• 제목/요약/키워드: device parameter

검색결과 580건 처리시간 0.028초

폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가 (Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR)

  • 김대호;손상준;문준기;박장필;이제희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.35-46
    • /
    • 2021
  • 목 적 : 폐암의 정위 절제 방사선 치료(Stereotactic Ablative Radiation Therapy, SABR)시 복부압박을 이용한 치료계획과 양압지속유지기(The Continuous Positive Air Pressure, CPAP)를 이용한 치료계획을 비교, 분석하여 방사선 치료 효과 향상에 기여하고자 한다. 대상 및 방법 : 본원의 폐의 SABR 환자 중 2명을 대상으로 복부 압박 고정 장치(the Body Pro-Lok, BPL)와 CPAP를 이용한 치료 계획을 수립하여, RTOG 0813에서 제안한 parameter들과 균질도(Homogeneity Index, HI), 일치도(Conformity Index, CI)를 통해 치료계획을 분석하였다. 또한 모든 4D CT에서 각 Phase별 계획용 표적 체적(Planning Target Volume, PTV) 중심의 X, Y, Z축 움직임을 분석하고, PTV와 손상위험장기(Organ At Risk, OAR)의 체적과 평균 선량을 구하여 비교하였다. 그리고 4개의 원뿔형빔 전산화단층촬영(Cone Beam Computed Tomography, CBCT)을 이용하여, PTV 중심점과 0°, 90°, 180°, 270° 중 세 방향에서의 흉강내 접점까지의 직선거리를 측정하고, 각 방향에서 평균거리 값과의 차이를 비교하였다. 결 과 : BPL과 CPAP를 사용하여 얻은 치료계획은 모두 RTOG의 권고값을 따랐으며, 균질도와 일치도에서도 큰 차이가 없었다. PTV 중심의 X축, Y축, Z축 움직임은 A 환자의 경우 BPL 사용시 0.49 cm, 0.37 cm, 1.66 cm, CPAP 사용시 0.16 cm, 0.12 cm, 0.19 cm을 보였고, B 환자의 경우 BPL 사용시 0.22 cm, 0.18 cm, 1.03 cm, CPAP 사용시 0.14 cm, 0.11 cm, 0.4 cm을 보였다. CPAP 사용시 BPL 사용시보다 A 환자의 경우 ITV가 46.27% 감소하였고 좌측 폐의 체적이 41.94% 증가하였으며, 평균선량은 심장에서 52.81% 감소하였다. B 환자의 경우 좌측 폐 106.89%, 우측 폐 87.32% 체적이 증가하였고, 평균선량은 위에서 44.30% 감소하였다. 각 방향의 직선거리 값과 평균거리 값과의 최대 차이는 A 환자의 경우 a방향에서 0.05 cm, b방향에서 0.05 cm, c방향에서 0.41 cm 났고, B 환자의 경우 d방향에서 0.19 cm, e방향에서 0.49 cm, f방향에서 0.06 cm 차이가 났다. 결 론 : CPAP 사용시 폐용적의 증가를 통해 표적 근처 OAR의 선량을 BPL 사용시보다 더 효과적으로 감소시킬 수 있으며, 호흡에 따른 종양의 움직임 제한에도 더 효과적으로 기여할 수 있다는 것을 확인하였다. 추후 CPAP의 다양한 부위 적용과 다른 치료기와의 결합을 통해 방사선 치료 효과를 개선시킬 수 있을 것으로 사료된다.

