• 제목/요약/키워드: diagnostic inference

검색결과 75건 처리시간 0.023초

EXPERT KNOWLEDGE GATING MECHANISM IN THE HIERARCHICAL MODULAR SYSTEM

  • Shim, Jeong-Yon;Hong, You-Sik
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.288-291
    • /
    • 2003
  • For the purpose of building the more efficient knowledge learning system, it is very important to make a good structure of the knowledge system first of all. The well designed knowledge system can make the stored knowledge to be easily accessed for knowledge acquisition and extraction. Expert knowledge can also play a good role for controlling. Accordingly, in this paper we propose the Hierarchical modular system with expert knowledge gating mechanism. This system consists of the mechanisms for knowledge acquisition, constructing the associative memory, knowledge inference and extraction according to the expert knowledge gating mechanism. We applied this system to the medical diagnostic area for classifying Virus(coxackie virus, echovirus, cold), Rhinitis(Nonallergic, allergic) and tested with symptom data

  • PDF

EXPERT SYSTEM FOR A NUCLEAR POWER PLANT ACCIDENT DIAGNOSIS USING A FUZZY INFERENCE METHOD

  • Lee, Mal-Rey;Oh, Jong-Chul
    • Journal of applied mathematics & informatics
    • /
    • 제8권2호
    • /
    • pp.505-518
    • /
    • 2001
  • The huge and complicated plants such as nuclear power stations are likely to cause the operators to make mistakes due to a variety of inexplicable reasons and symptoms in case of emergency. That’s why the prevention system assisting the operators is being developed for. First of all. I suggest an improved fuzzy diagnosis. Secondly, I want to demonstrate that a classification system of nuclear plant’s accident investigating the causes of accidents foresees possible problems, and maintains the reliability of the diagnostic reports in spite of improper working in part. In the event of emergency in a nuclear plant, a lot of operational steps enable the operators to find out what caused the problems based on an emergent operating plan. Our system is able to classify their types within twenty to thirty seconds. As so, we expect the system to put down the accidents right after the rapid detection of the damage control-method concerned.

수면 장애 환자를 통한 『상한론 (傷寒論)』 음양역차후노복병(陰陽易差後勞復病)에 대한 고찰과 DSM-5 수면-각성 장애와의 연관성 (Analyzing Eumyangyeokchahunobok -byung(陰陽易差後勞復病) based on cases report and its association with DSM-5 sleep-wake disorder)

  • 최운용;이성준
    • 대한상한금궤의학회지
    • /
    • 제11권1호
    • /
    • pp.153-167
    • /
    • 2019
  • Objective : To explore the meaning of Eumyangyeokchahunobok-byung (陰陽易差後勞復病) through two cases and finding the relationship with the DSM-5 sleep-wake disorder. Methods : Following a disease pattern identification diagnostic system based on Shanghanlun provisions (DPIDS), we analyzed cases with chronic fatigue and diplopia caused after sleep disorders. The patients were treated with the Soshiho-tang and Yijoong-tang. Results : The two herbal medicines showed remarkable improvement in the patients. The sleep disorders and the secondary pathologies were rapidly relieved within a month. Conclusions : The patterns of sleep disorders of the two patients were found to be very similar to the circadian rhythm sleep-wake disorders, as described in DSM-5. Although the etymology of the Chinese characters has not been clearly known yet, it was possible to present the original hypotheses on 更and 了due to clinical inference.

FTA(Falut tree Analysis)기법을 이용한 이송용 로울러베어링 고장 진단

  • 배용환;이석희;이형국;최진원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.325-329
    • /
    • 1992
  • The development of automatic production system have required intelligent diagnostic and monitoring function to repair system failure and reduce production loss by the failure. In order to perform accurate functions of intelligent system, inference about total system failure and fault analysis due to each mechanical component failures are required. Also the solution about repair and maintenance can be suggested from these analysis results. Generally, bearing is a essential mechanical component in the machinery. The bearing failure is caused by lubricant system failure, metallurgical defficiency, mechanical condition(vibration overloading misalignment), environmental effect. This study described roller bearing fault train due to stress variation and metallurgical defficiency from lubricant failure by using FTA.

냉동기 성능 진단을 위한 적응형 뉴로퍼지(ANFIS) 모델 개발 (Prediction of Vapor-Compressed Chiller Performance Using ANFIS Model)

  • 신영기;장영수;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.89-95
    • /
    • 2001
  • On-site diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for the purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

  • PDF

공작기계용 원격 고장진단 및 보수 시스템 (Remote Fault Diagnosis and Maintenance System for NC Machine Tools)

  • 신동수;현웅근;정성종
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.19-25
    • /
    • 1998
  • Remote fault diagnosis and maintenance system using general telecommunication network is necessary for an effective fault diagnosis and higher productivity of NC machine tools. In order to monitor machine tool condition and diagnose alarm states due to electrical and mechanical faults, a remote data communication system for monitoring of NC machine fault diagnosis and status is developed. The developed system consists of (1) remote communication module among NC's and host PC using PSTN. (2) 8 channels analog data sensing module, (3) digital I/O module for control or NC machine, (4) communication module between NC machine and remote data communication system via RS-232C, and (5) software man-machine interface. Diagnostic monitoring results generated through a successive type inference engine are displayed in user-friendly graphics. The validity and reliability of the developed system is verified to be a powerful commercial version on a vertical machining center through a series of experiments.

  • PDF

The Bivariate Kumaraswamy Weibull regression model: a complete classical and Bayesian analysis

  • Fachini-Gomes, Juliana B.;Ortega, Edwin M.M.;Cordeiro, Gauss M.;Suzuki, Adriano K.
    • Communications for Statistical Applications and Methods
    • /
    • 제25권5호
    • /
    • pp.523-544
    • /
    • 2018
  • Bivariate distributions play a fundamental role in survival and reliability studies. We consider a regression model for bivariate survival times under right-censored based on the bivariate Kumaraswamy Weibull (Cordeiro et al., Journal of the Franklin Institute, 347, 1399-1429, 2010) distribution to model the dependence of bivariate survival data. We describe some structural properties of the marginal distributions. The method of maximum likelihood and a Bayesian procedure are adopted to estimate the model parameters. We use diagnostic measures based on the local influence and Bayesian case influence diagnostics to detect influential observations in the new model. We also show that the estimates in the bivariate Kumaraswamy Weibull regression model are robust to deal with the presence of outliers in the data. In addition, we use some measures of goodness-of-fit to evaluate the bivariate Kumaraswamy Weibull regression model. The methodology is illustrated by means of a real lifetime data set for kidney patients.

퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선 (Performance Improvement of MOS type FDIS using Fuzzy Logic)

  • 류지수;박태건;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.410-413
    • /
    • 1998
  • A passive approach for enhancing fault detection and isolation performance of multiple observer based fault detection isolation schemes(FDIS) is proposed. The FDIS has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises of a rule base and fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic and threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rule base. The suggested scheme is applied for the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

Bio-inspired self powered nervous system for civil structures

  • Shoureshi, Rahmat A.;Lim, Sun W.
    • Smart Structures and Systems
    • /
    • 제5권2호
    • /
    • pp.139-152
    • /
    • 2009
  • Globally, civil infrastructures are deteriorating at an alarming rate caused by overuse, overloading, aging, damage or failure due to natural or man-made hazards. With such a vast network of deteriorating infrastructure, there is a growing interest in continuous monitoring technologies. In order to provide a true distributed sensor and control system for civil structures, we are developing a Structural Nervous System that mimics key attributes of a human nervous system. This nervous system is made up of building blocks that are designed based on mechanoreceptors as a fundamentally new approach for the development of a structural health monitoring and diagnostic system that utilizes the recently developed piezo-fibers capable of sensing and actuation. In particular, our research has been focused on producing a sensory nervous system for civil structures by using piezo-fibers as sensory receptors, nerve fibers, neuronal pools, and spinocervical tract to the nodal and central processing units. This paper presents up to date results of our research, including the design and analysis of the structural nervous system.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.