Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권3호
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

4-D 전산모사 기법을 이용한 호전형 컴프턴 카메라의 영상 특성 평가 (Image Quality of a Rotating Compton Camera Evaluated by Using 4-D Monte Carlo Simulation Technique)

  • 서희;이세형;박진형;김찬형;박성호;이주한;이춘식;이재성
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.107-114
    • /
    • 2009
  • 컴프턴 카메라는 컴프턴 산란 현상에 기반을 둔 감마선 영상장치로 기존의 영상장치가 가지는 여러 가지 한계점들을 극복할 수 있어서 차세대 영상장치로 관심을 받고 있다. 본 연구에서는 4-D 전산모사 기법을 이용하여 회전형 컴프턴 카메라의 영상 특성을 평가하였으나, 원자력 산업용으로 활용될 수 있는 컴프턴 카메라에 대하여 가능성을 확인하여 보았다. 고정된 시스템 보다는 선원 주위를 회전하여 영상을 획득할 경우 선원의 위치 및 분포를 상대적으로 정확하게 결정할 수 있음을 확인하였다. 또한, 컴프턴 카메라의 3차원 영상가능을 통해 대형 원자력 시설해체 시 콘크리트 벽안에 존재하는 방사화된 철근구조의 위치 및 분포를 한 쪽 벽면에서 정확히 결정할 수 있음을 확인하였다. 본 연구에서 활용한 4-D 전산모사 기법은 컴프턴 카메라 분야에 최초로 적용된 기술이며, 이는 움직이는 장기 및 LINAC 켄트리, 4-D CT 등 동적 구조에 대한 모델링이 가능하므로 다양한 응용분야에서 활용될 수 있을 것으로 기대한다.

Chromite 물질의 자기상호작용에 관한 뫼스바우어 분광연구 (Mössbauer Studies of Changed Interaction on Cr Ions in Chromite)

  • 최강룡;김철성
    • 한국자기학회지
    • /
    • 제17권1호
    • /
    • pp.47-50
    • /
    • 2007
  • 최근 geometrical frustration 현상 및 멀티페로익 효과가 Cr 이온의 나선 스핀 구조에 기인하는 것으로 해석되고 있다. 이에 본 연구에서는 Cr 이온 자리에 Fe을 치환하여 $CoCrFeO_4$를 제조하였고, $M\"{o}ssbauer$ 분광법에 의해 자기적 미세 구조의 상관관계를 연구하였다. 졸겔법을 이용하여 Fd3m의 cubic 스피넬 구조를 갖는 $CoCr_2O_4,\;CoCrFeO_4$ 단일상을 합성하였고, Rietveld 법에 의한 분석결과 격자상수는 $a_0=8.340$에서 $8.377{\AA}$로 증가 하였으며, Cr, Fe 이온은 모두 팔면체 구조에 위치하는 것으로 분석되었다. 자기 상전이 온도는 $T_N=97K$에서 320 K로 증가하였으며, 상호작용의 변화에 따라서 field cooled 온도에 따른 자화 곡선의 변화를 관측하였다. $M\"{o}ssbauer$ 스펙트럼 분석결과 4.2 K에서 공명흡수선에 대한 초미세자기장($H_{hf}$) 값은 각각 507, 492 kOe 정도로 나타났으며, 이성질체 이동치($\delta$)는 0.33, 0.34 mm/s 정도로 Fe 이온상태가 둘 다 +3 가의 이온상태임을 알 수 있었다.