식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가 (Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer)

  • 오현택;유순미;전수동;김민수;송흥권;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.33-41
    • /
    • 2019
  • 목 적: 식도암 방사선치료 시 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT) 및 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)에서 Jaw-Tracking 기법 유 무에 따라 저선량 영역에 대한 주변 정상장기의 용적선량을 분석하여 그 유용성을 평가하고자 한다. 대상 및 방법: 본 원에서 사용하고 있는 선형가속기 VitalBeamTM(Varian Medical System, U.S.A)으로 식도암 방사선치료를 받은 27명을 대상으로 하였으며, 치료계획은 Eclipse(Ver. 13.6 Varian, U.S.A)를 이용하여 Jaw-Tracking(JT)을 사용한 치료계획과 Non Jaw-Tracking(NJT) 치료계획을 수립하였으며, 치료계획용적(Planning Target Volume, PTV)에 빗장위림프절(Supraclavicular Lymph Nodes, SCL)이 포함되어 있는 T자형 PTV를 가진 환자를 대상으로 하였다. 조사범위에 대한 영향을 확인하기 위해 복강(Celiac) 포함 여부로 비교군을 나누었다. 수립된 치료계획의 비교를 위해 손상위험장기는 양측 폐, 심장, 척수를 비교하였으며 Conformity Index(CI), Homogeneity Index(HI)를 비교하였다. 임상적용 검증을 위해 전자포탈영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 Portal Dosimetry를 실시하였고, 선량 영역의 임계치(Threshold)를 10 %, 5 %, 0 %로 매개변수로 설정하여 감마분석을 실시하였다. 결 과: 모든 치료계획은 3 mm / 3 %, 감마통과율 95 % 기준에 대해 Threshold 10 %의 경우 95 % 이상으로 JT, NJT 모두 통과하였으며, IMRT는 Threshold가 5 %, 0 %로 줄어들수록 JT보다 NJT의 값이 1 % 이상 줄어 들었다. IMRT에서 양측 폐의 $V_5$$V_{10}$은 JT에서 Celiac을 포함하지 않을 때 최대 14.7 %, 평균 8.5 %, 5.3 % 만큼 감소했고, $D_{mean}$$72.3{\pm}51cGy$ 감소하였으며, Celiac을 포함할 때 JT에서 선량감소가 증가하였다. 심장의 $D_{mean}$$68.9{\pm}38.5cGy$, 척수의 $D_{max}$$39.7{\pm]30.1cGy$만큼 감소하였다. VMAT은 JT기법 사용 시 폐에서 $V_5$ 평균 2.5 % 감소하였고, 심장 및 척수에서 소량 감소하였으며, Celiac 포함 시 JT의 선량감소가 증가하였다. 결 론: 식도암 치료계획에서 IMRT가 JT 사용 시 양측 폐의 $V_5$, $V_{10}$에서 유의미한 감소가 나타났고, 저 선량영역에서 조사범위가 클수록 선량감소가 크게 나타났다. 따라서 식도암 방사선치료에는 IMRT가 VMAT보다 JT 적용 시 더 효과적이며, 저 선량영역에서의 MLC 누설 및 투과선량으로부터 정상장기를 보호할 수 있다.

식생유니트형 LID 시스템의 우수유출 지연효과에 대한 SWMM 전산모의와 인공강우 모니터링 간의 유의성 분석 (Analysis of Significance between SWMM Computer Simulation and Artificial Rainfall on Rainfall Runoff Delay Effects of Vegetation Unit-type LID System)

  • 김태한;최부헌
    • 한국조경학회지
    • /
    • 제48권3호
    • /
    • pp.34-44
    • /
    • 2020
  • 본 연구는 식생기반 LID 시스템 모델을 기반으로 생태적 구성요소의 성능 분석 방향을 제시하기 위해, SWMM 전산모의와 강우·유출 모의장치를 이용하여 모니터링 결과 간의 통계적 유의성을 분석하고, 시스템 사전설계에 요구되는 기초자료를 제공하고자 한다. 또한, 선행연구에서 상대적으로 논의가 부족했던 식생기반 LID 시스템의 토양, 식생 모델 및 분석 방안을 종합하고, 장치형 LID 시스템을 대체할 수 있는 성능 정량화 방향을 제시하려 한다. 인공강우재현 모니터링 40분 경과 후 실험구와 대조구 모두 최대강우강도인 142.91mm/hr(n=3, sd=0.34), 142.24mm/hr(n=3, sd=0.90)로 집계되었다. 우량주상도 대비 10분, 50분 구간은 낮은 강우강도가 재현되었으며, 20분, 30분, 40분 구간은 높은 강우강도가 확인되었다. 우수유출 지연효과의 경우, 실험구의 유출강도 저감량은 대조구의 최대유출강도가 발생된 50분에 0.46mm/min을 기록하여, 79.8% 저감된 것으로 분석되었다. 전산모의의 경우, 실험구의 유출강도 저감량은 대조구의 최대유출강도가 발생된 50분에 0.05mm/min을 기록하여, 99.1% 저감된 것으로 모의되었다. 최대 강우유출강도의 경우, 실험구(Dv=30.35, NSE=0.36)는 인공강우 모니터링과 SWMM 전산모의가 동일하게 70분에 각각 0.77mm/min, 1.06mm/min을 기록하였다. 대조구(Dv=17.27, NSE=0.78)도 동일하게 50분에 각각 2.26mm/min, 2.38mm/min으로 집계되었다. 상기 연구결과를 통해 강우·유출 모의장치와 SWMM 전산모의 간의 통계적 유의성을 통해 단일 식생이 적용된 LID 시스템의 우수유출저감 성능의 사전설계 방향을 제시할 수 있었다. 또한, LID 시스템의 토양, 식생 모델 및 분석방법을 종합하여, 사전설계와 연계 가능한 식생 및 토양 부문의 매개변수 정량화 방안이 정리되었다. 다만, 단일 식생기반 LID 시스템으로 유형과 물리적 변수가 제한되었고, 모니터링, 전산모의 결과 간의 통계적 유의성 보정에 요구되는 알고리즘 연구가 후속되어야 할 것으로 판단된다.

단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용 (Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT)

  • 정희라;강진우;권오준;김호진;정다빈;이재현;허영철
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.669-676
    • /
    • 2020
  • 본 연구의 목적은 Spectral CT에서 단색에너지(keV)와 조영제 희석비율의 변화에 따른 HU 값의 변화를 분석하고자 하였다. 검사장비로는 Spectral CT를 사용하였고, 20 cc syringe의 팬텀을 이용하여 조영제의 희석비율을 8:2, 7:3, 6:4, 5:5, 4:6, 3:7 총 6단계로 설정하였다. 이때 조영제는 비이온성 요오드 조영제(350 mg/ml)를 이용하였다. 획득한 데이터를 IQon-Spectral CT V4.7.5 프로그램을 사용하여 Monoenergy(MonoE) 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, 80 keV 총 9단계로 변화시켜 syringe axial 영상을 재구성하였다. 재구성한 syringe axial 단면 영상의 세 위치에서 HU 값을 측정하였으며, 총 1,620회 측정하였다. keV와 조영제 희석비율의 변화에 따른 HU 값을 분석한 결과, MonoE별 희석비율에 따른 HU 비교에서 모든 MonoE에서의 HU 값이 희석비율 8:2에서 가장 높았으며 3:7에서 가장 낮았다(p<0.05). 희석비율별 MonoE에 따른 HU 비교에서 모든 희석비율에서의 HU 값이 40 keV에서 가장 높았으며 80 keV에서 가장 낮았다(p<0.05). 인자별 상관성은 keV에 따른 HU 값은 -15.014 ± 0.298의 음의 상관성(R2=0.519)이 있었고 희석비율에 따른 HU값 은 -61.372 ± 3.608의 음의 상관성(R2=0.152)이 있었다(p<0.05). 결론적으로 keV 값과 조영제 희석비율이 증가할수록 HU 값은 감소하는 것을 확인하였으며 본 연구가 Spectral CT의 HU 값 관련 인자 연구에 있어 기초자료를 제공할 수 있을 것이라 사료된다.

