• 제목/요약/키워드: diagnostic sensitivity

검색결과 1,256건 처리시간 0.036초

Diagnostic performance of enzyme-linked immnosorbent assays for diagnosing paratuberculosis in cattle: a meta-analysis

  • Pak, Son-Il
    • 대한수의학회지
    • /
    • 제44권4호
    • /
    • pp.669-676
    • /
    • 2004
  • To evaluate the diagnostic accuracy of two commercial ELISA tests (Allied- and CSL-ELISA) for the diagnosis of Mycobacterium paratuberculosis in cattle, Meta-analysis using English language papers published during 1990-2001 was performed. Diagnostic odds ratios (DOR) were analyzed using regression analysis together with summary receiver operating characteristic (ROC) curves. The difference in diagnostic performance between the two ELISA systems was evaluated by using linear regression. Publication bias was assessed by funnel plot and linear regression. The pooled sensitivity and specificity were 44% (95% CI, 38 to 51) and 98% (95% CI, 96 to 99) for the random-effect model. The DOR between studies was heterogeneous. The area under the fitted ROC curve (AUC) was 0.72 for the unweighted and 0.77 for the weighted model. Maximum joint sensitivity and specificity for the unweighted and weighted model from their summary ROC curve were 70% and 75%, respectively. Based on the fitted model, at a specificity of 95%, sensitivity was estimated to be 52% for the unweighted and 57% for the weighted model. From the final multivariable model study characteristic, the country was the only significant variable with an explained component variance of 13.3%. There were no significant differences in discriminatory power, sensitivity, and specificity between the two ELISA tests. The overall diagnostic accuracy of two commercial ELISA tests was moderate, as judged by the AUC, maximum joint sensitivity and specificity, and estimates from the fitted model and clinical usefulness of the tests for screening program is limited because of low sensitivity and heterogeneous of DOR. It is, therefore, recommended to use ELISA tests as a parallel testing with other diagnostic tests together to increase test sensitivity in the screening program.

코로나19 신속진단검사는 얼마나 정확한가? (How accurate are rapid diagnostic tests for covid-19?)

  • 여인권
    • 응용통계연구
    • /
    • 제35권3호
    • /
    • pp.435-443
    • /
    • 2022
  • 이 논문에서는 질병관리청에서 제공한 코로나 진단검사 관련 자료를 이용하여 신속진단키트의 민감도 및 특이도에 따른 확진 비율과 신속검사에서 음성이 나왔을 때 실제로는 확진이었을 확률에 대해 알아본다. 또한 양성 반응 중 실제 확진의 확률을 알 때 민감도와 특이도 간의 관계를 유도하고 이를 통해 질병관리청의 자료에 따른 신속진단키트의 실제 민감도가 얼마나 되는지 알아 본다.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • 제29권6호
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교 (Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening)

  • 현영민;이삼선;최순철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

체강삼출액의 진단에 있어서 p53 단백의 유용성 (Diagnostic Value of p53 Expression in the Evaluation of Effusions)

  • 이지신;박창수
    • 대한세포병리학회지
    • /
    • 제7권2호
    • /
    • pp.138-143
    • /
    • 1996
  • The diagnostic accuracy of routine cytological preparations from effusions ranges from 60% to 70%. Immunohistochemical markers, especially tumor-associated antigens, have been successfully employed to increase diagnostic sensitivity in effusion cytology. However, more than two different antibodies in diagnosis of effusions are needed. In the view of prevalence of abnormalities of p53 gene in human malignancies we investigated the diagnostic usefulness of demonstration of p53 protein immunoreactivity in distinguishing benign changes versus malignant processes in effusions. p53 protein expression was studied immunohistochemically in 76 effusions(28 malignant and 48 benign) using anti-human p53 antibody p53 immunoreactivity was identified in 19 of 28(67.9%) malignant effusions. In contrast, no p53 immunoreactivity was observed in all benign effusions. A specificity of 100% and a sensitivity of 67.9% were observed. These results suggest that immunohistochemical detection of p53 protein seems to be helpful in distinguishing benign changes versus malignant processes in effusions, although its principal limitation is its relatively low sensitivity.

  • PDF

유압실린더 힘 제어계의 인-프로세스 서보밸브 마모진단에 관한 연구 (In-Process Diagnosis of Servovalve wear in Hydraulic Force Control Systems)

  • 김성동;전세형;장영배
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.22-30
    • /
    • 2009
  • An in-process method of diagnosing the spool wear of hydraulic servovalves was explored. The diagnostic method discussed in this paper is for force-control hydraulic servo systems. The key principle used is that pressure sensitivity of a servovalve drops as the valve spool wears out so that it is possible to determine the spool condition by monitoring pressure sensitivity. A diagnostic algorithm was developed and evaluated through numerical simulation and experiments. Two major steps of diagnosis are the evaluation of null bias of the servovalve and the approximation of pressure sensitivity, both of which could be successfully done during normal operation of a servo system. The difference between a new servovalve and a worn valve could be clearly detected in-process, and the diagnostic test was found to be repeatable.

