• Title/Summary/Keyword: devices

Search Result 24,765, Processing Time 0.047 seconds

A Study on the Security Threats of IoT Devices Exposed in Search Engine (검색엔진에 노출된 IoT 장치의 보안 위협에 대한 연구)

  • Han, Kyong-Ho;Lee, Seong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.128-134
    • /
    • 2016
  • IoT devices including smart devices are connected with internet, thus they have security threats everytime. Particularly, IoT devices are composed of low performance MCU and small-capacity memory because they are miniaturized, so they are likely to be exposed to various security threats like DoS attacks. In addition, in case of IoT devices installed for a remote place, it's not easy for users to control continuously them and to install immediately security patch for them. For most of IoT devices connected directly with internet under user's intention, devices exposed to outside by setting IoT gateway, and devices exposed to outside by the DMZ function or Port Forwarding function of router, specific protocol for IoT services was used and the devices show a response when services about related protocol are required from outside. From internet search engine for IoT devices, IP addresses are inspected on the basis of protocol mainly used for IoT devices and then IP addresses showing a response are maintained as database, so that users can utilize related information. Specially, IoT devices using HTTP and HTTPS protocol, which are used at usual web server, are easily searched at usual search engines like Google as well as search engine for the sole IoT devices. Ill-intentioned attackers get the IP addresses of vulnerable devices from search engine and try to attack the devices. The purpose of this study is to find the problems arisen when HTTP, HTTPS, CoAP, SOAP, and RestFUL protocols used for IoT devices are detected by search engine and are maintained as database, and to seek the solution for the problems. In particular, when the user ID and password of IoT devices set by manufacturing factory are still same or the already known vulnerabilities of IoT devices are not patched, the dangerousness of the IoT devices and its related solution were found in this study.

Cost Comparison of FACTS Devices and Conventional Transmission Devices (FACTS 송전 설비와 기존 송전 설비의 경제성 비교)

  • Choi, Joon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.308-310
    • /
    • 1998
  • In this paper, cost of FACTS devices and that of conventional 345kV transmission devices that transmit scheduled amount of electricity from one point to other point for thirty years is calculated and compared to each other. In case of long distant transmission, cost of FACTS devices is smaller compared to that of conventional 345kV transmission devices, and in case of short distant transmission cost of FACTS devices is bigger than that of conventional transmission devices.

  • PDF

The Effects of Infant's Digital Device Usage and Parents' Perception on Infant's Language Development (영아의 디지털기기 사용과 디지털기기에 대한 부모의 인식이 영아의 언어발달에 미치는 영향)

  • Kim, Yooeun;Kim, Jeongwha
    • Korean Journal of Childcare and Education
    • /
    • v.16 no.3
    • /
    • pp.39-58
    • /
    • 2020
  • Objective: The purpose of this study is to investigate the effects of parents' perception of infant's use of digital devices on language development. Methods: For this study, a survey was conducted on 285 parents of 1-2year old infants attending childcare centers in Jeollanam-do. Results: First, the digital devices that infants were exposed to the most was the television, and their first exposure to digital devices was at 13~17 months. The most time spent using digital devices was 30 minutes and they most frequently used them at home. Second, parents perceived the educational value of digital devices as low. Third, language development was high when the initial use of digital devices for infants was late, when the daily use time of digital devices was less than 30 minutes, when digital devices were used with parents, and when parents always managed digital devices and usage time. Fourth, Parents' perception of the use of digital devices has a significant influence on their infants' language development. Conclusion/Implications: Language development due to the use of digital devices and parents' perception of the use of digital devices has a significant impact on infants language development.

Growth of Large Area BSTO Thin Films using Pulsed Laser Deposition (펄스레이저 증착법을 이용한 대면적 BSTO 박막의 성장)

  • Kang, Dae-Won;Kwak, Min-Hwan;Kang, Seong-Beom;Paek, Mun-Cheol;Choi, Sang-Kuk;Kim, Sung-Il;Ryu, Han-Cheol;Kim, Ji-Seon;Jeong, Se-Young;Chung, Dong-Chul;Kang, Kwang-Yong;Lee, Beong-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.249-249
    • /
    • 2009
  • We have grown large area BSTO($(Ba_{1-x}Sr_x)TiO_3$) thin films (x=0.4) on 2 inch diameter MgO (001) single crystal substrates using a pulse laser deposition(PLD) system. Substrate temperature and oxygen pressure in the deposition chamber, and the laser optics for ablating a target have been controlled to obtain the uniform thickness and preferred orientation of the films. Results of x-ray diffraction and rocking curve analysis revealed that the BSTO films were grown on MgO substrates with a preferred orientation (002), and the full width half maximum of the rocking curve was measured to be 0.86 degree at optimum condition. Roughness of the films have been measured to be $3.42{\AA}$ rms by using atomic force microscopy. We have successfully deposited the large area BSTO thin films of $4000{\AA}$ thickness on 50 mm diameter MgO substrates.

  • PDF

Survey of Demand for Medical Devices in Korean Medicine (한방의료기기 개발 수요에 대한 조사연구)

  • Kim, Ji Hye;Kim, Keun Ho;Kim, Jaeuk U.
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.103-115
    • /
    • 2014
  • Objectives: The purpose of this survey was to investigate the need for new medical devices based on opinions of members of the Korean medical society. Methods: We distributed two independent questionnaires sequentially over two-week intervals to 16,510 doctors via the Korean Medical Society, and received replies from 888 and 928 doctors, respectively. The survey was carried out through a web-based questionnaire system. The first questionnaire focused on demand for new diagnostic and therapeutic medical devices that are specific for Korean medicine (KM). In contrast, the second questionnaire focused on demand for new hybrid medical devices which are useful both in Western medicine (WM) and KM. Results: In purchase intention of Korean medical devices (KMDs), demand for diagnostic devices was greater than for therapeutic ones. Among diagnostic devices, the purchase intention of 'imaging devices' ranked the highest and was followed by 'musculoskeletal diagnostic devices'. Among therapeutic KMDs, the purchase intention of 'musculoskeletal treatment devices' ranked the highest, followed by 'cranial nerve rehabilitation devices'. In the purchase intention of hybrid medical devices that can be used both in WM and KM, 'ultrasonic-based medical device' ranked the highest, followed by 'MRI-based medical device'. Conclusions: There is increasing demand for clinically useful medical devices among Korean medical doctors. Within demand for new devices, hybrid devices that can be used in both WM and KM were most strongly desired. This survey will be useful in establishing strategic plans for the development of medical devices in KM. Keywords: Korean medicine, medical device, demand survey, questionnaire.

Research of Developing of Standards for Electronic Thermometers (전자식체온계 기준규격 개발 연구)

  • Kim, E.J.;Lee, M.J.;Lee, B.Y.;Park, K.G.;Kim, D.S.;Lee, I.S.;Park, H.D.;Jeong, H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.

Parametric study for buildings with combined displacement-dependent and velocity-dependent energy dissipation devices

  • Pong, W.S.;Tsai, C.S.;Chen, Ching-Shyang;Chen, Kuei-Chi
    • Structural Engineering and Mechanics
    • /
    • v.14 no.1
    • /
    • pp.85-98
    • /
    • 2002
  • The use of supplemental damping to dissipate seismic energy is one of the most economical and effective ways to mitigate the effects of earthquakes on structures. Both displacement-dependent and velocity-dependent devices dissipate earthquake-induced energy effectively. Combining displacement-dependent and velocity-dependent devices for seismic mitigation of structures minimizes the shortcomings of individual dampers, and is the most economical solution for seismic mitigation. However, there are few publications related to the optimum distributions of combined devices in a multiple-bay frame building. In this paper, the effectiveness of a building consisting of multiple bags equipped with combined displacement-dependent and velocity-dependent devices is investigated. A four-story building with six bays was selected as an example to examine the efficiency of the proposed combination methods. The parametric study shows that appropriate arrangements of different kinds of devices make the devices more efficient and economical.

Analysis of Security Vulnerabilities for IoT Devices

  • Kim, Hee-Hyun;Yoo, Jinho
    • Journal of Information Processing Systems
    • /
    • v.18 no.4
    • /
    • pp.489-499
    • /
    • 2022
  • Recently, the number of Internet of Things (IoT) devices has been increasing exponentially. These IoT devices are directly connected to the internet to exchange information. IoT devices are becoming smaller and lighter. However, security measures are not taken in a timely manner compared to the security vulnerabilities of IoT devices. This is often the case when the security patches cannot be applied to the device because the security patches are not adequately applied or there is no patch function. Thus, security vulnerabilities continue to exist, and security incidents continue to increase. In this study, we classified and analyzed the most common security vulnerabilities for IoT devices and identify the essential vulnerabilities of IoT devices that should be considered for security when producing IoT devices. This paper will contribute to reducing the occurrence of security vulnerabilities in companies that produce IoT devices. Additionally, companies can identify vulnerabilities that frequently occur in IoT devices and take preemptive measures.

Study of Medical Devices in Traditional Korean Medical Clinics (한방의료기관 의료기기 보유 현황에 대한 조사 연구)

  • Bak, Yo-Han;Huang, Dae-Sun;Kwon, Jin-Wan;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.32 no.2
    • /
    • pp.79-91
    • /
    • 2011
  • Objectives: The purpose was to study the market of traditional Korean medical devices and survey, list and number medical devices in traditional Korean medical clinics. Methods: we researched in three ways. 1. We investigated the list of devices regarded as traditional Korean medical devices in 'Report on production, export, and import of medical devices.' 2. We investigated the statistics of medical devices equipped in traditional Korean medical clinics through the website of the Health Insurance Review & Assessment Service. 3. We surveyed medical devices in traditional Korean medical clinics by mail. Results: 1. We could not directly investigate the market for traditional Korean medical devices because they were not categorized as such ('traditional Korean medical devices'). 2. The number of medical devices in traditional Korean medical clinics has increased alongside the increase of traditional Korean medical clinics. 3. Traditional Korean medical clinics hold over 64,962 medical devices and have below 50 percent of traditional Korean medical diagnosis devices. 4. Meridian function testing machines, pulse diagnosis devices, and yangdorak showed ranking of equipment-ratio equal to ranking of insurance fees. Conclusions: Traditional Korean medical device regulations should be enacted following definitive and concrete Korean traditional medical concepts by the Korean traditional medical society.