열자극발광 및 광자극발광 측정장치의 개발 (Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2015
  • 열이나 빛의 자극에 의한 물질의 발광현상, 즉 열자극발광(thermoluminescence, TL)과 광자극발광(optically stimulated luminescence, OSL)의 메커니즘을 규명하고, 이 현상을 방사선량의 측정에 활용할 수 있는 새로운 발광물질을 개발하는데 활용할 수 있는 측정장치를 개발하였다. 이는 열자극과 광자극을 동시에 가할 수 있는 장치로서, 열자극에 필요한 온도제어를 위하여 35 kHz의 정현파 전원으로 변환하여 스트립 형태의 발열부에 걸어주게 되며, 최대 $20K{\cdot}s^{-1}$의 온도상승률로 약 1K의 정밀도로 온도를 제어할 수 있었다. 광자극을 위한 광원으로 중심파장이 470 nm인 Luxeon V형 고휘도 LED 등 여러 파장영역의 LED나 레이저를 사용할 수 있도록 하였다. 대표적으로 470 nm의 LED로 $Al_2O_3$:C의 OSL을 측정하는 경우, 시료의 발광에서 자극광을 분리시키기 위하여 LED의 자극광은 단파장차단필터인 GG420을 통과시켜서 시료에 걸리게 하고, 시료의 발광은 대역통과필터인 UG11를 통과하여 광증배관에 걸리게 하였다. 아울러 시료에 따라 LED나 필터들을 다르게 조합할 수 있도록 하여 시료의 발광특성에 맞는 최적의 측정을 수행할 수 있다. PC로 측정장치의 전체적인 제어가 이루어지며 LabView로 개발한 제어프로그램은 그래픽사용자환경(GUI)으로 되어 있다. 이 연구를 통해서 개발한 장치로 LiF:Mg,Cu,Si와 $Al_2O_3$:C를 표준시료로 하여 TL과 OSL을 측정하였고, 이들의 발광특성이 기존에 알려진 특성을 재현하여 이 장치가 신뢰할 수 있는 성능을 내는 것을 확인할 수 있었다.

영남대학교병원의 환자안전을 위한 정도관리의 기초자료 분석 (Basic Data Analysis of the Quality Control for Patient Safety in Department of Radiation Oncologyat Yeungnam University Hospital)

  • 오세안;김성규;예지원;강민규;이준하;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.112-117
    • /
    • 2015
  • 미국의학물리학회(AAPM) TG-100 위원회에서 제시하고 있는 가이드 라인에 준하여 환자 안전에 대한 정도관리를 수립하기 위하여 영남대학교병원 방사선종양학과에서 환자를 치료하는 중에 발생한 오류들을 중심으로 오류 유형을 분석하여, 환자중심의 방사선치료를 시행할 때 환자 안전을 위한 정도관리의 가이드 라인을 정립하고자 한다. 방사선종양학과에서 방사선 치료를 하는데 있어서 일으킬 수 있는 오류들을 분석하여 오류를 일으키는 빈도와 오류가 일어날 때 환자 에게 미치는 심각성과 오류가 일어났을 때 감지하지 못하고 지나치는 확률을 점수로 평가하고자 한다. 오류를 일으킬 수 있는 곳으로는 CT 모의치료실, 치료계획실, 치료실로 나누어 조사하였다. CT 모의치료실에서는 고정기구 사용의 오류가 위험중요지수의 값이 60으로 가장 높았고, 모의치료 정보입력의 오류가 6으로 가장 낮게 나타났다. 치료계획실에서는 선량계산 모델 선택의 오류가 위험중요지수의 값이 168로 가장 높았고, 환자의 치료 시작일 오류가 36으로 가장 낮게 나타났다. 치료실에서는 테이블 Bar 오류가 위험중요지수의 값이 252으로 가장 높았고, 체중변화 오류가 190을 나타내었으며, 배게 오류가 24로 가장 낮게 나타났다.

전자 빔 조사후 PEBA (Poly Ether Block Amide)의 구조 및 기계적 특성 변화 (The Influence of E-beam Irradiation on POLY(ETHER-BLOCK-AMIDE) (PEBA, Pebax))

  • 신석영;최상규
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.205-209
    • /
    • 2014
  • 의료기기에 사용되는 고분자제품은 주로 감마선 또는 전자 빔을 이용하여 살균을 하는데, 살균에 의해 재료특성이 변화한다. 카테터에 많이 사용되는 고분자 폴리머인 poly(ether-block-amides) (PEBA)는 살균에 의한 물성변화가 더욱 심하다고 알려져 있다. 따라서 본 연구에서는 살균 후 PEBA의 물성변화를 측정하여 전자선 살균이 미치는 영향에 대해 평가하였다. PEBA에 전자선을 조사하고 노화를 촉진시켜 유효기간 동안의 변화를 확인하였다. 급속노화가 이루어진 환경은 온도가 55도, 습도가 50%인 오븐에서 수행되었다. PEBA의 경도는 polyester 함량에 따라 달라지는데 본 연구에서 사용된 PEBA 시료의 경도는 35D (soft)부터 72D (hard)였다. 전자빔 살균에 의한 PEBA의 분자량 변화와 인장강도 변화를 측정 하였다. 측정결과, 노화로 인해 분자량이 현저히 감소함을 확인 하였다. 35D 시료의 경우 분자량이 54350 g/mol에서 39250 g/mol으로 감소하였다. 또한 전자 빔에 의해 살균된 PEBA의 인장 강도 및 신장율도 현저히 감소하였다. 35D PEBA시료의 인장강도 역시 28040 kPa에서 24118 kPa로 14% 이상 감소하였다. 결론적으로 전자선 빔으로 의료용으로 사용되는 PEBA제품을 살균할 경우 물성변화가 심각하게 발생하므로 전자 빔 살균은 문제가 많음을 알 수 있었다.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

