• 제목/요약/키워드: diagnostic reference level (DRL)

검색결과 25건 처리시간 0.019초

진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구 (A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level)

  • 박혜민;윤용수;김은혜;정회원;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가 (Assessment of DRL for Computed Tomography in Local Hospital)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.619-625
    • /
    • 2022
  • 영상의학 분야에서 컴퓨터단층촬영(Computed Tomography, CT) 검사는 가장 보편화된 검사 방법 중의 하나이고 병원에서 이용 빈도가 매우 높은 검사 방법 중의 하나이다. 그러나 다른 검사 방법에 비해 매우 높은 방사선 피폭을 동반한다. 피폭 저감화를 위해서 CT 검사가 꼭 필요한 경우만 검사를 시행하는 방법과 꼭 필요해서 검사를 시행하는 경우에도 검사의 목적에 부합하고 적은 선량으로 검사를 시행할 수 있는 프로토콜을 사용해야 한다. 본 연구에서는 지역의 대표적 종합병원에서 사용하고 있는 가장 최신의 방사선량 사용정보를 알아보고 진단기준수준(Dignostic Reference Level, DRL)을 개발하고자 하였다. 실험결과 두부 CT, 복부 CT검사에서 DLP는 NRPB(U.K) 와 Korea DRL보다 높게 나타났다. 흉부 CT의 사용 DLP 값은 CT장치 3종 모두 낮게 나타났다. 해당 병원에서는 CT 검사 시 피폭 저감화를 위한 노력을 해야 하는 것을 알 수 있었고 특히 두부 CT, 복부 CT에서 피폭 저감의 노력이 필요하다고 판단한다.

흉부방사선검사의 목표노출지수 설정을 위한 연구 (A Study to Establish Target Exposure Index for Chest Radiography)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.167-173
    • /
    • 2024
  • This study purpose to establish an appropriate target exposure index(EIT) using dose area product(DAP) and exposure index(EI) based on chest radiography. First, the system response experiment was conducted with radiation quality of RQA5 to compare the dosimetry and dose area product of equipment. Next, EI and DAP were acquired and analyzed while varying the dose in the diagnostic at 70kVp using a human body model phantom. The signal to noise ratio(SNR) of the obtained results was analyzed in the diagnostic with in the diagnostic reference level(DRL) application range. The DRL at percentage 25% had a dose of 0.17 mGy and EI was 83, and at percentage 75% the dose was 0.68 mGy and EI was 344. As the dose increased, the SNR in the subdiaphragm increased. To set the EIT, calibration must first be performed using a dosimeter and set within the DRL range to reflect the needs of the medical institution.

디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰 (A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography)

  • 정연진;주영철;홍동희;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.897-904
    • /
    • 2022
  • 본 연구의 목적은 디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준(DRL)에서 제시하는 검사 조건과 현재 임상에서 적용하고 있는 검사 조건 적용 시 선량과 화질의 차이 비교를 통해, 디지털 방사선환경에 적절한 두부 방사선검사의 조건에 대해 고찰하고자 한다. 본 연구는 두부모형팬텀을 대상으로 하였으며, 조사 조건은 임상에서 사용하는 조건(Clinic)과 DRL값(DRL75), DRL 평균값(DRLmean)으로 구분하여 실험하였다. 선량은 입사표면선량(ESD)을 측정하였고, 화질은 신호 대 잡음비와 대조도 대 잡음비를 측정하여 비교 분석하였다. 검사 조건 변화에 따른 skull AP ESD의 평균값은 Clinic 1214.03±4.21 µGy, DRL75 301 7.83±8.14 µGy, DRLmean 2283.50±7.09 µGy이었으며, skull Lat. ESD의 평균값은 Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, DRLmean 1654.43±6.48 µGy로 통계적으로 유의한 것으로 나타났다(p<0.01). 안와, 상악동, 전두동, 터키안장에서 측정한 SNR과 CNR의 평균값은 통계적으로 유의하였다(p<0.01). 본 연구 결과 임상에서 사용하는 조건이 DRL에 비해 AP는 약 58%, Lat.은 약 70% 정도의 낮은 선량 수치를 나타내었으며, 화질 측면에서 정성적인 차이가 없었다. 본 연구를 통해 디지털 방사선 환경에 적합한 새로운 진단참고수준에 대해 고려해 볼 필요가 있으며, 그에 따른 선량의 저감화가 이루어져야 할 것으로 사료된다.

X-선 단순 Series 촬영 시 피폭 선량 평가 (Assessment of Radiation Dose Due to X-Ray Simple Series Examinations)

  • 강은보;황인철;신운재
    • 한국방사선학회논문지
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 2014
  • 진단영상의학에서 일반영상촬영의 경우 각각의 부위를 연속(series)촬영으로 검사하는 경우가 대부분이다. 그러나 환자선량권고량(DRL)의 경우 각 부위의 전후(AP)방향과 측면(lateral)자세의 촬영 측정값만이 설정되어있는 것이 현실이다. 병원에서는 환자의 연속 촬영에 의해 누적 선량이 발생되며, 이는 환자선량권고량(DRL)과 누적된 피폭선량을 비교할 수 없거나, 과소평가할 수 있다. 본 연구에서 각 부위별 연속촬영의 누적선량을 측정한 결과, 조사야에 포함된 경우 입사표면선량(ESD)을 유효선량으로 변환하면 공중의 선량한도(Individual dose)의 최대 38.06%에서 최소 0.23%까지 측정되었다. 그리고 조사야에 포함되지 않은 각 부위의 입사표면선량(ESD)을 유효선량(Effective dose)으로 변환한 경우 공중의 선량한도(Individual dose)의 최대 5%에서 최소 0.04%까지 측정되었다. 연구결과 각 부위별 연속촬영에서 입사표면선량(ESD)이 많이 증가하는 것을 알 수 있다. 따라서 병원에서는 환자선량권고량(DRL)을 구체적으로 설정할 필요가 있으며, 불필요한 검사를 줄이기 위해 환자 촬영 order의 세분화가 필요하다고 판단된다. 또한, 여러 부위의 검사에서는 정확한 조사야의 필요성이 강조된다.

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석 (Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program)

  • 김영은;이정화;홍선숙;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Glass Dosimeter를 이용한 환자피폭선량에 관한 분석 (Analysis of Patient Exposure dose with Glass Dosimeter)

  • 김재인;최원근;장성원;오창섭;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가 (Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program)

  • 정희철;이삼열
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.807-812
    • /
    • 2018
  • 본 연구에서는 국가에서 권고하고 있는 일발촬영 진단참고준위 설정에 사용된 조건을 조사하여 PCXMC v2.0 프로그램을 이용하여 유효선량을 측정하고 생물학적 평가를 해보고자 한다. 그 결과 ICRP 60에서 유효선량은 가장 높은 Pelvis AP는 0.794 mSv 가장 낮은 Chest PA는 0.050 mSv이었다. ICRP 103에서는 남성이 가장 높은 T-Spine AP는 0.733 mSv 가장 낮은 Chest PA는 0.057 mSv, 여성은 가장 높은 T-Spine AP는 0.906 mSv 가장 낮은 Chest PA는 0.052 mSv이었다. 남녀 성인 40세 기준으로 일반촬영별 유효선량을 평가 해 보았고, 선량한도의 제한을 받지 않는 의료피폭이라도 방사선위해의 확률적 영향을 최소화하기 위해서 선량을 권고량 이하로 유지하여 국민의 의료피폭을 줄이기 위해 노력이 필요할 것으로 사료된다.

심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가 (Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea)

  • 김정수;이종혁;정혜경;김정민;조병렬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.27-33
    • /
    • 2016
  • 심장혈관 조영술과 인터벤션은 현대 성인병의 증가로 급격히 증가하고 있다. 심장혈관 인터벤션은 장시간 동일 부위에 방사선을 조사하는 검사로 방사선으로 인한 피부상해를 일으킬 수 있다. 본 연구에서는 의료기관의 심장혈관 인터벤션의 진단참조준위를 조사하여 환자의 피폭선량을 감소시키는 도구로 사용하고자 한다. 본 연구는 147명의 환자에서 심장혈관 조영술과 인터벤션을 대상으로 누적 투시시간, 누적 투시면적선량, 영상촬영을 위한 면적선량, 누적 면적선량, 공기커마, 동영상 수, 총 영상 수에 대한 정보를 획득하여 진단참조준위를 설정하였다. 심장혈관 조영술의 진단참조준위와 인터벤션의 진단참조준위에 해당하는 면적선량 값은 각각 $44.4 Gy{\cdot}cm2$$298.6Gy{\cdot}cm2$로 나타났고 투시시간에 대한 진단참조준위는 각각 191.5 sec와 1935.3 sec로 나타났다. 진단참조준위는 반드시 넘으면 안 되는 값은 아니다. 하지만 진단참조준위를 제정하여 의료 기관에서 사용하고 있는 선량의 참조 값을 설정하고 이를 검토하는 과정은 환자의 불필요한 피폭선량을 감소시키는데 기여할 것이다.