의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향 (The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.17-22
    • /
    • 1999
  • 임상에서 사용되는 가속기의 설계특성변화가 빔 출력변화에 미치는 영향을 알아봄으로써 보다 효율적인 정도관리를 수행하고자 한다. 선형가속기를 구성하고 있는 여러 가지 요소 중에서 빔 조정 인자들인 이온원부의 입사전류 (INJ-I), 이온원부의 입사전압 (INJ-E), 가속전압 (PFN), 휨자석 전류 (BMI), 펄스반복주파수 (PRF)를 선택하여 디지털 메바트론 제어프로그램 상에서 선형가속기가 자동 제어되는 허용범위를 조사한 후 그 영역내에서 전류값들을 변화시켜가면서 선량에 어떠한 영향을 미치는지 알아보았다. 이온함을 사용하여 홉수선량을 측정하고 오실로스코프를 사용하여 빔 출력의 파형을 분석하였으며 방사선 계측장치로 대칭성과 평평도를 계측하였다. 방사선 가속 장치는 선형가속기 (Mevatron MD, Siemens, Germany)를 이용하였으며, 계측장치로는 RFAplus (Scanditronix, Sweden)를 사용하였다. 그리고 가속기의 설계특성변화 즉 , 빔 조정 인자들의 변화가 선량분포특성에 변화를 주는 것을 측정하기 위해 0.6cc 이온함(Capintec PR06C, USA), 미소전위계(Capintec192, USA)와 오실로스코프 (Tektronix, USA)를 사용하였다. 선형가속기의 선량률과 에너지변화에 영향을 미치는 인자들인 INJ-I, INJ-E, PFN, BMI, PRF의 전압과 전류값들을 변화시켰을 때 인자들마다 차이는 있었지만, 이온함을 사용하여 측정했을 때와 오실로스코프로 출력펄스의 변화를 보았을 때는 선량률의 변화를 확인할 수 있었다. 그러나 RFAplus로 에너지와 대칭성 등에 관한 그래프를 그렸을 때는 거의 동일한 결과를 나타내었다. 인자 INJ-I, INJ-E, PFN, BMI, PRF 들의 D10/D20은 0∼0.02, 대칭성은 0.1-0.2%, 평평도는 0.1∼0.4%의 미세한 변화를 보였다. 디지털화 된 각 인자들의 전류와 전압값들을 변화시킬 때 선량률에는 미세한 영향을 미치게 되지만, 기계자체에서 기준값에 맞추기 위해 자동 제어가 되어 선량분포에는 크게 영향을 미치지는 못하는 것으로 평가되어졌으나 빔 조정 인자들의 특성을 파악함으로써 정도관리의 기초자료를 확보하였다.

  • PDF

Virtual Digital Test Pattern Method를 이용한 CR 시스템의 영상처리 특성 분석 (Analysis of Image Processing Characteristics in Computed Radiography System by Virtual Digital Test Pattern Method)

  • 최인석;김정민;오혜경;김유현;이기성;정회원;최석윤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.97-107
    • /
    • 2010
  • 연구 목적은 virtual digital test pattern method을 이용하여 REGIUS 150 CR 시스템의 각 LUT별 프로세싱 커브를 도출하고, Dry Imager의 특성을 파악하여 CR의 영상처리 방법을 분석하는 것이다. 실험은 먼저, CR의 화상데이터에 맞게 virtual digital test pattern 파일을 만들고, 인위적으로 입력하여 virtual digital test pattern step의 변화를 통해 각 LUT(THX, ST, STM, LUM, BONE, LIN)별 프로세싱 커브를 구한다. 그리고 하드카피 이미지를 통해 Dry Imager의 프로세싱 커브도 도출한다. 마지막으로, CR 본체의 영상처리 파라미터들을 변화시켜 각각의 특성을 알아낸다. 실험 결과를 살펴보면, 입 출력 값을 통해 CR 시스템의 입력 다이나믹 레인지의 LUT별 프로세싱 커브를 구하였다. 프로세싱 커브는 모두 곡선으로 이어져 있었으며(LIN mode 제외), 각 커브마다 조금씩 차이를 보였다. 또한 Dry Imager의 프로세싱 커브는 중간부분에만 선형성이 나타났다. 그리고 프로세싱 파라미터의 G value는 기울기와, S value는 감도의 shift량과 관련된다는 것을 알 수 있었고, 선량에 따라 S value가 비례하여 변화한다는 것 또한 유추해 낼 수 있었다. 결론적으로 CR 시스템은 각 회사별로 내부 처리가 다르고, 구조 또한 복잡하기 때문에 내부 영상처리의 파악이 어렵다. 하지만 본 연구에서 사용한 virtual digital test pattern method는 CR 시스템의 내부처리 구조와 영상 파라미터의 변화에 따른 특성을 추정할 수 있으므로, 이 방법을 통해 타 장비의 CR 시스템과 Dry Imager의 전체적인 영상처리 특성을 비교, 분석 가능할 것이다.

