• 제목/요약/키워드: diagnostic rule-base

검색결과 11건 처리시간 0.028초

퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선 (Performance Improvement of Multiple Observer based FDIS using Fuzzy Logic)

  • 류지수;이기상
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.444-451
    • /
    • 1999
  • A diagnostic rule-base design method for enhancing fault detection and isolation performance of multiple obsever based fault detection isolation schemes (FIDS) is presented. The diagnostic rule-base has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises a rule base and a fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic with threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rult-base. The suggested scheme is applied to the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

한의 진단 모델의 추론 과정에서 발생하는 불확실한 진단 지식의 처리 (Uncertain Knowledge Processing for Oriental Medicine Diagnostic Model)

  • 신양규
    • Journal of the Korean Data and Information Science Society
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 1997
  • 전문가 시스템에서의 추론은 주로 IF-THEN 형태의 규칙을 기반으로 하는 지식베이스에 기초한다. 그러나, 한의 전문가 시스템의 지식은 불확실한 지식 특히 애매한 개념의 지식을 많이 포함하고 있으므로 이에 대한 처리가 요구된다. 본 논문에서는 한의 진단 과정을 추론에 기준하여 분석하고 한의 진단 과정에서 발생하는 불확실한 진단 지식을 제약 조건 논리 프로그래밍언어의 일종인 CLP( R ) 언어를 이용하여 표현하고 처리하는 방법을 제안하였다.

  • PDF

실리콘 유입변압기 진단을 위한 전문가시스템 개발 (Development of the Expert System for Diagnosing Silicone Oil-filled Transformer)

  • 문종필;김재철;임태훈
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.55-62
    • /
    • 2004
  • 본 논문에서는 유중가스 분석법을 이용하여 실리콘 유입변압기를 효과적으로 진단할 수 있는 전문가 시스템의 개발에 관하여 연구하였다. 변압기 진단 방법은 유입기기에 대한 진단 방법으로서 현재까지 많은 연구가 진행되어 왔고 비교적 효과적인 분석법으로서 신뢰를 얻고 있는 유중가스분석법을 이용하였다. 그러나 유중가스 분석법은 경계 및 규칙의 불확실성이 필연적이기 때문에 이를 처리하기 위하여 소속정도 및 퍼지척도를 적용하여 해결하였다. 개발한 전문가 시스템은 크게 지식베이스 모듈, 추론엔진 모듈, 사용자 인터페이스 모듈로 이루어져 있으며, 지식베이스 모듈은 규칙을 이용한 지식표현을 사용하였고, 추론엔진 모듈은 후방향 추론을 이용하고, 퍼지규칙을 도입하였다. 사용자 인터페이스 모듈은 현장의 사용자가 쉽게 사용할 수 있도록 GUI 환경으로 구성하였다. 또한 변압기 개개의 이력 관리를 통하여 좀 더 효과적인 진단을 할 수 있도록 전문가 시스템을 데이터베이스와 연계하였다. 제안한 전문가 시스템에 대하여 실리콘유의 유중가스 데이터를 이용하여 검증한 결과 모든 사례에 대하여 정확한 판단 결과를 얻음으로써 실리콘 유입변압기를 효과적으로 진단할 수 있음을 증명하였다.

유중가스분석법을 이용한 실리콘 유입변압기 고장진단 전문가 시스템 (A Fault Diagnostic Expert System for Silicone Oil-filled Transformer Using Dissolved Gas Analysis)

  • 문종필;김재철;최준호;전영재;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.374-376
    • /
    • 2001
  • In this paper, we developed the fault diagnostic expert system of silicone-immersed transformer using dissolved gas analysis. The knowledge base module consists of the knowledge using the rule: if Then . The inference engine uses the fuzzy rule for the management of uncertainty of the boundary and rule and derivate the Belief and Plausibility of the normality and fault using Dempster-Shafer theory. The expert system is connected to the database and it can manages the history of gas-data of the transformer.

