary diagnostic tools), and that more data be incoporated into the SONOPAK INTERPRETATION software.

  • PDF

Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine for Breast MRI Screening: a Meta-analysis

  • Yang, Xiao-Ping;Han, Yue-Dong;Ye, Jian-Jun;Chen, Gang;Luo, Ying;Ma, Hong-Xia;Yu, Xue-Wen;Niu, Juan-Qin;Ren, Fang-Yuan;Guo, You-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.5089-5095
    • /
    • 2014
  • Background: As a common and essential contrast medium at present, gadobenate dimeglumine has shown better performance than some other agents when applied to Breast Magnetic Resonance Imaging Screening (Breast MRI Screening). Nevertheless, reports on the diagnostic performance of these two mediums (gadobenate dimeglumine and gadopentetate dimeglumine) are not completely consistent. Objective: To assess the diagnostic value of gadobenate dimeglumine and gadopentetate dimeglumine for Breast MRI Screening in patients suffering from breast cancer and to provide more convinced evidence to guide clinical practice in terms of appropriate contrast agents. Data Sources and Review Methods: Original articles in English and Chinese published before January 2013 were selected from available databases (The Cochrane Library, PUBMED, EMBASE, Chinese Biomedical Literature Database, Chinese Scientific Journals Full-text Database, Chinese Journal Full-text). The criteria for inclusion and exclusion were based on the standard for diagnosis tests. Meta-Disc software (Version 1.4) was used for data analysis. Then, the area under curve (AUC) of SROC and the spearman rank correlation of sensitivity against (1-specificity) were calculated. Results: Total of 17 researches involving 1934 patients were included. The pooled sensitivity of gadobenate dimeglumine and gadopentetate dimeglumine were 0.99 (0.97, 1.00) and 0.93 (0.88, 1.00) respectively. The pooled specificity for these two contrast agents were 0.924 (0.902, 0.943) and 0.838 (0.817, 0.858) respectively, and the AUC of SROC curve were 0.9781 and 0.9215 respectively. Conclusions: Gadobenate dimeglumine can be regarded as a more effective and feasible contrast medium for Breast MRI Screening. At least 5% differences in diagnostic performance are usually considered as clinically relevant.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

Software Development for the Visualization of the Orientation of Brain Fiber Tracts in Diffusion Tensor Imaging Using a 24 bit Color Coding

  • Jung-Su Oh;In Chan Song;Ik-Hwan Cho;Jong-Hyo Kim;Kee Hyun Chang;Kwang-Suk Park
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.43-47
    • /
    • 2004
  • Interests in human brain functionality and its connectivity have much frown up. DTI (Diffusion tensor imaging) has been known as a non-invasive MR) technique capable of providing information on water diffusion in tissues and the organization of white matter tract. Thus. It can provide us the information on the direction of brain fiber tract and the connectivity among many important cortical regions which can not be examined by other anatomical or functional MRI techniques. In this study. was used the 24 bit color coding scheme on the IDL platform in the windows environment to visualize the orientation of major fiber tracts of brain such as main association, projection, commissural fibers and corticospinal tracts. We additionally implemented a color coding scheme for each directional component and FA (fractional anisotropy), and used various color tables for them to be visualized more definitely. Consequently we implemented a fancy and basic technique to visualize the directional information of fiber tracts efficiently and we confirmed the feasibility of the 24 bit color coding scheme in DTI by visualizing main fiber tracts.

Implementation and Design of motorcar consumption management iOS based software with OBD-II and WiFi network (OBD-II WiFi를 이용한 iOS 기반의 자동차 소모품관리 소프트웨어 설계 및 구현)

  • Jeong, Da-Woon;Nam, Jae-Hyun;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.475-478
    • /
    • 2011
  • driver for safety always check the status of their vehicle, and it is essential to understand. But if you want to know the status of the driver of the vehicle in specialist referral time and money because it costs the operator shall be paid. Today's rapidly changing IT technology with the development of the various features of your phone to check the status of the vehicle was able to do. However, the car's existing phone system, car diagnostic expertise must be learned because it will reveal the status of the vehicle do not have the expertise to not highlight the need for diagnostic. To reflect these points in smartphone users to easily use their own vehicles at a time to determine the status of a system that is required. In this paper, OBD-II protocol conversion WiFi OBD-II connector, retrieving information from the driver of the vehicle replacement cycle of consumables required vehicle inspection, vehicle problems in real-time diagnostic information to the user ease of use shows the IOS implementation in the automotive supply was implemented based on the smartphone.

  • PDF

Full mouth rehabilitation using various digital tools in a patient with collapsed bite due to severe attrition (심한 마모로 인하여 교합이 붕괴된 환자의 다양한 디지털 도구를 이용한 완전 구강회복증례)

  • Moon, Sooin;Lee, Younghoo;Hong, Seoung-Jin;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.320-329
    • /
    • 2022
  • Physiological wear of occlusal surface is inevitable throughout the lifetime, and considered to be normal. Pathologic wear, however, may cause fatal damage to the occlusal surface and destroy esthetics and proper anterior guidance. In such cases, rehabilitation of occlusal wear should be followed by thorough evaluation and diagnosis. In this present case, severe occlusal wear was found in the labial surfaces of mandibular anterior teeth and palatal surfaces of maxillary anterior teeth. Occlusal vertical dimension was evaluated and decided to be regained due to insufficient amount of restorative space. After determining new occlusal vertical dimension, diagnostic wax-up is usually performed to continue prosthodontic treatment. In this case with collapsed occlusion and loss of occlusal vertical dimension, conventional diagnostic wax-up was replaced with various digital devices. Diagnostic wax-up was digitally performed in the software and provisional prosthesis was fabricated with digital tools. With verification with provisional prosthesis, the entire dentition was rehabilitated with newly set occlusal vertical dimension and proper anterior guidance.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.