• 제목/요약/키워드: deviation of response time

검색결과 129건 처리시간 0.023초

The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S

  • Jin, Cheonggil;Choi, Chuluong
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.123-137
    • /
    • 2021
  • In this study, we performed cross calibration of KOMPSAT-3 AEISS imaging sensor with reference to normalized pixels in the Landsat 8 OLI scenes of homogenous ROI recorded by both sensors between January 2014 and December 2019 at the Libya 4 PICS. Cross calibration is using images from a stable and well-calibrated satellite sensor as references to harmonize measurements from other sensors and/or characterize other sensors. But cross calibration has two problems; RSR and temporal difference. The RSR of KOMPSAT-3 and Landsat 8 are similar at the blue and green bands. But the red and NIR bands have a large difference. So we calculate SBAF of each sensor. We compared the SBAF estimated from the TOA Radiance simulation with KOMPSAT-3 and Landsat 8, the results displayed a difference of about 2.07~2.92% and 0.96~1.21% in the VIS and NIR bands. Before SBAF, Reflectance and Radiance difference was 0.42~23.23%. Case of difference temporal, we simulated by 6S and Landsat 8 for alignment the same acquisition time. The SBAF-corrected cross calibration coefficients using KOMPSAT-3, 6S and simulated Landsat 8 compared to the initial cross calibration without correction demonstrated a percentage difference in the spectral bands of about 0.866~1.192%. KOMPSAT-3 maximum uncertainty was estimated at 3.26~3.89%; errors due to atmospheric condition minimized to less than 1% (via 6S); Maximum deviation of KOMPSAT-3 DN was less than 1%. As the result, the results affirm that SBAF and 6s simulation enhanced cross-calibration accuracy.

주의력결핍 과잉행동장애에서 아동행동평가척도, 아동인성검사, 주의력장애 진단시스템 : 주의력결핍 과잉행동장애의 진단에서 차원적 진단도구들의 역할 (Child Behavior Check List, Korean Personality Inventory for Children, Computerized Attention Diagnostic System and ADHD : The Role of Dimensional Diagnostic Tool in ADHD Diagnosis)

  • 조환일;도진아;김현우;임명호
    • 대한불안의학회지
    • /
    • 제5권2호
    • /
    • pp.96-102
    • /
    • 2009
  • Objective : We investigated that ADHD categorical diagnosis and the dimensional tools for the evaluation of ADHD, widely used in the clinical field, such as the child behavior check list- Korean version (K-CBCL), Korean personality inventory for children (KPI-C), computerized Attention Diagnostic System (ADS). Method : The DSM-IV clinical diagnosis applied by child psychiatrist. K-CBCL, KPI-C, ADS are used. Ultimately, totally 161 ADHD children and 161 controls were evaluated. Subject group are consist of 202 boys (62.7%) and 120 girls (37.3%), and the mean age was $9.5{\pm}2.0$ years old. Results and Conclusion : Social problem, and attention problem in the K-CBCL, correct response time standard deviation in the computerized ADS were statistically significant different and attention problem in the K-CBCL, hyperactivity subscale in the KPI-C were significant trait, between subject group and control group. The ROC value of attention problem in the K-CBCL, hyperactivity subscale in the KPI-C, and ADS were .78, .93, .86. Finally, we found that K-CBCL, KPI-C, ADS were significant corelation with the ADHD categorical diagnosis.

  • PDF

PERFORMANCE TEST FOR A PDS MICRODENSITOMETER MODEL 1010GMS

  • Hong, S.S.;Paek, W.G.;Lee, S.G.
    • 천문학회지
    • /
    • 제25권1호
    • /
    • pp.23-46
    • /
    • 1992
  • The electrical, mechanical and optical capabilities have been tested of the microdensitometer PDS 1010GMS at the Korea Astronomy Observatory. The highest stage of scan speed 255 csu (conventional speed unit) is measured to be 47 mm/s. At this speed the position is displaced by $4{\mu}m$ to the direction of scanning and the density is underestimated by $0.4{\sim}0.7D$. Standard deviation in the measured density is proportional to $A^{-0.46}$, where A is the area of scan aperture. The accuracy of position repeatability is ${\pm}1{\mu}m$, and that of density repeatability is ${\pm}(0.003{\sim}0.03)D$. Callier coefficient is determined to be 1.37; the semispecular density is directly proportional to the diffuse density up to 3.5D. Because the logarithmic amplifier has a finite response time, the densities measured at high scan speeds are underestimated to the degree that speeds higher than 200 csu are inadequate for making an accurate astronomical photometry. After power is on, an about 5 hour period of warming is required to stabilize the system electrically and mechanically as well. On the basis of this performance test, we have determined the followings as the optimum scan parameters for the astronomical photometry: For the scan aperture $10\;\sim\;20{\mu}m$ is optimal, and for the scan speed. $20\;{\sim}\;50$ csu is appropriate. These parameter values are chosen in such a way that they may keep the density repeatability within ${\pm}0.01D$, the position displacement under $1{\mu}m$, and the density underestimation below 0.1D even in high density regions.