  • PDF

Contextual information 을 이용한 P파 검출에 관한 연구 (Improvement of ECG P wave Detection Performance Using CIR(Contextusl Information Rule-base) Algorithm)

  • 이지연;김익근
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.235-240
    • /
    • 1996
  • The automated ECG diagnostic systems that are odd in hospitals have low performance of P-wave detection when faced with some diseases such as conduction block. So, the purpose of this study was the improvement of detection performance in conduction block which is low in P-wave detection. The first procedure was removal of baseline drift by subtracting the median filtered signal of 0.4 second length from the original signal. Then the algorithm detected R peak and T end point and cancelled the QRS-T complex to get'p prototypes'. Next step was magnification of P prototypes with dispersion and detection of'p candidates'in the magnified signal, and then extraction of contextual information concerned with P-waves. For the last procedure, the CIR was applied to P candidates to confirm P-waves. The rule base consisted of three rules that discriminate and confirm P-waves. This algorithm was evaluated using 500 patient's raw data P-wave detection perFormance was in- creased 6.8% compared with the QRS-T complex cancellation method without application of the rule base.

  • PDF

퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선 (Performance Improvement of MOS type FDIS using Fuzzy Logic)

  • 류지수;박태건;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.410-413
    • /
    • 1998
  • A passive approach for enhancing fault detection and isolation performance of multiple observer based fault detection isolation schemes(FDIS) is proposed. The FDIS has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises of a rule base and fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic and threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rule base. The suggested scheme is applied for the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

공작기계 고장 진단 전문가 시스템 개발 (Development of an Expert System for Diagnosing Machine Tool Failures)

  • 서동규;강무진
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.217-224
    • /
    • 1999
  • Trouble shooting of modern machine tools equipped with sophisticated electronic as well as mechanical parts is so difficult that it is usually depends upon the experience and accumulated knowledge of the diagnosing persons. On the other hand, tool users are scattered in wide area, which makes it expensive for a machine tool maker to run a vast service network. An unmanned diagnosis system to which users can have access at all times could be an efficient alternative. For this purpose, a rule-based expert system for diagnosing machine tools is developed. This paper describes the structure of diagnostic knowledge, the rule firing mechanism, the diagnosis flow, and user query process. An example shows the feasibility of problem solving on site without help of a service expert from machine tool maker.

  • PDF

한의진단 Ontology 구축을 위한 추론과 탐색에 관한 연구 (Study on Inference and Search for Development of Diagnostic Ontology in Oriental Medicine)

  • 박종현
    • 동의생리병리학회지
    • /
    • 제23권4호
    • /
    • pp.745-750
    • /
    • 2009
  • The goal of this study is to examine on reasoning and search for construction of diagnosis ontology as a knowledge base of diagnosis expert system in oriental medicine. Expert system is a field of artificial intelligence. It is a system to acquire information with diverse reasoning methods after putting expert's knowledge in computer systematically. A typical model of expert system consists of knowledge base and reasoning & explanatory structure offering conclusion with the knowledge. To apply ontology as knowledge base to expert system practically, consideration on reasoning and search should be together. Therefore, this study compared and examined reasoning, search with diagnosis process in oriental medicine. Reasoning is divided into Rule-based reasoning and Case-based reasoning. The former is divided into Forward chaining and Backward chaining. Because of characteristics of diagnosis, sometimes Forward chaining or backward chaining are required. Therefore, there are a lot of cases that Hybrid chaining is effective. Case-based reasoning is a method to settle a problem in the present by comparing with the past cases. Therefore, it is suitable to diagnosis fields with abundant cases. Search is sorted into Breadth-first search, Depth-first search and Best-first search, which have respectively merits and demerits. To construct diagnosis ontology to be applied to practical expert system, reasoning and search to reflect diagnosis process and characteristics should be considered.

퍼지추론을 이용한 전동기구동 펌프시스템의 고장진단 (Fault Diagnosis of motor driven pump system based on fuzzy inference)

  • 조윤석;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.689-691
    • /
    • 1995
  • In this paper, a fault detection and isolation unit(FDIU) for a centrifugal pump system driven by DC-motor is proposed. The proposed scheme can be classified into the dedicated observer scheme(DOS). A fuzzy logic based inference engine is adopted for the isolation of each faults. Having the fuzzy inference engine, the proposed FDIU resolve a few important problems of the conventional DOSs with conventional two valued logic. The ouputs of the proposed FDIU are not "ith fault occurred" but the grade of memberships that indicate the consistency of observered symptoms(residuals) with each fault symptoms stored in the rule base. The ouputs can easily be transferred to the ranking of the fault possibilities and it will provide very useful informations in monitoring the process. The simulation results show that the FDIU has very good diagnostic ability even in the noisy environment.

  • PDF

Fossa navicularis magna detection on cone-beam computed tomography

  • Syed, Ali Z.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • 제46권1호
    • /
    • pp.47-51
    • /
    • 2016
  • Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed.