• Title/Summary/Keyword: device net

Search Result 296, Processing Time 0.026 seconds

Parametric study of propeller boss cap fins for container ships

  • Lim, Sang-Seop;Kim, Tae-Won;Lee, Dong-Myung;Kang, Chung-Gil;Kim, Soo-Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.187-205
    • /
    • 2014
  • The global price of oil, which is both finite and limited in quantity, has been rising steadily because of the increasing requirements for energy in both developing and developed countries. Furthermore, regulations have been strengthened across all industries to address global warming. Many studies of hull resistance, propulsion and operation of ships have been performed to reduce fuel consumption and emissions. This study examined the design parameters of the propeller boss cap fin (PBCF) and hub cap for 6,000TEU container ships to improve the propulsion efficiency. The design parameters of PBCF have been selected based on the geometrical shape. Computational fluid dynamics (CFD) analysis with a propeller open water (POW) test was performed to check the validity of CFD analysis. The design of experiment (DOE) case was selected as a full factorial design, and the experiment was analyzed by POW and CFD analysis. Analysis of variance (ANOVA) was performed to determine the correlation among design parameters. Four design alternatives of PBCF were selected from the DOE. The shape of a propeller hub cap was selected as a divergent shape, and the divergent angle was determined by the DOE. Four design alternatives of PBCF were attached to the divergent hub cap, and the POW was estimated by CFD. As a result, the divergent hub cap with PBCF has a negative effect on the POW, which is induced by an increase in torque coefficient. A POW test and cavitation test were performed with a divergent hub cap with PBCF to verify the CFD result. The POW test result showed that the open water efficiency was increased approximately 2% with a divergent hub cap compared to a normal cap. The POW test result was similar to the CFD result, and the divergent hub cap with the PBCF models showed lower open water efficiency. This was attributed to an increase in the torque coefficient just like the CFD results. A cavitation test was performed using the 2 models selected. The test result showed that the hub vortex is increased downstream of the propeller.

A Study on DGPS Framework and Performance Evaluation for High-Accurate Localization based on GPS/AGPS (GPS/AGPS 기반의 고정밀 측위가 가능한 DGPS 프레임워크 및 성능평가에 관한 연구)

  • Seo, Ho-Seok;Jung, Se-Hoon;Oh, Min-Joo;Park, Dong-Gook;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.8
    • /
    • pp.927-938
    • /
    • 2014
  • A number of crime and disease relief situation show a clear increasing trend in domestic and overseas country. In particular, we desperately need a fast location information sharing with high accuracy for dealing with this situation efficiently. In this paper, we propose a DGPS framework and performance evaluation based on Web service enable increase location accuracy using low-cost GPS or AGPS. The framework consists of mobile station to realize the final service by receiving the correction values that are created in the base station closest to the current position from DGPS server, base station system to transmit the correct values to DPGS server by installing at base point and DGPS framework working at DGPS server. Our framework is fundamentally designed to respond based on XML to service request. In addition, for performance evaluation, we make use of 3 sites of Level 2 city base-station among the base stations being operated in Suncheon-si. Through performance evaluation, we show that our framework outperforms about 10%~15% in terms of error improvement rate, compared with the existing schemes. And we have the advantage that various services can be expanded owing to receiving the correction values through mobile device such as, smart phone, smart pad, net-book by using XML based Web services.

PILOT SCALE FISH PRODUCTION IN WATER RECYCLING SYSTEM (순환여과식 사육수정화 재사용방법에 의한 Pilot 규모의 어류양식시험)

