• Title/Summary/Keyword: diagnostic scale

Search Result 638, Processing Time 0.026 seconds

A Systematic Review of Validation Studies on Depression Rating Scales in Korea, with a Focus on Diagnostic Validity Information : Preliminary Study for Development of Korean Screening Tool for Depression (국내 우울증 평가도구 타당화 연구의 체계적 고찰-진단적 타당성을 중점으로 : 한국형 우울 선별 도구 개발을 위한 예비 연구)

  • Jung, Sooyun;Kim, Shin-Hyang;Park, Kiho;Jaekal, Eunju;Lee, Won-Hye;Choi, Younyoung;Lee, Seung-Hwan;Choi, Kee-Hong
    • Anxiety and mood
    • /
    • v.13 no.2
    • /
    • pp.53-59
    • /
    • 2017
  • Reliable and valid diagnostic screening tools in the primary care setting enable accurate estimation of depression in individuals at risk or in need of treatment, and provide patients with an opportunity to receive optimal treatments. Although there have been extensive studies on screening tools for depression used in domestic mental health settings, there is little consideration and lack of a thorough review of the diagnostic validity of screening tools. In the current review, we selected 13 representative screening tools for depression which were evaluated in a total of 19 validation studies conducted in Korea. We summarized DSM-5 target domains, diagnostic indices, sensitivity, specificity, cut-off scores, and diagnostic validity information for each tool. Finally, the depression measurement expert group was constituted to evaluate the current status of screening tools for depression, and their recommendations for a new screening tool were summarized. This study was conducted as part of the Mental Health Technology Development project to develop the Korean screening tool for depression (K-DEP).

Performance Simulation of a Gasoline Engine Using Multi-Length-Scale Production Rate Model (다중 길이척도 난류운동에너지 생성율 모형을 이용한 가솔린 기관의 성능 시뮬레이션)

  • 이홍국;최영돈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.1-14
    • /
    • 1999
  • In the present study, the flame factor which primarily influence the simulation accuracy of the combustion process in a gasoline engine was modeled as a nonlinear function of turbulent intensity to laminar flame speed ratio. Multi-length-scale production rate model for turbulent kinetic energy equation was introduced to consider the different length scales of the swirling and tumbling motions in cylinder on the production rte of turbulent kinetic energy. By7 introducing the multi-length-scale production rate model for the turbulent kinetic energy equation, the predictions of turbulent burning velocity , cylinder pressure, mass burning rate and engine performance of a gasoline engine can much be improved.

  • PDF

The Effect of Graston Technique and Chuna manual therapy combined with Korean Medical Treatment for fibromyalgia: A Case Report

  • Kim, Myung Kwan;Kim, Hyun Ji;Kim, Hye Su;Jeong, Jeong Gyo;Jeon, Ju Hyun
    • Journal of Acupuncture Research
    • /
    • v.34 no.3
    • /
    • pp.121-130
    • /
    • 2017
  • Objectives : The purpose of this study was to report the clinical effects of the Graston Technique and Chuna manual therapy, combined with Korean Medical Treatment for fibromyalgia. Methods : We treated a patient diagnosed with fibromyalgia. We used acupuncture, the Graston Technique, Chuna manual therapy, pharmacopuncture, herbal medicine, moxibustion and physical therapy. Outcomes were evaluated using the American College of Rheumatology Preliminary Diagnostic Criteria (ACR), the Fibromyalgia Impact Questionnaire (FIQ), and the Numeric Rating Scale (NRS). Results : The widespread pain index (WPI) scale score of the ACR decreased from 12 to 9, and the symptom severity scale (SS) score of the ACR decreased from 8 to 6. The FIQ score decreased from 63.69 to 50.15. On the NRS, lower back pain & lower limb pain decreased from 6 to 2; neck pain from 6 to 3; muscle tenderness & morning stiffness from 6 to 4; fatigue from 6 to 3; urticaria from 6 to 2. Conclusion : This case study suggests that the Graston Technique and Chuna manual therapy combined with Korean Medical Treatment may be effective treatments for fibromyalgia. However, further studies are needed.

