• Title/Summary/Keyword: diagnostic model

Search Result 854, Processing Time 0.025 seconds

Measuring the Professional Development Needs for Technical and Vocational Education and Training Staff in Nepal: A Look at Teachers' Perceptions (네팔 직업기술교육훈련 교사들의 교육훈련 프로그램 요구조사)

  • Lim, Jin Ho;Kim, Dongwook
    • Journal of Practical Engineering Education
    • /
    • v.12 no.1
    • /
    • pp.163-176
    • /
    • 2020
  • Promoting job growth and quality has been central to developing countries to reduce poverty for decades. In this regard, Nepal is not unique in its need to develop effective TVET programme as it is considered showing positive association with workforce development and productivity. While the copious academic literature has highlighted upon staff training programme in general education, it encounters lack of adequate attention in the field of TVET education. The purpose of the study is to identity and prioritise the professional development needs for the teachers of TVET sector in Nepal. A sample(N=317) of Nepalese teachers from seven provinces were asked to answer the scale. The Borich needs assessment model was employed to assess the perceived level of importance and present preferred training modules among 29 teaching subjects. Moreover, a quadrant analysis using 2×2 matrix was used as a diagnostic tool to denote overriding training topics. The result shows that following competence skills constructs were perceived to be in high need of enhancement as well as in existence of discrepancies: 'occupational characteristics of TVET trainer', 'training needs analysis and curriculum development', 'curriculum development based on national competence standard(NCS)', and 'Institution management evaluation'.

Study on the Correlation between Patients Complaints of Dyspepsia and Stress -Through comparison between functional dyspepsia patients and nonsymptomatic chronic gastritis patients- (소화불량(消化不良)과 과심상(過心傷)의 상관성(相關性)에 대(對)한 고찰(考察) -스트레스, 기울(氣鬱), 비병증(脾病證)의 평가(評價)를 통(通)해-)

  • Kim, Jin-Sung;Yoon, Sang-Hyub;Ryu, Bong-Ha;Ryu, Ki-Won;Lee, Sang-Wook
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.306-317
    • /
    • 2004
  • Background & Object : Dyspepsia for which no organic causes are disclosed is referred to as functional dyspepsia. Functional dyspepsia is here studied in connection with a biopsychosocial model. From the aspect of individual response to external environment, in connection with stress response, functional dyspepsia is studied by both the psychology department and the internal medicine departments. The disease is taken as approachable from the aspect of internal injury due to seven emotions and stress as differentiated by Oriental medicine. Materials and Methods : Targeted at 223 patients underwent medical checks and endoscopy at Kangnam Korean Hospital, Kyunghee University. They agreed to join this clinical experiment. Stress response inventory, GARS (global assessment of recent stress scale), GSRS (gastrointestinal symptom rating scale), diagnostic scores for Ki-depression, and Spleen Disease Differentiation of Syndromes were all measured and evaluated. The test group was comprised of functional dyspepsia patients. The control group was comprised of nonsymptomatic chronic gastritis patients who were found to suffer from chronical gastritis in endoscopy and thus could be diagnosed with functional dyspepsia if symptoms would arise, but did not complain of subjective symptoms. Results showed these corelations: Functional dyspepsia patients were found to have more serious Ki-depression compared to nonsymptomatic chronic gastritis patients. The more serious Ki-depression the more serious the dyspepsia symptoms. The higher the stress response inventory the more serious the dyspepsia. Deficiency of spleen Eum, and Deficiency and Sinking of spleen Gi were found to coincide with serious Ki-depression.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

Radiation-induced Pulmonary Damage in Lung Cancer Patients (폐종양 환자에서 방사선치료에 의한 폐손상)

  • Chung, Su-Mi;Choi, Ihl-Bohng;Kong, Ki-Hun;Kim, In-Ah;Shinn, Kyung-Sub
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.321-330
    • /
    • 1993
  • Purpose: A retrospective analysis was performed to evaluate the incidence of radiation induced lung damage after the radiation therapy for the patients with carcinoma of the lung. Method and Materials: Sixty-six patients with lung cancer (squamous cell carcinoma 27, adenocarcinoma 14, large cell carcinoma 2, small cell carcinoma 13, unknown 10) were treated with definitive, postoperative or palliative radiation therapy with or without chemotherapy between July 1987 and December 1991. There were 50 males and 16 females with median age of 63 years (range: 33~80 years). Total lung doses ranged from 500 to 6,660 cGy (median 3960 cGy) given in 2 to 38 fractions (median 20) over a range or 2 to 150 days (median in days) using 6 MV or 15 MV linear accelerator. To represent different fractionation schedules of equivalent biological effect, the estimated single dose (ED) model, $ED=D{\dot}N^{-0.377}{\dot}T^{-0.058}$ was used in which D was the lung dose in cGy, N was the number of fractions, and T was the overall treatment time in days. The range of ED was 370 to 1357. The endpoint was a visible increase in lung density within the irradiated volume on chest X-ray as observed independently by three diagnostic radiologists. Patients were grouped according to ED, treatment duration, treatment modality and age, and the percent incidence of pulmonary damage for each group was determined. Result: In 40 of 66 patients, radiation induced change was seen on chest radiographs between 11 days and 314 days after initiation of radiation therapy. The incidence of radiation pneumonitis was increased according to increased ED, which was statistically significant (p=0.001). Roentgenographic changes consistent with radiation pneumonitis were seen in $100\%$ of patients receiving radiotherapy after lobectomy or pneumonectomy, which was not statistically significant. In 32 patients who also received chemotherapy, there was no difference in the incidence of radiation induced change between the group with radiation alone and the group with radiation and chemotherapy, among the sequence of chemotherapy No correlation was seen between incidence of radiation pneumonitis and age or sex. Conclusions: The occurrence of radiation pneumonitis varies. The incidence of radiation pneumonitis depends on radiation total dose, nature of fractionation, duration of therapy, and modifying factors such as lobectomy or pneumonectomy.