  • PDF

Use of Likelihood Ratios in Evidence-based Clinical Decision Making

  • Kim, Eu-Tteum;Pak, Son-Il
    • 한국임상수의학회지
    • /
    • 제25권3호
    • /
    • pp.146-151
    • /
    • 2008
  • During the clinical decision making practitioners are often faced with performing diagnostic tests to solve the presenting problems seen in the patients. The diagnostic utility of a test has traditionally been described by technical terms such as sensitivity, specificity, and positive (PPV) and negative predictive value (NPV). Although well known, clinicians are frequently unclear about the concept and application of these terms in everyday evidence-based clinical decision making. Sensitivity and specificity, which are intrinsic properties of diagnostic tests, summarizes the characteristics of the test over a population. The PPV and NPV are greatly dependent on the population prevalence of disease, and thus they do not transferable to different patients or clinical settings. Besides, considering the fact that clinicians more often interested in knowing the extent to which a test result could confirm or exclude of a condition under consideration (posttest probability), these measures do not provide answers on this question. The likelihood ratios (LR) using the information contained in sensitivity and specificity are becoming increasingly popular for reporting the usefulness of diagnostic tests because this term provide an indication of posttest probability as a function of the pretest probability. In this article, clinical applications of LR are illustrated with some practical examples. Discussion is also included of the inherent limitations regarding diagnostic test characteristics.

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • 제62권6호
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

림프절 세침흡인 세포검사의 진단적 유용성과 한계 - 생검으로 확진한 176 예의 분석 - (Diagnostic Usefulness and Limitation of Fine Needle Aspiration Cytology of Lymph Node - Analysis of 176 Cases Confirmed by Biopsy -)

  • 김희성;김대수;오영륜;고영혜;이회정
    • 대한세포병리학회지
    • /
    • 제10권1호
    • /
    • pp.35-42
    • /
    • 1999
  • The accuracy of fine needle aspiration cytology(FNAC) of the lymph node was investigated through a review of 176 FNAC cases and the corresponding biopsies. We chose 157 FNAC cases after the exclusion of 19 inadequate ones. Sensitivity of malignancy was 94.0%, specificity 100%, false negativity 6.0%, and false positivity 0.0%. The overall diagnostic accuracy was 96.8%. Sensitivity of metastatic carcinoma was 98.0% and that of malignant lymphoma was 87.9%. False negative cases included one metastatic carcinoma and four malignant lymphomas. The aspirates of metastatic carcinoma with false negativity exhibited a diffuse smear of keratin debris without viable cells, which led to the difficulty in differentiation from benign epithelial cyst. The cases of malignant lymphoma with false negative diagnosis were two Hodgkin diseases, one Lennert's lymphoma, and one peripheral T cell lymphoma in the histologic sections. On the analysis of 39 cases of tuberculosis, 17 cases(43.6%) were diagnosed as tuberculosis, 4(10.3%) as granulomatous lymphadenitis, 3(7.7%) as necrotizing lymphadenitis, and 15(38.5%) as reactive hyperplasia or pyogenic inflammation. Sensitivity of tuberculosis was 53.9%. In conclusion, lymph node FNAC is an excellent non-invasive diagnostic tool for the diagnosis of metastatic carcinoma. The diagnostic accuracy of malignant lymphoma could be improved with flow cytometry or polymerase chain reaction for antigen receptor genes. For the FNAC diagnosis of tuberculosis, AFB stain, culture, and PCR would be helpful as adjuvant techniques.

  • PDF

Screening Sarcopenia in Rural Community-Dwelling Older Adults in Korea

  • KIM, Mi-Kyoung;LEE, Ji-Yeon;GIL, Cho-Rong;KIM, Bo-Ram;CHANG, Hee-Kyung
    • International Journal of Advanced Culture Technology
    • /
    • 제8권4호
    • /
    • pp.64-76
    • /
    • 2020
  • Purpose: Several screening tools have been developed to identify sarcopenia in rural community-dwelling older adults. We aimed to compare the diagnostic accuracy of two such tools, namely the SARC-F and SARC-CalF assessments. Methods: This cross-sectional study on 388 community-dwelling older adults comprised 254 women and 134 men with a mean age of 77.8 ± 6.26 year in Korea. We assessed muscle mass, muscle strength, and physical performance using a bioimpedance analysis device, hydraulic hand dynamometer, and 4 m gait speed test, respectively. Three widely-used diagnostic criteria [the Asian Working Group for Sarcopenia (AWGS), European Working Group on Sarcopenia in Older People, and the International Working Group on Sarcopenia] were applied. Sensitivity and specificity analyses were performed on the SARC-CalF and SARC-F tests. We used receiver-operating characteristic curves and the area under the curves (AUCs) to compare the diagnostic accuracy of the assessments with regard to sarcopenia. Results: An analysis using four sets of diagnostic criteria showed that the prevalence of sarcopenia was 27.6% to 41.0%. Using the AWGS 2019 criteria as a reference standard, the SARC-CalF had a sensitivity of 83.02% and a specificity of 53.71% in the entire study population, whereas the SARC-F had a sensitivity of 79.87% and a specificity of 41.92%. The AUCs for the SARC-CalF and SARC-F tests were 0.725 (95% confidence interval 0.678-0.769) and 0.645 (95% confidence interval 0.595-0.693), respectively (p<001). In the analyses using the other three diagnostic criteria, similarity was also confirmed. Conclusion: SARC-CalF showed better sensitivity than did SARC-F when diagnosing sarcopenia in rural community-dwelling older adults. Further studies are needed to verify this finding in different populations.