A Validation Study of the Questionnaire of Sasang Constitution Classification(QSCC) (사상체질분류검사(四象體質分類檢査)(QSCC)의 타당화연구(妥當化硏究))

  • Kim, Sun Ho;Ko, Byung-Hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.5 no.1
    • /
    • pp.67-85
    • /
    • 1993
  • The Purpose of this study was to evaluate the reliability and the validation of four scales of Questionnaire for Sasang Constitution Classification (QSCC), newly constructed through statistical item analysis and to examine their diagnostic discrimination power. QSCC was administered to 105 inpatient at Kyung-Hee Oriental Medicine Hospital and local oriental clinics and 136 undergraduated students. 2 weeks later, QSCC was readministered to 220 same subjects. Data were collected during about 2 months from february to Apr. 20, 1992. For the purposes of this study, the collected data were analyzed by internal consistancy, test-retest reliability, ANOVA, Pearson correlation and discrimination analysis of spss pc+ v3.0 program. The results were as follows: 1. The reliability of four scales of QSCC was relatively favorable. The internal consistancy and test-retest reliability of Tae-Yaung-In(太陽人) scale were respectively Cronbach's ${\alpha}=0.9$ and r=0.89. Those of So-Yaung-In(少陽人) scale were respectively ${\alpha}=0.81$ and r=0.93. Those of Tae-Em-In(太陰人) scale were respectively ${\alpha}=0.72$ and r=0.74. Those of So-Em-In(少陰人) scale were respectively ${\alpha}=0.81$ and r=0.93. 2. The diagnostic discrimination abilities(Hit-ratio=56%)of QSCC were found to have more about 20% improvement than propotional chance criteria(37%). Especially, Hit-ratios for So-Yaung-In(63%) and Tae-Em-In(60%) were more high than that for So-Em-In(48%) 3. For male subjects, the construct validity of QSCC was founded to be relatively favorable. But that of QSCC for females was poor.

  • PDF

Clinical Utility and Cut-Off Scores of the Korean Adult Attention-Deficit/Hyperactivity Disorder Rating Scale

  • Hong, Minha;Lee, Young Sik;Kim, Bongseog;Joung, Yoo Sook;Yoo, Hanik K;Kim, Eui-Jung;Lee, Soyoung Irene;Bhang, Soo Young;Lee, Seung Yup;Han, Doughyun;Bahn, Geon Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.30 no.3
    • /
    • pp.116-120
    • /
    • 2019
  • Objectives: This study was conducted to re-validate the clinical efficacy of the Korean Adult Attention-Deficit/Hyperactivity Disorder (ADHD) Rating Scale (K-AARS), which is a self-report scale for ADHD in adults, and to determine the clinical utility and cut-off scores of K-AARS. Methods: The participants were 135 drug naïve adults with ADHD and 144 healthy controls. To diagnose ADHD based on the diagnostic criteria of the Diagnostic and Statistical Manual of Mental Disorders, 5th Edition, two board-certified pediatric psychiatrists interviewed the participants and completed the Mini International Neuropsychiatric Interview. K-AARS was applied to all participants. K-AARS comprises six clinical subscales, one impairment subscale, and one driving behavior subscale. The receiver operating characteristic analysis was conducted to calculate the cut-off scores of K-AARS. Results: All subscale scores, including six clinical subscale, impairment subscale, and driving behavior subscale scores, were found to be significant in distinguishing adults with ADHD from healthy controls. The sensitivity and specificity of the six clinical subscales were 63.0-77.0% and 66.7-79.9%, respectively. The combined total score of the six clinical subscales, had a sensitivity of 80.0% and specificity of 79.9%. Conclusion: The discriminative power of K-AARS for the diagnosis of ADHD in adults was excellent, and K-AARS and the empirical diagnosis of adults can be useful in diagnosing ADHD in adulthood.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF

