• Title/Summary/Keyword: diagnosis & evaluation system

Search Result 566, Processing Time 0.025 seconds

A Case Report of Severe Femoral Neuropathy with Motor Weakness and Hypoesthesia Treated by Combined Western-Korean Medicine Treatment (근력저하 및 감각저하를 호소하는 중증 대퇴신경병증 환자에 대한 양⋅한방 병용 치료 1례)

  • So-min Jung;Seon-uk Jeon;Moon-young Ki;Ye-chae Hwang;Gyeongmuk Kim;Han-Gyul Lee;Sang-Kwan Moon;Woo-Sang Jung;Seungwon Kwon
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.176-189
    • /
    • 2024
  • In femoral neuropathy, the femoral nerve is compressed or ischemic. Patients with femoral neuropathy experience muscle atrophy, difficulty flexing the hip joint and extending the knee, decreased sensation of the lower extremities, and loss of patellar tendon reflex. The prognosis of femoral neuropathy is reported to vary, as it takes several days to several months for neurological abnormalities to resolve. We describe a case of a 58-year-old female with a diagnosis of severe femoral neuropathy and complaints of motor weakness and hypoesthesia. The patient underwent combined Western-Korean medicine treatment. The Toronto Clinical Neuropathy Scoring System, Overall Neuropathy Limitations Scale, and Berg Balance Scale were used as evaluation tools during the treatment period. The combined Western-Korean medicine treatment led to a significant improvement in symptoms in this patient with severe femoral neuropathy where the cause was unclear and the prognosis was expected to be poor.

Review of Allowable Condition of the Discretionary not Covered Service (임의비급여 허용요건에 관한 검토)

  • Park, Tae-Shin
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.2
    • /
    • pp.11-38
    • /
    • 2012
  • The Supreme Court stand in the position in specific lawsuit that it doesn't allow the discretionary not covered service, but recently in revocation suit of fine disposal that is imposed on medical fee of leukemia patient, it altered the existing adjudgement and admitted the discretionary not covered service exceptionally. It put forward the allowable condition roughly in that case. According as this alteration, it has become more important to embody the allowance conditions of exceptions. The Supreme Court presented three things, which are procedural condition, medical condition and subscriber's agreement. Concerning procedural condition, several present conciliation procedures are as follows: medical care benefit arret request, relative value conciliation etc, prior request on anti-cancer drug among chemicals which exceed acceptance criteria, request of non benefit object on common drugs. To be granted the existence of those system, there should be no obstacle to use that. Even if it were so, we should take circumstances into consideration; individual situation is unescapable concerning substance and urgency of the discretionary not covered service, process of the procedure, time required etc. Regarding medical condition, safety and effectiveness will be verified through evaluation procedures of new medical skill. About the necessity, the Supreme Court made clear through a sentence that it allow the discretionary not covered service, in case that needs to treat a patient out of the standard of medical benefit. Strict interpretation is right and it answer the purpose of the sentence that the supreme court permit the discretionary not covered service, exceptionally. We need to differentiate medical necessity and medical validity. Subscriber's agreement should holds true if it entails full explanation, and if it is preliminary, explicit and individual. On this account, it should be difficult to admit that someone agree effectively when he call for the affirmation that he is recipient of medical care. Reasonable expense needs to be a part of review whether the agreement is valid. Meanwhile If we adjust system of medical expense and eventually reorganize a fee for consultation payment system (Fee-for-service controlled by item to DRG (Diagnosis Related Groups)), controversial area of the discretionary not covered service will be decreased and that will guarantee the discretion of the doctor.

  • PDF

Implementation and Evaluation of Electroglottograph System (전기성문전도(EGG) 시스템의 개발 및 평가)

  • 김기련;김광년;왕수건;허승덕;이승훈;전계록;최병철;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2004
  • Electroglottograph(EGG) is a signal recorded from the vocal cord vibration by measuring electrical impedance across the vocal folds through the neck skin. The purpose of this study was to develop EGG system and to evaluate possibility for the application on speech analysis and laryngeal disease diagnosis. EGG system was composed of two pairs of ring electrodes, tuned amplifier, phase sensitive detector, low pass filter, and auto-gain controller. It was designed to extract electric impedance after detecting by amplitude modulation method with 2.7MHz carrier signal. Extracted signals were transmitted through line-in of PC sound card, sampled and quantized. Closed Quotient(CQ), Speed Quotient(SQ), Speed Index(SI), fundamental frequency of vocal cord vibration(F0), pitch variability of vocal fold vibration (Jitter), and peak-to-peak amplitude variability of vocal fold vibration(Shimmer) were analyzed as EGG parameters. Experimental results were as follows: the faster vocal fold vibration, the higher values in CQ parameter and the lower values in SQ and SI parameters. EGG and speech signals had the same fundamental frequency. CQ, SQ, and SI were significantly different between normal subjects and patients with laryngeal cancer. These results suggest that it is possible to implement portable EGG system to monitor the function of vocal cord and to test functional changes of the glottis.

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF

A Study on Intelligent Skin Image Identification From Social media big data

  • Kim, Hyung-Hoon;Cho, Jeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.9
    • /
    • pp.191-203
    • /
    • 2022
  • In this paper, we developed a system that intelligently identifies skin image data from big data collected from social media Instagram and extracts standardized skin sample data for skin condition diagnosis and management. The system proposed in this paper consists of big data collection and analysis stage, skin image analysis stage, training data preparation stage, artificial neural network training stage, and skin image identification stage. In the big data collection and analysis stage, big data is collected from Instagram and image information for skin condition diagnosis and management is stored as an analysis result. In the skin image analysis stage, the evaluation and analysis results of the skin image are obtained using a traditional image processing technique. In the training data preparation stage, the training data were prepared by extracting the skin sample data from the skin image analysis result. And in the artificial neural network training stage, an artificial neural network AnnSampleSkin that intelligently predicts the skin image type using this training data was built up, and the model was completed through training. In the skin image identification step, skin samples are extracted from images collected from social media, and the image type prediction results of the trained artificial neural network AnnSampleSkin are integrated to intelligently identify the final skin image type. The skin image identification method proposed in this paper shows explain high skin image identification accuracy of about 92% or more, and can provide standardized skin sample image big data. The extracted skin sample set is expected to be used as standardized skin image data that is very efficient and useful for diagnosing and managing skin conditions.

Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study (팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가)

  • Bahn, Young-Kag;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.53-59
    • /
    • 2011
  • Purpose: To evaluate the dosimetry and image of very low does CT attenuation correction for phantom using pediatric PET/CT. Materials and methods: three PET / CT scanners (Discovery STe, BiographTruepoint 40, Discovery 600) as a child-size acrylic phantom and ion chamber dosimeter (Unfous Xi CT, Sweden) using a CT image acquisition parameters (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp) by varying the depth dose and evaluate $CTDI_{vol}$ value. And each attenuation corrected PET/CT images used NEMA PET Phantom$^{TM}$ (NU2-1994) was evaluated by SUV. Results: Abdominal diagnosis CT dose in general pediatric (about 10 ages) parameter (100 kVp, 100 mA) than very low dose CT parameter (80 kVp, 10 mA) at the depth dose was reduced approximately 92%, $CTDI_{vol}$ was reduced to about 88%. Each CT attenuation corrected parameters PET images showed no change in the value of SUV. Conclusion: for pediatric patients, PET/CT scan can be obtained with very low dose attenuation correction CT (80 kVp, 10 mA), and such attenuation correction CT dose was reduced 100 fold than diagnosis CT dose. PET / CT scan used very low dose CT attenuation correction in pediatric patients can be helpful in reducing radiation dose.

  • PDF

Usefulness of a Alvarado Scoring System for the Diagnosis of Acute Appendicitis in Children (소아 충수돌기염 진단에서 Alvarado Scoring System의 유용성)

  • Yang, Eun Seok;Yoon, Sung Kwan;Kim, Eun Young;Rho, Young Il;Park, Sang Kee;Park, Yeong Bong;Mun, Gyeong-Rae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • Purpose: Alvarado scoring system was evaluated regarding its usefulness for the early diagnosis of acute appendicitis in adult and in reduction of the incidence of negative appendicectomies. To evaluate the accuracy of diagnosing appendicitis using the Alvarado score in children. Methods: Prospectively, we surveyed 122 patients (male 67, female 55) suffering from abdominal pain, who had visited to the emergency department of Chosun University Hospital from June 2002 to May 2003. The Alvarado score has been computed from the white blood cell count, neutrophil count, body temperature, resistance in the right lower quadrant, length of symptoms, nausea and vomiting. Each patient was evaluated by a pediatric resident and then by a general surgeon independently. Results: Out of 170 total children who visited to the emergency department due to abdominal pain, 122 patients were associated with appendicitis. A total of 122 patients (67 male and 55 female) were visited to the emergency room with suspected appendicitis. From 105 operated patients, 92 (87.6%) were diagnosed acute appendicitis and erronous diagnostic rate was 12.4%, pathologically. Mean alvarado score of appendicitis group was $5.40{\pm}1.24$ whereas those of non-appendicitis group was $3.73{\pm}1.82$ (p<0.05). From 6 Alvarado score high sensitivity (86.4%) and high specificity (80.0%) were observed. Sensitivity of ultrasonography or computed tomography was 92.5%. Conclusion: We found that Alvarado score system is a noninvasive, safe diagnostic method, which is simple, reliable and repeatable. Alvarado score is useful system for a first, rapid and economic evaluation for the appendicitis in children.

  • PDF

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Dental anomalies associated with Axenfeld-Rieger syndrome (Axenfeld-Rieger 증후군과 연관된 치과적 이상)

  • Kim, Ki-Rim;Lee, Doo-Young;Kim, Seung-Hye;Lee, Sang-Hui;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.6 no.2
    • /
    • pp.94-98
    • /
    • 2010
  • Axenfeld-Rieger syndrome is a rare autosomal dominant disorder characterized by various ocular and extraocular malformations. The incidence of Axenfeld-Rieger syndrome has been estimated to be 1 per 200,000. The syndrome is characterized by short body stature, delayed bone age, and deficient or arrested development of neural crest cells involving the anterior chamber of the eyes, facial bones, teeth, periumbilical skin, and cardiovascular system. This is a case of a 6 year-old girl, who came to the department of the pediatric dentistry, Yonsei University Dental Hospital, for evaluation and treatment of multiple congenital missing permanent teeth. The patient presented typical dental, craniofacial, and systemic features of Axenfeld-Rieger syndrome, such as glaucoma, oval pupil, heterochromatic iris, umbilical hernia, and delayed bone age. On the panoramic view, 3 primary teeth were missing and 13 permanent tooth germs were absent. On the lateral cephalograph, underdevelopment of the maxilla and normal growth pattern of the mandible were confirmed. Periodic dental follow-up is planned for evaluation and interceptive treatment of her dental and craniofacial problems. Denture or removable space maintainer with a pontic is considered for esthetic and functional restoration. In addition, orthognathic surgery is also planned in future to prevent further midfacial skeletal deformation. Early diagnosis of Axenfeld-Rieger syndrome is very important to prevent exacerbation of complications, such as glaucoma and skeletal deformities.

  • PDF