• 제목/요약/키워드: diagnostic performance

검색결과 945건 처리시간 0.025초

Simultaneous Estimation of the Fat Fraction and R2* Via T2*-Corrected 6-Echo Dixon Volumetric Interpolated Breath-hold Examination Imaging for Osteopenia and Osteoporosis Detection: Correlations with Sex, Age, and Menopause

  • Donghyun Kim;Sung Kwan Kim;Sun Joo Lee;Hye Jung Choo;Jung Won Park;Kun Yung Kim
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.916-930
    • /
    • 2019
  • Objective: To investigate the relationships of T2*-corrected 6-echo Dixon volumetric interpolated breath-hold examination (VIBE) imaging-based fat fraction (FF) and R2* values with bone mineral density (BMD); determine their associations with sex, age, and menopause; and evaluate the diagnostic performance of the FF and R2* for predicting osteopenia and osteoporosis. Materials and Methods: This study included 153 subjects who had undergone magnetic resonance (MR) imaging, including MR spectroscopy (MRS) and T2*-corrected 6-echo Dixon VIBE imaging. The FF and R2* were measured at the L4 vertebra. The male and female groups were divided into two subgroups according to age or menopause. Lin's concordance and Pearson's correlation coefficients, Bland-Altman 95% limits of agreement, and the area under the curve (AUC) were calculated. Results: The correlation between the spectroscopic and 6-echo Dixon VIBE imaging-based FF values was statistically significant for both readers (pc = 0.940 [reader 1], 0.908 [reader 2]; both p < 0.001). A small measurement bias was observed for the MRS-based FF for both readers (mean difference = -0.3% [reader 1], 0.1% [reader 2]). We found a moderate negative correlation between BMD and the FF (r = -0.411 [reader 1], -0.436 [reader 2]; both p <0.001) with younger men and premenopausal women showing higher correlations. R2* and BMD were more significantly correlated in women than in men, and the highest correlation was observed in postmenopausal women (r = 0.626 [reader 1], 0.644 [reader 2]; both p < 0.001). For predicting osteopenia and osteoporosis, the FF had a higher AUC in men and R2* had a higher AUC in women. The AUC for predicting osteoporosis was highest with a combination of the FF and R2* in postmenopausal women (AUC = 0.872 [reader 1], 0.867 [reader 2]; both p < 0.001). Conclusion: The FF and R2* measured using T2*-corrected 6-echo Dixon VIBE imaging can serve as predictors of osteopenia and osteoporosis. R2* might be useful for predicting osteoporosis, especially in postmenopausal women.

Comparison of Monoexponential, Biexponential, Stretched-Exponential, and Kurtosis Models of Diffusion-Weighted Imaging in Differentiation of Renal Solid Masses

  • Jianjian Zhang;Shiteng Suo;Guiqin Liu;Shan Zhang;Zizhou Zhao;Jianrong Xu;Guangyu Wu
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.791-800
    • /
    • 2019
  • Objective: To compare various models of diffusion-weighted imaging including monoexponential apparent diffusion coefficient (ADC), biexponential (fast diffusion coefficient [Df], slow diffusion coefficient [Ds], and fraction of fast diffusion), stretched-exponential (distributed diffusion coefficient and anomalous exponent term [α]), and kurtosis (mean diffusivity and mean kurtosis [MK]) models in the differentiation of renal solid masses. Materials and Methods: A total of 81 patients (56 men and 25 women; mean age, 57 years; age range, 30-69 years) with 18 benign and 63 malignant lesions were imaged using 3T diffusion-weighted MRI. Diffusion model selection was investigated in each lesion using the Akaike information criteria. Mann-Whitney U test and receiver operating characteristic (ROC) analysis were used for statistical evaluations. Results: Goodness-of-fit analysis showed that the stretched-exponential model had the highest voxel percentages in benign and malignant lesions (90.7% and 51.4%, respectively). ADC, Ds, and MK showed significant differences between benign and malignant lesions (p < 0.05) and between low- and high-grade clear cell renal cell carcinoma (ccRCC) (p < 0.05). α was significantly lower in the benign group than in the malignant group (p < 0.05). All diffusion measures showed significant differences between ccRCC and non-ccRCC (p < 0.05) except Df and α (p = 0.143 and 0.112, respectively). α showed the highest diagnostic accuracy in differentiating benign and malignant lesions with an area under the ROC curve of 0.923, but none of the parameters from these advanced models revealed significantly better performance over ADC in discriminating subtypes or grades of renal cell carcinoma (RCC) (p > 0.05). Conclusion: Compared with conventional diffusion parameters, α may provide additional information for differentiating benign and malignant renal masses, while ADC remains the most valuable parameter for differentiation of RCC subtypes and for ccRCC grading.