인구이동 연구에 대한 공간통계학적 접근: 장소특수적 거리 패러미터의 추출과 공간적 패턴 분석 (A Spatial Statistical Approach to Migration Studies: Exploring the Spatial Heterogeneity in Place-Specific Distance Parameters)

  • 이상일
    • 한국지역지리학회지
    • /
    • 제7권3호
    • /
    • pp.107-120
    • /
    • 2001
  • 이 연구의 목적은 장소-특수적 거리 패러미터를 측정하는 방법론을 제시하고, 그것이 인구이동 연구에서 가지는 의미에 대해 미국의 48개 주간(州間) 인구 이동자료를 사례로 검토해보는 것이다. 전통적인 인구이동 연구에서 추출하는 거리 패러미터는 인구 이동량에 대해 거리가 가지는 평균적인 효과를 측정하는 것이다. 그러나, 그 평균적인 거리 패러미터는 모든 지역간 인구이동의 대표값일 뿐 인구이동에 있어 거리가 가지는 효과의 공간적 변이에 대해서는 아무런 통찰을 제공해 주지 못한다. 장소-특수적 거리 패러미터란 개개 소지역이 평균적인 거리 패러미터에 대해 가지는 상대적인 값이며, 거리가 인구이동에 대해 가지는 효과의 지역적 특이성을 측정하려고 한다. 이러한 연구는 최근 계량지리학 분야에서 발생하고 있는 변화에 부응하는 것이다. 1980년대 이후, 계량지리학은 공간통계학이라는 보다 폭넓은 개념의 확장과 일반연구환경으로서의 지리정보체계(GIS)치 성장으로 학문적 재구조화 과정 속에 있다. 이러한 재구조화 과정은 특정한 패러다임으로서의 탐구적 공간자료분석(ESDA)과 그것을 통계적으로 가능케 하는 국지 통계(local statistics)의 발달로 특징 지워진다. 통계적으로 가공되어 지역에 부여된 값으로 정의되는 국지 통계는 그것의 시각화를 효과적으로 수행하는 GIS와 결합함으로써, 시각화(visualization)와 과학활동으로서의 탐구(exploration)를 강조하는 탐구적 공간자료분석이라는 계량지리학의 새로운 패러다임을 효과적으로 수행하게 된다. 이러한 맥락에서, 장소-특수적 거리 패러미터는 하나의 국지 통계치로 인식될 수 있으며, 그것이 보여주는 공간적 패턴을 탐구하는 것은, 인구이동연구에서 탐구적 공간자료분석의 전형을 수행하는 것이라 올 수 있다. 장소-특수적 거리 패러미터는 출발지-특수적 거리 패러미터와 도착지-특수적 거리 패러미터로 나뉘어 지는데, 이러한 패러미터를 추출하기 위해서는 특정한 통계기법이 요구된다. 이러한 패러미터를 추출하기 위해 전통적인 혹은 보다 진보된 형태의 중력모델이나 엔트로피-극대화 모델이 활용될 수 있지만, 본 논문은 포아송 회귀분석을 이용함으로써 패러미터의 추출이 가장 효과적으로 이루어짐을 논증하고 있다. 이 방법론은 1985년과 1990년 사이에 발생한 미국 48개 주간 인구이동량에 대한 사례연구에 적용되었다. 그 연구 결과는 장소-특수적 거리 패러미터의 공간성을 명확히 보여준다. 즉, 평균적 거리 패러미터로 부터의 편기로 이해될 수 있는 장소-특수적 거리 패러미터들이 지역별로 상당한 차이를 보여줄 뿐만 아니라(공간적 이질성), 유사한 장소-특수적 거리 패러미터들이 공간적으로 집중되어 있음을 확인할 수 있었다(공간적 의존성). 지역차에 대한 강한 전통을 가지고 있는 지리학내에서 태동한 계량지리학이 지역적 특이성을 무시하는 방향으로 발전해 온 것은 아이러니라 할 수 있다. 그것은 계량적 방법론의 한계라기 보다는 그 방법론을 사용하는 전통적 계량지리학자의 한계라고 보아야 할 것이다. 이러한 의미에서 본 연구는 최근 계량지리학의 경향을 인구이동연구에 적용한 사례임과 동시에 맥락 의존성을 강조하는 보다 폭넓은 과학운동의 계량지리적 반응이다.