  • KIM In-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.4
    • /
    • pp.195-206
    • /
    • 1980
  • Fish were grown in a water recycling rearing system consisting of a filter system, of which the area is about $30\;m^2$ and the volume of filter gravels is about $15\;m^3$, 6 rearing and 2 supplementary tans about $7\;m^2$ of surface area each. The results for 180 days from April 18 to October 14,1980 are summarized as following: One rearing tank was used for main experiment stocked with an equal number, and weight of each Israeli strain and $F_1$, hybrid between this strain and Korean local strain of common carp. Gross total production was 461 kg with a net production of 395 kg, and the Israeli strain grew to about 8 times initial weight and the hybrid about 6 times. Based on an analysis of results of the above mentioned main experiment and the other miscellaneous fish grown in the remaining tanks, it was considered to be feasible to implement a commercial production in this system by improving parts of the system and adding a number of the units. A special problem seems to be an adoption of more effective aeration device when fish loading increases. A solid waste removal system was deviced by use of by-pass flow ana this system worked very efficiently in view of supply water economy. A serious problem encountered in this experiment was heavy outbreaks of the gill-fluke, Dactylogyrus sp. which was relatively easily eradicated with Dipterex or DDVP treatment in the first trials, but later on strains which were resistant to any of these chemicals appeared.

  • PDF

A Study Analyzing Y Generation Users' Needs for Next Generation Digital Library Service (차세대디지털도서관서비스에 대한 Y세대 이용자의 요구분석 연구)

  • Noh, Younghee
    • Journal of the Korean Society for information Management
    • /
    • v.31 no.3
    • /
    • pp.29-63
    • /
    • 2014
  • This study attempted to reveal the characteristics of the Y generation, to derive the services of the next generation digital library, and to compare differences between the demands of the baby boom generation and the Y generation to some extent. As a result, first, it is shown that the digital device the Y generation uses the most, was a cell phone or smartphone, followed by desktop PC, notebook PC, and digital camera. Although there were some differences, the Y generation's use ratio of digital devices was substantially similar to the baby boomers'. Second, there was a significant difference between the Y generation and baby boom generation in terms of using digital services. While the Y generation used internet portals the most, the baby boom generation used e-mail service the most. Third, we surveyed the services which the Y generation and baby boom generation require for the next generation digital libraries, by grouping as follows: the cloud service, infinite creative space (maker space), big data, augmented reality, Google Glass, context-aware technologies, semantic services, SNS service, digital textbook service, RFID and QRCode service, library space configuration, a state-of-the-art display technology, and other innovative services. While the most demanded service by the Y generation was big data service, the baby boom generation most demanded digital textbook service.

Wireless u-PC: Personal workspace on an Wireless Network Storage (Wireless u-PC : 무선 네트워크 스토리지를 이용한 개인 컴퓨팅 환경의 이동성을 지원하는 서비스)

  • Sung, Baek-Jae;Hwang, Min-Kyung;Kim, In-Jung;Lee, Woo-Joong;Park, Chan-Ik
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.9
    • /
    • pp.916-920
    • /
    • 2008
  • The personal workspace consists of user- specified computing environment such as user profile, applications and their configurations, and user data. Mobile computing devices (i.e., cellular phones, PDAs, laptop computers, and Ultra Mobile PC) are getting smaller and lighter to provide personal work-space ubiquitously. However, various personal work-space mobility solutions (c.f. VMWare Pocket ACE[1], Mojopac[2], u-PC[3], etc.) are appeared with the advance of virtualization technology and portable storage technology. The personal workspace can be loaded at public PC using above solutions. Especially, we proposed a framework called ubiquitous personal computing environment (u-PC) that supports mobility of personal workspace based on wireless iSCSI network storage in our previous work. However, previous u-PC could support limited applications, because it uses IRP (I/O Request Packet) forwarding technique at filter driver level on Windows operating system. In this paper, we implement OS-level virtualization technology using system call hooking on Windows operating system. It supports personal workspace mobility and covers previous u-PC limitation. Also, it overcomes personal workspace loading overhead that is limitation of other solutions (i.e., VMWare Pocket ACE, Mojopac, etc). We implement a prototype consisting of Windows XP-based host PC and Linux-based mobile device connected via WiNET protocol of UWB. We leverage several use~case models of our framework for proving its usability.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation (히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyoung Hoon;Han, Sangjo;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.13-20
    • /
    • 2014
  • In natural gas distribution system, gas pressure is regulated correspond to requirement using throttle valve which is releasing huge pressure energy as useless form. The waste pressure can be recovered by using turbo machinery devices such as a turbo expander. In this process, excessive temperature drop occurs due to Joule-Thompson effect during the expansion process. Installing natural gas boiler before or after the turbo expander prevents temperature drop. Fuel cell or gas engine hybrid system further improve the efficiency, but 1~2% of total transporting natural gas is used for operating the hybrid system. In this study, a heat pump system is proposed as a preheating device which can be operated without using transporting natural gas. Thermodynamic analysis on evaporating and condensing temperatures and refrigerants is conducted. Results show that R717 is proper refrigerant for the hybrid system with high COP and low turbine work within the defined operating conditions. In domestic usage in Korea, the heat pump system has more economic feasibility owing to natural gas being imported with a high price of LNG form.

Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

  • Li, Yuquan;Hao, Botao;Zhong, Jia;Wang, Nan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.54-70
    • /
    • 2017
  • The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.

Performance of active PNC Handover and PNC Heart Beat based Beacon Alignment Schemes for Wireless PAN Systems (WPAN에서의 신속한 망 복구를 위한 능동적인 PNC 핸드오버방법 및 PNC Heart Beat 의 비컨 프레임 정렬 방식의 성능분석)

  • Nam Hye-Jin;Kim Jae-Young;Jeon Young-Ae;Lee Hyung-Soo;Kim Se-Han;Yoon Chong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2B
    • /
    • pp.117-128
    • /
    • 2006
  • For the legacy IEEE 802.15.3 WPAN protocol, an unpredictable piconet coordinator(PNC) leaving from a piconet without a proper handoff procedure causes an absence of PNC, and thus the piconet gets collapsed. In addition, several beacons from PNCs in adjacent piconets may be collided on a device(DEV) located between those piconets. This beacon collision eventually makes the DEV leave from the piconet. To remedy these two problems, we here propose an Active Seamless Coordinator Switching(ASCS) scheme and a PNC HB based Beacon Alignment(PHBA) one. In the ASCS scheme, a PNC assigns a number of DEVs as next possible PNCs in sequence for provisioning against the abrupt breakdown of the current active PNC. Each nominated DEV proactively sends a probe frame to confirm the operation status of the active PNC. For the case of no response from the PNC, the nominated DEV tries to become a new PNC immediately. In the second PHBA scheme, each PNC is allow to broadcast a special Heart Beat(HB) frame randomly during a superframe period. When a DEV receives a HB frame from other PNC, it promptly sends the related PNCs a special Hiccup Beat(HCB) frame with the superframe information of its associated PNC. As a result, the HCB frame makes both PNCs align their superframe beginning time in order to yield no more beacon collisions. For these two proposed schemes, we show the performance by simulations. We can confirm the enhancement of throughput for each superframe and average frame transfer delay, since each scheme can reduce the duration of piconet collapse. Finally, it is worth while to note that the proposed schemes can be operated with frames those are permitted in the legacy WPAN standard.

Carbon Dioxide Fixation and Light Source Effects of Spirulina platensis NIES 39 for LED Photobioreactor Design (Spirulina platensis NIES 39를 이용한 LED 광생물반응기에서의 이산화탄소 고정화와 광원 효과)

  • Kim, Ji-Youn;Joo, Hyun;Lee, Jae-Hwa
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • Optimal culture conditions of Spirulina platensis NIES 39 have been established using different types of light sources. Several types of photobioreactors were designed and the increase of biomass, the amount of $CO_2$, fixation and the production of chlorophyll content were studied. The result revealed that the input conditions of a 10 min period per 4 h at the condition of 5% $CO_2$ and 0.1 vvm, were excellent in the growth. The growth showing the maximum biomass accumulation is limited to 1.411 g/L when using the fluorescent bulb and the low powered surface mount device (SMD) type LEDs which were equipped-inside in the photobioreactor. However, the biomass exceeded up to 1.758 g/L level when a high powered red LED (color temperature : 12000 K) photobioreactor system was used. The $CO_2$ fixation speed and rate were increased. Although the total production of chlorophyll content undergoes a proportional increase in the biomass, the net content per dry cell weight (DCW) showed the higher production with a blue LED (color temperature : 7500 K) light than that of any other wavelengths. The carbon dioxide loss was marked as 0.15% of the inlet gas (5% $CO_2/Air$, v/v) at the maximum biomass culture condition.