도시재생 공동이용시설의 지속적인 운영을 위한 평가지표 제안 (Performance Evaluation Criteria for the Sustainable Operation of Community Facilities in Urban Regeneration)

  • 이정은;박성은;박윤미
    • 토지주택연구
    • /
    • 제15권3호
    • /
    • pp.79-95
    • /
    • 2024
  • 지난 10년간 전국적으로 도시재생사업이 활발하게 진행되며 지역 및 공동체 활성화를 위한 공동이용시설도 대거 조성되었다. 최근 들어 공동이용시설의 지속적인 운영에 적절한 도움과 처방을 제공하기 위한 진단이 반드시 필요하다고 강조되고 있는데, 이를 위한 매뉴얼이나 전국적으로 통용할 만한 큰 방향은 여전히 부재한 상황이다. 이에 따라 본 연구는 공동이용시설의 주기적인 운영 진단에 활용할 수 있는 평가지표와 지표 활용 방안을 제안하는 것을 목적으로 하였다. 먼저, 국내 선행연구 검토를 통해 공동이용시설의 가치와 방향을 정립하고, 국내외 선행연구 및 타 공공시설 운영관리 문헌을 종합하여 후보지표를 마련하였다. 이후 간단한 전문가 자문을 통해 예비지표 및 지표체계를 결정한 후 다수의 전문가를 대상으로 설문을 진행하여 최종적인 평가지표를 도출하였다. 설문 결과, 시설 운영을 통한 '가치창출'과 실질적인 '운영관리' 점검이 진단의 중요한 두 핵심으로 여겨졌고, '가치창출' 안에서는 지역공동체 활력 증대, 지역 역량 강화, 지역 맞춤 기능 제공, 지역경제 기여, '운영관리' 안에서는 운영체계, 회계관리, 운영인력, 경제성 및 지속성이 주요 평가 항목으로 나타났다. 본 연구는 최종 결정된 평가지표와 지표별 구득 가능 자료원을 포함한 진단기준안을 제안 후 활용성 검증을 위한 시범 진단도 진행하였다. 또한, 연구는 진단기준안의 활용 방향과 함께 본 연구의 방법을 활용하여 시설별 특성에 맞는 지표를 적용하는 방안도 제안하고 있다.

머신러닝과 GLCM을 이용하여 갑상샘 초음파영상의 결절분류에 관한 연구 (Image Classification of Thyroid Ultrasound Nodules using Machine Learning and GLCM)

  • 정예나;예수영
    • 한국방사선학회논문지
    • /
    • 제18권4호
    • /
    • pp.317-325
    • /
    • 2024
  • 본 연구는 갑상샘 초음파 영상에서 정상영상과 결절영상을 GLCM과 머신러닝을 이용하여 분류하고자 하였다. 부산 소재 S병원에 내원하여 갑상샘 초음파를 이용하여 갑상선 결절 진단받은 600명을 대상으로 연구를 진행하였다. 갑상샘 초음파 영상에서 ROI 50 X 50 픽셀 크기로 설정 하고 GLCM을 이용하여 21개의 파라메터와 4가지 각도를 사용하여 갑상샘 정상 패턴과 갑상샘 결절 패턴을 분석하였다. 분석된 자료는 MATLAB 모델 중 SVM모델과 KNN모델을 이용하여 진단 결과가 정상과 결절을 구별할 수 있도록 하였다. 그 결과 갑상샘 결절 분류율의 정확도는 SVM모델은 94%, KNN모델은 91%으로 나타났다. 두 모델 모두 90% 이상의 정확도를 나타내었는데 이는 갑상샘 정상과 갑상샘 결절의 분류를 위해 머신러닝을 이용할 경우 분류율이 우수하다는 것을 알 수 있다. ROC곡선에서도 SVM 모델에 대한 ROC 곡선은 전반적으로 KNN모델과 비교해 ROC곡선이 높으며, 이는 KNN모델보다 표본 내 성능이 높다는 결과가 나타났다. 이러한 결과를 바탕으로 SVM 모델이 갑상샘 결절 진단에서 높은 정확도를 보여주었다. 이 결과는 향후 의료 진단보조 도구로서의 연구에 기초자료로 활용될 수 있으며, 머신러닝 기술이 의료 서비스의 질적 개선에 기여할 것으로 기대된다.