  • PDF

Alverine의 정량을 위한 Ion-Selective Electrodes (Ion-Selective Electrodes for the Determination of Alverine)

  • 이은엽;김기묘;김성진;허문희;안문규
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.79-84
    • /
    • 1995
  • Alverine에 대한 anionic counter ion으로서 acid red 97의 이용 가능성을 살펴보았다. PVC와 가소제의 비율이 같을 때 적절한 감응과 긴 수명을 나타내었으며, 검량선은 $1.0{\times}10^{-5}M$까지 직선성이었고 그 감응 기울기는 55.35mV/dec., 변동계수는 0.61이었다. Methylephedrine에 대하여는 -2.626, histidine에 대하여는 -2.216등의 선택계수를 보였고 pH 7.0~4.0에서 안정된 전위값을 얻을 수 있었다. $10^{-4}M$ 이하에서 20~30초 이내, 그 이상의 농도에서는 약 10초 이내에서 안정된 전위값을 얻을 수 있었다.

  • PDF

Predicting rock brittleness indices from simple laboratory test results using some machine learning methods

  • Davood Fereidooni;Zohre Karimi
    • Geomechanics and Engineering
    • /
    • 제34권6호
    • /
    • pp.697-726
    • /
    • 2023
  • Brittleness as an important property of rock plays a crucial role both in the failure process of intact rock and rock mass response to excavation in engineering geological and geotechnical projects. Generally, rock brittleness indices are calculated from the mechanical properties of rocks such as uniaxial compressive strength, tensile strength and modulus of elasticity. These properties are generally determined from complicated, expensive and time-consuming tests in laboratory. For this reason, in the present research, an attempt has been made to predict the rock brittleness indices from simple, inexpensive, and quick laboratory test results namely dry unit weight, porosity, slake-durability index, P-wave velocity, Schmidt rebound hardness, and point load strength index using multiple linear regression, exponential regression, support vector machine (SVM) with various kernels, generating fuzzy inference system, and regression tree ensemble (RTE) with boosting framework. So, this could be considered as an innovation for the present research. For this purpose, the number of 39 rock samples including five igneous, twenty-six sedimentary, and eight metamorphic were collected from different regions of Iran. Mineralogical, physical and mechanical properties as well as five well known rock brittleness indices (i.e., B1, B2, B3, B4, and B5) were measured for the selected rock samples before application of the above-mentioned machine learning techniques. The performance of the developed models was evaluated based on several statistical metrics such as mean square error, relative absolute error, root relative absolute error, determination coefficients, variance account for, mean absolute percentage error and standard deviation of the error. The comparison of the obtained results revealed that among the studied methods, SVM is the most suitable one for predicting B1, B2 and B5, while RTE predicts B3 and B4 better than other methods.

Evaluation of Cardiac Mechanical Dyssynchrony in Heart Failure Patients Using Current Echo-Doppler Modalities

  • Rehab M. Hamdy;Hend Osama;Hanaa M. Fereig
    • Journal of Cardiovascular Imaging
    • /
    • 제30권4호
    • /
    • pp.307-319
    • /
    • 2022
  • BACKGROUND: Current guidelines indicate electrical dyssynchrony as the major criteria for selecting patients for cardiac resynchronization therapy, and 25-35% of patients exhibit unfavorable responses to cardiac resynchronization therapy (CRT). We aimed to evaluate different cardiac mechanical dyssynchrony parameters in heart failure patients using current echo-Doppler modalities and we analyzed their association with electrical dyssynchrony. METHODS: The study included 120 heart failure with reduced ejection fraction (HFrEF) who underwent assessments for left ventricular mechanical dyssynchrony (LVMD) and interventricular mechanical dyssynchrony (IVMD). RESULTS: Patients were classified according to QRS duration: group I with QRS < 120 ms, group II with QRS 120-149 ms, and group III with QRS ≥ 150 ms. Group III had significantly higher IVMD, LVMD indices, TS-SD speckle-tracking echocardiography (STE) 12 segments (standard deviation of time to peak longitudinal strain speckle tracking echocardiography in 12 LV-segments), and LVMD score compared with group I and group II. Group II and group III were classified according to QRS morphology into left bundle branch block (LBBB) and non-LBBB subgroups. LVMD score, TS-SD 12 TDI, and TS-SD 12 STE had good correlations with QRS duration. CONCLUSIONS: HFrEF patients with wide QRS duration (> 150 ms) had more evident LVMD compared with patients with narrow or intermediate QRS. Those patients with intermediate QRS duration (120-150 ms) had substantial LVMD assessed by both TDI and 2D STE, regardless of QRS morphology. Subsequently, we suggest that LVMD indices might be employed as additive criteria to predict CRT response in that patient subgroup. Electrical and mechanical dyssynchrony were strongly correlated in HFrEF patients.

주문형 비디오 서버를 위한 실측 기반 적응형 확률 승인 제어 기법 (Measurement-Based Adaptive Statistical Admission Control Scheme for Video-On-Demand Servers)

  • 김인환;김정원;이승원;정기동
    • 한국정보처리학회논문지
    • /
    • 제7권12호
    • /
    • pp.3794-3803
    • /
    • 2000
  • 주문형 비디오 서버(Video-on-Demand server)에서 멀티미디어 데이터를 효과적으로 서비스 하기 위해 사용되는 승인제어는 시스템의 정확한 여유 자원 상태의 파악을 통해서 이루어져야 한다. 여러 자원 중에서도 디스크 자원은 요구에 대한 응답 시간이 디스크 외적인 요소에 의해 불규칙적이며 요구량 또한 편차카 크므로 적응성 있는 승인 제어가 필요하다. 기존의 승인 제어 기법에서는 이론적인 수치를 통해 승인 여부를 판단하였고, 실측에 기반할 지라도 서비스 상황에 따른 대처가 미흡했다. 본 논문에서 제안하는 실측 기반 적응형 확률 승인 제어 기법은 실제 서비스 환경에서 오프라인(Off-line) 처리 과정과 온라인(On-line) 처리 과정의 두 단계를 실시한다. 이를 통해 시스템의 자원 상황을 정확히 파악할 수 있고 상황에 따라 적응성 있게 승인 여부를 결정할 수 있다. 따라서 최대한의 자원 활용과 QoS(Quality of Service)를 동시에 보장할 수 있다. 모의 실험에서는 실측을 통해 얻어진 성능의 정확성과 요구 대역폭에 따른 적응성 있는 제어를 보임으로써 비디오 서버가 QoS를 보장하면서 최대한의 자원 활용이 가능함을 보였다.

  • PDF

적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가 (Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test)

  • 윤석태
    • 한국산업정보학회논문지
    • /
    • 제28권6호
    • /
    • pp.21-27
    • /
    • 2023
  • 현대 함정은 외부로 방사되는 적외선 신호를 낮추기 위해 폐기관에 적외선 신호저감 장치(Infra-Red Signature Suppression system, IRSS)를 설치한다. 그리고 함정은 생의 주기가 매우 긴 전략 자산으로 탑재 장비들의 성능에 대한 높은 신뢰성을 충분히 확보해야 한다. 따라서, IRSS와 같은 장비들은 설계 단계에서 모형시험을 통해 성능평가를 하고 있다. IRSS의 모형시험에서는 다양한 계측기기들이 사용된다. 그러므로, 모형시험 단계 이전에 계측기들의 신뢰성을 평가해야 한다. 본 연구에서는 IRSS 모형시험에 사용되는 계측 장비들의 신뢰성 평가에 관한 연구를 수행하였다. 시험 장비와 계측기는 열 풍동 시험기, 피토 튜브와 디지털 차압계, 열전대 센서 그리고 디지털 기록계가 사용되었다. 계측 결과 열 풍동 시험기의 풍속이 증가할수록 유동의 계측 편차가 감소하였으며, 열전대 센서의 온도는 사용 방법에 따라 반응 속도 및 민감도의 차이를 보였다.

플래시 스토리지의 성능 지연 방지를 위한 비휘발성램 기반 쓰기 증폭 감소 기법 (NVM-based Write Amplification Reduction to Avoid Performance Fluctuation of Flash Storage)

  • 이은지;정민성;반효경
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.15-20
    • /
    • 2016
  • 플래시 메모리는 초소형 전자기기부터 미디어 서버에 이르기까지 현대의 다양한 시스템에서 스토리지로 활용되고 있다. 플래시 메모리의 쓰기 증폭 (Write Amplification)은 가비지 컬렉션에서 발생하는 것으로 불규칙적인 성능의 주요 원인으로 지적되고 있다. 갑작스러운 속도지연은 실시간성 미디어를 위한 스토리지 시스템에서 치명적인 단점이 될 수 있다. 본 논문은 비휘발성램을 플래시 메모리 스토리지의 버퍼캐시로 사용하고 두 계층 간의 협동적 데이터 관리를 통해 플래시 메모리의 쓰깆 WAF를 절감하는 기법에 대해 제안한다. 비휘발성램에 캐쉬된 데이터는 플래시 메모리에서 가비지 컬렉션 수행 시 복사하지 않도록 한다. 이것은 복사되는 페이지의 수를 감소시켜 스토리지의 성능 및 내구성을 향상시킨다. 제안된 기법은 ssdsim 시뮬레이터에 구현되었으며 WAF와 응답시간의 표준편차를 각각 51.4%와 35.4% 개선할 수 있음을 보인다.

5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구 (The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance)

  • 정해조;김희중;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.98-106
    • /
    • 2007
  • 2005년 6월 연세의료원 세브란스병원에서는 진단목적으로 20대의 5 mesa 화소 Totoku ME511L 평판 LCD 표시장치를 추가하여 PACS를 확장하였다. 20대의 Totoku ME511L 표시장치를 대상으로 반사, 휘도 반응, 휘도 공간 의존, 분해능, 잡음, 베일링 그레어, 그리고 색도 항목에 대하여 AAPM TG 18보고서에 기준하여 정량적인(또는 시각적인) 인수검사를 실시하였다. 측정에 사용된 장치는 색도를 측정할 수 있는 만원경식 휘도계, 조도계, 반사 측정에 필요한 빛 선원, 빛 차단 장치, 그리고 TG18 테스트 패턴들이었다. 선택된 8대의 표시장치에 대한 평균 확산 반사계수($R_d$)는 $0.019{\pm}0.02sr^{-1}$이었다. 휘도 반응 검사에서, 휘도비(LR), 최대 휘도 변이($L_{max}$), 그리고 최대 대조도 반응 변이는 각각 $550{\pm}100,\;2.0{\pm}1.9%$, 그리고 $5.8{\pm}1.8%$이었다. 휘도 균일도 검사에서, 최대 휘도 변이는 TG18-UNL10 테스트 패턴의 10% 휘도에 대하여 $14.3{\pm}5.5%$이었다. 분해능 측정은 휘도 측정법으로 수행하였으며 중심에서 퍼센트 휘도(${\Dalta}L$)는 $0.94{\pm}0.64%$이었다. 시각적인 방법의 잡음측정의 모든 경우에서, 중앙 및 주위 4사분면에서 가장 작은 것을 제외하고 15개의 모든 정사각형의 표적을 인식할 수 있었다. 글레어 비(GR)은 $12,346{\pm}1,995$이었다. 최대 색도 균일도 지표(D)는 $0.0025{\pm}0.0008$이었다. 또한 국내 실정에 적합한 진단용 표시장치의 정도관리 가이드라인 연구 결과를 제시하였다. 모든 인수검사 결과는 AAPM TG18 보고서 기준에 포함되어 진단 목적으로 사용하기에 적합하였다. 결론으로 인수검사는 표시장치가 진단에 사용하기에 적합한 성능임을 알려줄 뿐만 아니라 정도관리의 가이드라인, 최적 판독 환경, 그리고 표시장치의 교체시기를 결정하여주는 중요한 역할을 할 수 있다.

  • PDF