  • PDF

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Analysis of Patients with Hemoptysis in a Tertiary Referral Hospital

  • Lee, Bo Ram;Yu, Jin Yeong;Ban, Hee Jung;Oh, In Jae;Kim, Kyu Sik;Kwon, Yong Soo;Kim, Yu Il;Kim, Young Chul;Lim, Sung Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Background: This study attempted to investigate the main causes of hemoptysis, the type of examinations used for diagnosis, the treatment modalities and outcomes. Methods: A retrospective study was conducted on the medical records of 221 patients admitted to the Chonnam National University Hospital, between January 2005 and February 2010, with hemoptysis. Results: Bronchiectasis (32.6%), active pulmonary tuberculosis (18.5%), fungus ball (10.8%), and lung cancer (5.9%) accounted for most causes of hemoptysis. Computed tomography scan was the most sensitive diagnostic test when employed alone, with positive yield of 93.2%. There were 161 cases of conservative treatment (72.9%), 42 cases of bronchial artery embolization (BAE) (19.0%), and 18 cases of surgery (8.1%). Regarding the amount of hemoptysis, 70 cases, out of 221 cases, were mild (31.5%), 36 cases moderate (16.2%), and 115 cases massive hemoptysis (52.0%). Most of the patients were treated conservatively, but if there was more bleeding present, BAE or surgery was more commonly performed than the conservative treatment ($p{\leq}0.0001$). In the multivariate model, severe hemoptysis and lung cancer were independently associated with short-term recurrence. BAE was independently associated with long-term recurrence, and lung cancer was associated with in-hospital mortality. The overall in-hospital mortality rate was 11.3%. Conclusion: Hemoptysis is a common symptom with a good prognosis in most cases. However, patients exhibiting massive bleeding or those with malignancy had a poorer prognosis. In-hospital mortality was strongly related to the cause, especially in lung cancer.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

Analysis of Research Trends of Cyber Physical System(CPS) in the Manufacturing Industry (제조 분야 사이버 물리 시스템(CPS) 연구 동향 분석)

  • Kang, Hyung-Muck;Hwang, Kyung-Tae
    • Informatization Policy
    • /
    • v.25 no.3
    • /
    • pp.3-28
    • /
    • 2018
  • The purpose of this study is to analyze the research trends and present future research directions in the field of Cyber Physical System (CPS), a key element in the 4th Industrial Revolution, Industry 4.0, and Smart Manufacturing that are currently promoted as important innovation agenda both at home and abroad. In this study, (1) the concepts of industry 4.0, smart manufacturing and CPS are summarized; (2) analysis criteria of these fields are established; and 3) analysis results are presented and future research direction is proposed. 74 overseas and 8 domestic literature on manufacturing CPS from 2013 to 2017 are identified through 'Google Scholar Search'. Major results of the analysis are summarized as follows: (1) research on a common methodology and framework for the manufacturing CPS needs to be done based on the analysis of the existing methodologies and frameworks of various perspectives; (2) in order to improve the maturity of the manufacturing CPS, it is necessary to study actual deployment and operations of CPS, including the existing systems; (3) it is necessary to study the diagnostic methodology that can evaluate manufacturing CPS and suggest improvement strategy; and (4) as for the detailed model and tool, it is necessary to reinforce research on SCM production planning and human-machine collaboration while considering the characteristics of CPS.

Transcranial Doppler Ultrasonography(TCD) in diagnosis of Cerebrovascular Accident (CVA) (뇌졸중의 진단에 대한 TCD의 활용 (Brain CT, Brain MRI와 Transcranial Doppler Ultrasonography 비교를 통한 뇌졸중 진단의 상호 보완에 관한 연구))

  • Park, Se-Gi;Kang, Myeong-Seog;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.171-189
    • /
    • 1996
  • Background and Purpose: The greater part of patients to visit Hospital of Oriental Medicine suffer from cerebrovascular accident(CVA). There is transcranial Doppler(TCD) in the diagnostic method to confirm cerebrovascular accident(CVA). Transcranial Doppler(TCD) is an accurate method of monitoring the blood flow velocities of the cerebral vessels and have been generally used to prevent symptomatic vasospasm and confirm cerebral infarction. So we studied, in the crebrovascular accident(CVA), to estimate whether transcranial Doppler(TCD) is useful to. Methods: Using transcranial doppler(Multigon Model 500M Transcranial Doppler System), we measured the mean and peak velocity and the direction of blood flow in 10 cerebrovascular accident(CVA)'s subjects who had been examined by Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). Results : As an anticipation, in cerebrovascular accident(CVA)'s subject with Cb-infarction, the mean and peak velocity of blood flow fell down remarkably and the direction of blood flow was change or irritable. But didn't find out any signal in lacunar infarction. Also, in case with spontaneous hemorrhage, the velocity and direction of blood flow was change but this signal was short of diagnosis for Cb-hemorrhage. Besides, we found signals about embolism, stenosis, thrombosis and occlusion in cerebrovascular accident(CVA)'s subjects. Conclusion: In Cb-infarction, the result of TCD was equal to diagnosis with Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). But about lacunar infarction or spontaneous hemorrhage, signals of TCD couldn't be found out or was insufficient more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). In cerebrovascular accident(CVA)'s subject with embolism, stenosis, thrombosis or occlusion, signals of TCD were found out more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). Therefore transcranial doppler(TCD) is necessary method which makes a diagnosis of cerebrovascular accident(CVA), with Computed Tomography(CT) or Magnetic Resonance Imaging(MRI).

  • PDF