Sequencing Methods to Study the Microbiome with Antibiotic Resistance Genes in Patients with Pulmonary Infections

  • Tingyan Dong;Yongsi Wang;Chunxia Qi;Wentao Fan;Junting Xie;Haitao Chen;Hao Zhou;Xiaodong Han
    • Journal of Microbiology and Biotechnology
    • /
    • 제34권8호
    • /
    • pp.1617-1626
    • /
    • 2024
  • Various antibiotic-resistant bacteria (ARB) are known to induce repeated pulmonary infections and increase morbidity and mortality. A thorough knowledge of antibiotic resistance is imperative for clinical practice to treat resistant pulmonary infections. In this study, we used a reads-based method and an assembly-based method according to the metagenomic next-generation sequencing (mNGS) data to reveal the spectra of ARB and corresponding antibiotic resistance genes (ARGs) in samples from patients with pulmonary infections. A total of 151 clinical samples from 144 patients with pulmonary infections were collected for retrospective analysis. The ARB and ARGs detection performance was compared by the reads-based method and assembly-based method with the culture method and antibiotic susceptibility testing (AST), respectively. In addition, ARGs and the attribution relationship of common ARB were analyzed by the two methods. The comparison results showed that the assembly-based method could assist in determining pathogens detected by the reads-based method as true ARB and improve the predictive capabilities (46% > 13%). ARG-ARB network analysis revealed that assembly-based method could promote determining clear ARG-bacteria attribution and 101 ARGs were detected both in two methods. 25 ARB were obtained by both methods, of which the most predominant ARB and its ARGs in the samples of pulmonary infections were Acinetobacter baumannii (ade), Pseudomonas aeruginosa (mex), Klebsiella pneumoniae (emr), and Stenotrophomonas maltophilia (sme). Collectively, our findings demonstrated that the assembly-based method could be a supplement to the reads-based method and uncovered pulmonary infection-associated ARB and ARGs as potential antibiotic treatment targets.

시각 주의력과 청각 주의력의 차이를 보이는 주의력 결핍.과잉활동장애 아동의 인지기능과 정서 및 행동 문제 (The Cognitive Performance, Emotional and Behavioral Problems of the Children with ADHD Showing the Difference between Visual and Auditory Attention)