  • PDF

스마트온실 배양액 관리를 위한 클라우드 기반 데이터 분석시스템 설계 (Design of Cloud-Based Data Analysis System for Culture Medium Management in Smart Greenhouses)

  • 허정욱;박경훈;이재수;홍승길;이공인;백정현
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.251-259
    • /
    • 2018
  • 스마트온실에서 사용하고 있는 다양한 종류의 수경배양액 관리와 관련하여 ICT 기술을 활용한 작물생육 기반 배양액 제어시스템 개발을 위하여, 본 연구에서는 작물 생육단계별 시용배양액의 성분변화를 모니터링하고 이들 실측 데이터를 바탕으로 한 클라우드 기반 데이터 분석시스템을 설계하였다. 수집한 데이터 분석 및 시스템 구축을 위하여 인공광 스마트 온실에서 사용하는 관행의 무기 배양액, 기존 액비 및 폐기 농업부산물 유래 제조액비 등 수종의 배양액을 공시하였으며, 수경재배 작물 생육단계별 시용 배양액내 성분 변화패턴을 모니터링하였다. 발색법에 의한 흡광광도법을 활용하여 $NH_3-N$, $NO_3-N$, $NO_2-N$, $SiO_2$, $PO_4^{3-}$ 및 Cu 등 총 9종의 성분농도 변화를 산출하고 작물의 기초 생육량을 조사하였다. 각 작물의 기초 생육량 데이터는 오픈스택 클라우드 시스템에서 생성된 가상머신(Virtual machine)에 관계형 데이터베이스를 구축하여 수집 항목별로 분류 저장하였다. 저장된 작물별 배양액의 성분변화와 생육량 데이터는 노드제이에스(Node. js) 웹 프레임워크(Framework)를 통해 매주 수집된 데이터를 가시화하여 제공한다. 클라우드 기반 데이터베이스를 구축을 통하여 배양액 성분 실측치 비교와 작물 생육상황은 사용자 스마트 디바이스(Smart devices)를 활용, 작물종과 배양액 성분을 순차적 선택하고, 각 데이터의 비교 및 분석을 시계열 그래프로 실험 결과를 가시화할 수 있도록 하였다. 본 연구에서 개발한 클라우드 기반 데이터 분석시스템 스마트온실내 수경배양액 성분변화 및 재배 작물의 생육을 정기적으로 모니터링한 실측치를 기반으로 데이터베이스를 구축한 것으로 시설재배지나 인공광 스마트온실 등 다양한 농업현장에서 생육관리를 위하여 활용할 수 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF