• Title/Summary/Keyword: diagnosis & evaluation system

Search Result 563, Processing Time 0.033 seconds

Development of Black Box for EV Charging Infra based on Solar Power Generation and ESS (태양광발전 및 ESS 기반 전기차 충전인프라용 블랙박스 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.160-167
    • /
    • 2018
  • In this paper, a black box, which is provided the reliability and user safety of home battery energy storage system connected with solar energy generation, is developed. In the developed scheme, a status and diagnosis data of battery management system, power conditioning system, solar energy generation and grid is measured. This status and diagnosis data is stored and displayed in the developed black box. In addition, this status and diagnosis data is stored and displayed in a monitoring system and a smart phone of user. A performance evaluation of the developed black box is carried out using emulator of home battery energy storage system connected with solar energy generation. Consequently, the developed black box is proved its superiority of the reliability and user safety.

A Study on Enhancing Efficiency of the Safety Certification and Diagnosis System for Buildings (건축물의 안전성 관련 인증 및 진단 제도의 효율성 제고를 위한 연구)

  • Sang-Pil Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.73-78
    • /
    • 2023
  • It is very important to evaluate how the functions of products, facilities, and spaces affect human life. The evaluation of these actions has legal regulations such as certification, inspection, and diagnosis, and the degree of quality, safety, and excellence of the results is announced. This study sought to secure safety through efficient system operation by reviewing safety-related certification systems established and implemented by each government department in Korea and analyzing the characteristics of each system and similarities between systems. There was also an aspect of cross-checking safety through the certification and diagnosis system implemented by each ministry, but it was confirmed that the efficiency of the system should also be considered in terms of overlapping application. Therefore, when securing safety is confirmed based on each safety-related law, active alternatives such as exemption, substitution, delegation, etc. should be presented.

Estimation of National Loss Expenses to Insufficient Safety Inspection and Precision Safety Diagnosis (부실 정밀점검 및 정밀안전진단의 국가적 손실비용 추정)

  • Ha, Myung-Ho;Park, Jong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.246-253
    • /
    • 2010
  • National major facilities have been rigorously investigated using regular safety inspections and precision safety diagnosis since the Special Law for Facilities Safety Management was made in 1995. However, the process of safety inspection and precision safety diagnosis could be doubted due to intervention of facility owner for safety level evaluation, competition to obtain low price order, and low technical skills of inspection companies. Although the management processes for evaluating the inspection companies were used for several years, the process should continue to improve in the safety inspection field. This study analyzed the recent evaluation system and the ratios of insufficient inspection. Estimation of national loss expenses to the insufficient safety inspection was investigated to recognize the necessity for the improvement of facility inspection process and evaluation system.

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

A study on Improvement of Web-based Diagnosis-Supplement System for Basic Academic Skills (웹 기반 기초학력 진단-보정 시스템의 개선 방안 도출)

  • Jeon, Soo-Jin;Kim, Han-Sung
    • Journal of The Korean Association of Information Education
    • /
    • v.20 no.5
    • /
    • pp.487-498
    • /
    • 2016
  • The Ministry of Education has serviced nationwide the diagnosis-supplement system for basic academic skills for elementary and middle schools since 2013. The purpose of this paper is to propose an improvement plans of the diagnosis-supplement system by analysing system utilization status, 2015 and requirements of teachers and experts. For this study, over three times the taking rates and achievement rates were analyzed and the interviews and consultations of teachers and professionals were also analyzed. In conclusion, we proposed the improvement plans of the diagnosis-supplement system for the each of teachers and students.

Development of Diagnosis Application for Rail Surface Damage using Image Analysis Techniques (이미지 분석기법을 이용한 레일표면손상 진단애플리케이션 개발)

  • Jung-Youl Choi;Dae-Hui Ahn;Tae-Jun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.511-516
    • /
    • 2024
  • The recently enacted detailed guidelines on the performance evaluation of track facilities presented the necessary requirements regarding the evaluation procedures and implementation methods of track performance evaluation. However, the grade of rail surface damage is determined by external inspection (visual inspection), and there is no choice but to rely only on qualitative evaluation based on the subjective judgment of the inspector. Therefore, in this study, we attempted to develop a diagnostic application that can diagnose rail internal defects using rail surface damage. In the field investigation, rail surface damage was investigated and patterns were analyzed. Additionally, in the indoor test, SEM testing was used to construct image data of rail internal damage, and crack length, depth, and angle were quantified. In this study, a deep learning model (Fast R-CNN) using image data constructed from field surveys and indoor tests was applied to the application. A rail surface damage diagnosis application (App) using a deep learning model that can be used on smart devices was developed. We developed a smart diagnosis system for rail surface damage that can be used in future track diagnosis and performance evaluation work.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Diagnosis of Performance Measurement System of Knowledge Management : A Case of University (대학 지식경영 성과측정시스템의 진단 사례연구)

  • Lee, Young-Chan;Lee, Seung-Seok
    • Knowledge Management Research
    • /
    • v.10 no.1
    • /
    • pp.71-100
    • /
    • 2009
  • Recently, many of organizations build up their performance measurement system (PMS) to measure their knowledge management performance. However, the system that doesn't well reflect the organization's strategies as well as surroundings could obstruct their performance improvement, instead. Therefore, It is really important to establish the PMS to reflect organization's surroundings and strategies. The purpose of this study is to make a diagnosis of a performance measurement practice of a domestic university's knowledge management. To serve this research purpose, we examine the uptight performance index and PMS from existing references. And we diagnose the specific practices and maturity rates of measuring performances, and the recognition of the performance index at "D" university recently adopting balanced scorecard to performance evaluation through the survey on academic affairs committee members, performance evaluation committee members, and administration members. The method analyzing data from the survey is a gap analysis which includes alignment analysis, congruence analysis, consensus analysis, and confusion analysis. We make a diagnosis of performance measurement practices at "D" university, raise several points of this performance measurement system, and present the improvement plans from these problems.

  • PDF

Development of Inspection and Diagnosis System for Safety and Maintenance in Tunnel (터널 유지관리를 위한 안전진단시스템 개발에 관한 연구)

  • Kim, Young-Geun;Baek, Ki-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Recently, as tunnel structure is getting old, many deformations and defects have been occurred. As tunnel has the characteristics of underground structure, the estimation of the cause of deformation is very difficult. Then, it is necessary to investigate the state of tunnel lining and to estimate the deformation cause and safety for tunnel. In this study, inspection and diagnosis system for effective maintenance in tunnel was researched. Firstly, non-destructive techniques such as GPR (ground penetrating radar), impact echo test, and infrared thermal techniques were applied to tunnel lining inspection. Tunnel lining analysis system was developed to analyze the stability of tunnel. And, tunnel soundness evaluation system was developed to find the probable causes and indicate the method for repair and reinforcement for tunnel.

  • PDF