  • 손정우
    • 생물정신의학
    • /
    • 제13권2호
    • /
    • pp.70-81
    • /
    • 2006
  • 목 적: 시각 주의력과 청각 주의력에서 차이를 보이는 주의력결핍 과잉활동장애(ADHD) 아동의 인지 기능 및 정서, 행동 문제에 대해 연구하고자 한다. 방 법: 동반 질환이 없는 ADHD 아동 98명을 대상으로 '주의력장애 진단시스템(ADS)' 을 실시하여 시각 주의력과 청각 주의력을 측정한 뒤, ADS의 누락 오류와 오경보 오류를 이용하여 이들을 1) 청각 누락 오류 및 오경보 오류가 시각 누락 오류 및 오경보 오류보다 높은 군(AA군) 2) 시각 누락 오류 및 오경보 오류가 청각 누락 오류 및 오경보 오류보다 높은 군(VV군) 3) 1), 2)에 해당하지 않는 군(M군)의 3개 군으로 분류하였다. 세 군 간에 '한국판 웩슬러 아동용 지능 검사(KEDI-WISC)' 의 소검사 결과와 '한국판 아동-청소년 행동평가척도(K-CBCL)' 의 여러 하위 소척도의 점수를 비교하였다. 또한, 전체 아동을 대상으로 시각 누락 오류, 청각 누락 오류, 시각 오경보 오류, 청각 오경보 오류와 KEDI-WISC의 소검사 점수, K-CBCL의 하위 영역 점수 간의 상관관계를 조사하였다. 결 과: 다음의 결과를 얻었다. 1) AA군은 10명, M군은 32명, VV군은 56명이었다. 2) KEDI-WISC의 소검사 점수 비교에서는 VV군의 점수가 나머지 두 군보다 높았다. 특히 언어성 지능(p=.039)에서는 VV군이 AA군보다 유의하게 높았고 토막짜기(p=.015), Kaufman의 요인 2(p=.045), 동작성 지능(p=.004)에서는 VV군이 M군보다 유의하게 높았으며 전체 지능(p=.004)에서는 VV군이 M군 및 AA군보다 유의하게 높았다. 3) K-CBCL의 하위 소척도 점수 비교에서는 신체증상 소척도 점수를 제외한 전 영역에서 VV군의 점수가 나머지 두 군보다 높았다. 특히 사회성 소척도(p=.041)에서는 VV군이 AA군보다 유의하게 높았으며 위축 소척도(p=.021)에서는 VV군이 AA군보다 유의하게 낮았다. 4) 시각 누락 오류, 시각 오경보 오류와 KEDI-WISC의 소검사 점수 간에는 유의한 상관관계가 존재하지 않았다. 한편 청각 누락 오류, 청각 오경보 오류와 KEDI-WISC의 소검사 점수 간에는 유의한 상관관계를 보이는 영역이 매우 많았다. 5) 시각 누락 오류, 시각 오경보 오류와 K-CBCL의 소검사 점수 간에는 시각 누락 오류와 사고의 문제 소척도(r=.205, p=.043) 간에만 유의한 상관관계가 존재하였다. 청각 누락 오류와는 사회성 소척도(r=-.319, p=.001), 사회적 미성숙 소척도(r=.206, p=.042), 사고의 문제 소척도(r=.235, p=.021) 간에 유의한 상관관계가 있었다. 청각 오경보 오류와는 사회성 소척도(r=-.241, p=.017) 및 주의집중문제 소척도(r=.235, p=.020) 간에 유의한 상관관계가 있었다. 결 론: 청각 주의력이 상대적으로 더 나은 ADHD 아동이 다른 아동에 비해 인지 기능이 더 좋고 정서 및 행동 문제가 적었다. 향후 시각 주의력과 청각 주의력에 차이를 보이는 ADHD 아동에 대해 보다 체계적인 연구가 필요할 것이다.

  • PDF

Helicobacter pylori 감염 유무와 정도 반영에 대한 C-14와 C-13 요소호기검사 정량치 비교 (Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection)

  • 임석태;김동욱;정환정;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권3호
    • /
    • pp.229-234
    • /
    • 2008
  • 목적: 최근 들어 H. pylori에 의한 염증이 진행되면 만성 위축성위염을 일으키고 나아가서는 위암을 일으킨다는 학설이 대두되면서 UBT의 이용이 증가되고 있다 저자들은 H. pylori 감염과 분포 정도를 평가하는데 C-14 와 C-13 UBT의 진단성능과 유용성에 차이가 있는지를 알아보았다. 대상 및 방법: 소화불량, 위 팽만감, 상복부동통 등의 상부위장관증상이 있어 위십이지장내시경을 시행 받은 환자 중 균박멸요법을 시행 전에 조직검사, C-14 및 C-13 UBT를 모두 시행 받은 38명(남:녀=28:10, 나이; $53.4{\pm}13.0$세)을 대상으로 하였다. 조직생검 결과를 최적 기준으로 하여 C-14 와 C-13 UBT의 진단성능을 비교하였고 Wyatt법에 의한 조직검사의 등급(0-4)과 C-14 및 C-13 UBT의 정량적 측정치와의 상관관계를 비교하였다. 결과: 조직생검에서 25명(65.8%)에서 H. pylori 감염에 대한 양성을 보였다. H. pylori 감염 진단하는데 C-14 UBT는 민감도 92.0%, 특이도 92.3%, 양성예측도 95.8%, 음성예측도 91.7%, 정확도는 92.1% 이었으나, C-13 UBT는 민감도 96.0%, 특이도 84.6%, 양성 예측도 92.3%, 음성예측도 91.7%, 정확도는 92.1% 이었다. 조직검사 등급에 따른 C-14 UBT 측정치와의 상관성이 C-13 UBT 측정치에 비하여 우수하였다(각각 r=0.948 vs r=0.818, p<0.001). 결론: H. pylori 감염을 진단하는데 C-14 와 C-13 UBT는 유의한 차이는 없으나 C-14 UBT 측정치가 H. pylori 감염 정도를 평가하는데 좀 더 유용할 것으로 생각된다.

Insulin 측정용 방사면역측정법 시약의 평가 (The Evaluation of Radioimmunoassay kits for Insulin)

  • 신용환;김윤현;이일규;김지영;석재동;신숙희
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2012
  • 혈중 Insulin 농도는 췌장 ${\beta}$세포의 인슐린 분비기능을 반영하고 당뇨병의 진단, 병태 파악, 내당능 이상의 원인감별에 유용한 지표이다. 핵의학검사실에서 사용하고 있는 혈중 Insulin 측정용 시약들은 제조회사마다 검사방법 뿐만 아니라 비용효과 측면, 정밀도 등 정도관리 측면에서도 다소 차이를 보이고 있다. 따라서 Insulin 측정용 방사면역측정법 시약들의 제조 회사별 비교를 통해 진단적 성능을 평가하고자 본 연구를 시행하였다. 2009년 8월 59명의 환자 검체를 대상으로 시행된 3개 제조회사(Biosource, Siemens, TFB)의 혈중 Insulin측정치와 2011년 12월 68명의 환자 검체를 대상으로 시행된 4개 제조회사(Immunotech, Izotope, BNIBT, Cisbio)의 혈중 Insulin측정치를 비교 평가하였다. 이들 7개 제조회사별 Insulin측정치에 대하여 정밀도, 회수율, 상관관계를 살펴보았으며 일부 인슐린 고농도 특이검체를 가지고 희석시험을 통해 혈중 Insulin측정치를 상호 비교 평가하였다. 혈중 Insulin 측정은 시약 내 설명서의 권고사항을 준수하여 실시하였으며 결과 검증을 위한 통계 프로그램은 SPSS 12.0을 이용하였다. 측정 내 정밀도는 Biosource, Siemens, TFB, Immunotech, Izotope, BNIBT, Cisbio 7개 제조회사 모두 5.0% 이하의 변이계수를 보였다. 회수율은 저, 중, 고 세가지 농도의 혈청에서 Biosource, Siemens, TFB시약이 각각 94.2~103.7%, 99.0~104.6%, 99.7~107.6% 구간을 보였고 Immunotech, Izotope, BNIBT, Cisbio 시약에서 각각 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% 구간의 회수율을 보였다. Biosource 시약을 기준으로 비교한 상관관계에서 Siemens 시약이 R2=0.96(P<0.01), TFB시약이 R2=0.99(P<0.01)를 보였으며 TFB 시약을 기준으로 비교한 상관관계에서는 BNIBT시약(R2=0.80, P<0.01)을 제외한 대부분의 시약에서 강한 상관관계(R2=0.96 이상, p<0.01)를 보였다. 200 ${\mu}IU/ml$ 이상 고농도 희석시험에서는 당뇨병환자 검체를 대상으로 했을 때 7개 제조회사 시약 모두 고농도값을 정상적으로 측정하였다. 하지만, 인슐린 종양 검체를 대상으로 측정한 검사에서는 TFB, Siemens, Izotope, Cisbio시약들은 고농도값을 정상적으로 측정하였지만 Biosource와 Immunotech 시약에서 각각 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$의 측정치를 보였다. 혈중 Insulin 측정용 방사면역측정법 시약들은 전반적으로 성능이 임상 적용 가능한 범위의 측정 정밀도를 보이면서, 우수한 회수율과 양호한 상관관계를 보였지만 일부 시약에서 고농도 특이검체를 대상으로 Insulin을 측정한 검사에서 고농도값을 제대로 측정하지 못했다. 따라서 여러가지 요인을 놓고 볼 때 비용 효과측면과 자동화 장비에 대한 호환성, 검사 반응시간등 각 검사실 환경에 맞는 시약과 진단적 성능이 보다 우수한 시약을 선정하여 사용한다면 정확하고 신속한 결과보고에 있어서 많은 도움이 된다고 사료된다.

  • PDF

무증상 성인에서 PET과 PET/CT를 이용한 암 진단 (Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers)

  • 정지인;조한별;심재용;최준영;이경한;김병태;최윤호
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권6호
    • /
    • pp.526-534
    • /
    • 2009
  • 목적: 무증상 성인을 대상으로 시행된 PET과 PET/CT 검사 결과를 분석하여 이들 검사의 암 조기 진단을 위한 선별검사로서의 유용성을 평가하고자 하였다. 대상 및 방법: 1998년 3월부터 2008년 2월까지 서울 소재 1개 대학병원에서 건강검진 프로그램의 일부로 시행된 PET과 PET/CT 검사자 중 1년 이상 추적관찰이 이루어진 5,091명을 대상으로 하였다. PET과 PET/CT 시행 후 1년 이내에 암이 확진된 경우를 조사하여 PET과 PET/CT의 판독결과와 비교하고 민감도와 특이도를 평가하였으며, 판독에서 명확한 결론을 내기 어려워 추가 검사를 권고한 경우를 분석하였다. 결과: PET 또는 PET/CT 검사 시행 후 1년이내에 암을 진단 받은 경우는 총 86건으로 전체 조사 대상의 1.7%(86/5,091)였다. PET과 PET/CT 검사를 합친 전체검사의 민감도는 48.8%였으며 특이도는 81.1%였다. PET 단독검사의 민감도와 특이도는 각각 46.2%, 81.4% 였으며, PET/CT 단독 검사의 민감도와 특이도는 각각 75.0%, 78.5%였다. 판독에서 암이 의심되었던 경우와 판독에서 암이 의심되지 않았던 경우를 비교하여 보았으나 암부위, 조직학적 진단, 암 병기 등에서 두 군 사이에 통계학적으로 유의한 차이가 없었다. PET과 PET/CT에서 양성 혹은 악성의 의미 있는 병변이 의심되거나 양성 및 악성을 구분하기 어려워 추가 검사를 권고한 경우는 전체의 19.3%(981/5,091)였다. 이중에서 두경부 및 상부 위장관 부위에 대한 추가 검사를 권고한 경우가 가장 많았다. 결론: 무증상 성인의 건강검진에서 사용한 PET과 PET/CT 의 암 진단 정확도는 중간 정도로 평가되었다. PET과 PET/CT의 효용성을 높이기 위해서는 검사 대상집단의 연령이나 위험요인과 같은 임상적 특성을 고려해야 할 것이다. 또한 검사법과 판독 기술의 향상이 필요하며, 검사에 대한 충분한 이해를 바탕으로 수진자가 현명한 선택을 하도록 하여야 한다.

국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석 (LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies)

  • 김동환;김보현;최준일;오순남;나성은
    • 대한영상의학회지
    • /
    • 제83권2호
    • /
    • pp.331-343
    • /
    • 2022
  • 목적 국소 치료 후 잔존 간세포암 진단을 위한 LI-RADS 치료 반응(liver imaging reporting and data system treatment response; 이하 LR-TR)과 modified Response Evaluation Criteria in Solid Tumors (이하 mRECIST) 기준의 진단능을 체계적으로 비교한다. 대상과 방법 MEDLINE과 EMBASE에서 역동적 조영증강 CT 또는 MRI를 이용하여 LR-TR과 mRECIST의 진단능을 개인 내 비교한 원저를 검색하였다. 생존 종양에 대한 참조 표준은 수술을 통한 병리 진단을 사용하였다. 각 기준의 생존 카테고리에 대한 메타분석적 통합 민감도와 특이도는 bivariate random-effects model을 통해 계산하였고 bivariate meta-regression을 통해 비교하였다. 결과 총 다섯 개의 포함된 연구들에서(430명 환자들 및 631개 치료된 병변들), LR-TR 생존 카테고리의 병변별 통합 민감도와 특이도는 58% (95% 신뢰구간, 45%-70%)와 93% (95% 신뢰구간, 88%-96%)이었으며 mRECIST 생존 카테고리는 56% (95% 신뢰구간, 42%-69%)와 86% (95% 신뢰구간, 72%-94%)이었다. LR-TR 생존 카테고리는 mRECIST에 비하여 유의하게 높은 특이도를 보였으나(p < 0.01) 민감도는 유사하였다(p = 0.53). 결론 LR-TR 알고리즘은 국소 치료 후 병리학적 잔존 간세포암의 진단에 대하여 민감도의 유의한 차이 없이 mRECIST보다 높은 특이도를 보였다.