A Study of the Validity of and Cut-Off Scores for the Korean Version of Asperger Syndrome Diagnostic Scale (한국판 아스퍼거 증후군 진단척도의 타당화 및 진단 분할점 산출)

  • Kim, Ha-Na;Shin, Min-Sup
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.22 no.2
    • /
    • pp.81-88
    • /
    • 2011
  • Objectives : This study examined the reliability and validity of the Korean version of Asperger Syndrome Diagnostic Scale (K-ASDS), to calculate the cut-off score in the diagnosis of Asperger syndrome. Further, we examined classification error rate when applying cut-off scores. Methods : One hundred sixty-seven children participated in this study, including 46 with Asperger syndrome, 26 with PDD or PDD NOS, 43 with ADHD, and 52 normal children. Results : An ANCOVA demonstrated no significant differences in the K-ASDS total score between the Asperger and the PDD & PDD NOS groups. However, these groups did show significantly higher scores than the ADHD and normal groups. Among the five subscales on the K-ASDS, the Asperger group obtained significantly higher scores on the language and cognition subscales than the PDD & PDD NOS groups. Two scales were found to be useful in distinguishing the Asperger group from the PDD & PDD NOS group through a discriminant analysis. According to an analysis of ROC curve, the cut-off score on the K-ASDS for the diagnosis of PDD including Asperger syndrome was 121. Conclusion : We discussed that K-ASDS has pretty limit.

A Study on Discriminant Function of KWIS Subscales in Schizophrenic Patients (정신분열증 환자에 있어서 KWIS 하위검사 판별기능에 관한 연구)

  • Lee, Jung-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 1990
  • The purpose of this article was to determine the discriminant function analysis of the Korean Wechsler Intelligence Scale(KWIS) for 110 normal controls and 98 schizophrenics. Of special interest was to verify the clinical discriminant power of two subtests of the KWIS(Vacabulary and Digit Symbols) and Zung' s Self-rating Anxiety Scale(SAS). Four major hypotheses were postulated. The normal control group would show higher scores than the schizophrenics ; mean scores on both Vocabulary and Digit Symbol. The mean difference in Digit Symbol between the two groups would be greater than that in the Vacabulary. There would be no significant relation among Digit Symbol. Vacabulary. and Anxiety. The most powerful discriminant power would be expected from subtest of Digit Symbol. The mean discriminant scores were - 1.34425 for the control subjects. 1.34425 for the schizophrenics. The correctly discriminated percentage was 89.1% for the control subjects. 90.8% for the schizophrenics. From the findings it was concluded that both Digit Symbol and Vocabulary scales had strong diagnostic value but the former was more powerful than the latter. However. the Anxiety scales had less diagnostic value.

  • PDF

Trends in Monoclonal Antibody Production Using Various Bioreactor Systems

  • Jyothilekshmi, I.;Jayaprakash, N.S.
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.349-357
    • /
    • 2021
  • Monoclonal antibodies are widely used as diagnostic reagents and for therapeutic purposes, and their demand is increasing extensively. To produce these proteins in sufficient quantities for commercial use, it is necessary to raise the output by scaling up the production processes. This review describes recent trends in high-density cell culture systems established for monoclonal antibody production that are excellent methods to scale up from the lab-scale cell culture. Among the reactors, hollow fiber bioreactors contribute to a major part of high-density cell culture as they can provide a tremendous amount of surface area in a small volume for cell growth. As an alternative to hollow fiber reactors, a novel disposable bioreactor has been developed, which consists of a polymer-based supermacroporous material, cryogel, as a matrix for cell growth. Packed bed systems and disposable wave bioreactors have also been introduced for high cell density culture. These developments in high-density cell culture systems have led to the monoclonal antibody production in an economically favourable manner and made monoclonal antibodies one of the dominant therapeutic and diagnostic proteins in biopharmaceutical industry.