용액 공정을 통해 제조된 LaAlO3/SrTiO3 계면에서의 이차원 전자 가스의 전기적 특성 (Electrical Properties of Two-dimensional Electron Gas at the Interface of LaAlO3/SrTiO3 by a Solution-based Process)

  • 유경희;유상혁;조현지;안현수;정종훈;이형우;이정우
    • 마이크로전자및패키징학회지
    • /
    • 제31권1호
    • /
    • pp.43-48
    • /
    • 2024
  • SrTiO3 (STO) 기판 위에 성장된 LaAlO3 (LAO) 계면에서의 이차원 전자 가스 (2DEG)의 발견은 복합 산화물 이종 구조를 기반으로 한 혁신적인 전자소자 연구의 장을 제공함으로써 많은 관심을 받아왔다. 하지만 LAO 박막을 형성하기 위하여, 일반적으로 물리기상증착법(PVD)을 기반으로 하는 펄스 레이저 증착 (PLD) 등의 기법이 주로 사용되어 왔으나, 공정 비용이 많이 들며 LAO 내 La와 Al의 정밀한 조성 제어가 어려운 단점이 있다. 본 연구에서는 PVD에 비해 경제적인 대안인 용액 기반 공정을 사용하여 LAO 박막을 제조하였고, 그 전기적 특성을 평가하였다. LAO 전구체 용액의 농도를 다르게 하여 LAO의 두께를 2에서 65 nm까지 변화시켰으며, 각 두께에 따른 면저항 및 캐리어 농도를 도출하였다. 진공 열처리 후 형성된 전도성 채널의 면저항 값은 0.015에서 0.020 Ω·sq-1 범위로 나타났으며, 이러한 결과는 기존 문헌과 비교하였을 때 LAO와 STO 사이의 계면에서의 전자 이동뿐만 아니라 계면으로부터 떨어져 있는 STO bulk 영역으로의 전자 전도를 시사한다. 본 연구 결과는 용액 기반 공정을 통한 2DEG 형성 및 제어를 구현한 것으로, 공정 비용을 줄이고 전자 소자 제조에서 보다 광범위한 응용 가능성을 제시한다는 점에 그 의의가 있다.

Simulation Study on a Quasi Fermi Energy Movement in the Floating Body Region of FITET (Field-induced Inter-band Tunneling Effect Transistor)

  • Song, Seung-Hwan;Kim, Kyung-Rok;Kang, Sang-Woo;Kim, Jin-Ho;Kang, Kwon-Chil;Shin, Hyung-Cheol;Lee, Jong-Duk;Park, Byung-Gook
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.679-682
    • /
    • 2005
  • Negative-differential conductance (NDC) characteristics as well as negative-differential trans-conductance (NDT) characteristics have been observed in the room temperature I-V characteristics of Field-induced Inter-band Tunneling Effect Transistors (FITETs). These characteristics have been explained with inter-band tunneling physics, from which, inter-band tunneling current flows when the energy bands of degenerately doped regions align, and it does not flow when they don't. FITET is an SOI device and the body region is not directly connected to the external terminal. Therefore, Fermi energy in the body region is determined by electrical coupling among four regions - gate, source, drain and substrate. So, a quasi Fermi energy of the majority carriers in the floating body region can be changed by external voltages, and this causes the energy band movements in the body region, which determine whether the energy bands between degenerately doped junctions aligns or not. This is a key point for an explanation of NDT and NDC characteristics. In this paper, a quasi Fermi energy movement in the floating body region of FITET was investigated by a device simulation. This result was applied for the description of relation between quasi Fermi energy in the body region and external gate bias voltage.

  • PDF

EPID의 적정관리 도구로서의 유용성에 관한 연구 (The useage of the EPID as a QA tools)

  • 조정희;방동완;윤성익;박재일
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF