• 제목/요약/키워드: deviation of position

Search Result 517, Processing Time 0.024 seconds

A Study on the Effect of Mandibular Orthopedic Repositioning Appliance (MORA) on Back Muscle Strength (Mandibular orthopedic repositioning appliance(MORA)가 배근력에 미치는 영향에 관한 연구)

  • 현기용;이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.10 no.1
    • /
    • pp.113-124
    • /
    • 1985
  • In order to observe the effect of mandibular orthopedic repositioning appliance (MORA) on body strength, the author measured back muscle strength with Digital Back Muscle DYNAMOMETER (TAKEI KIKI KOGYO Co., Tokyo, Japan) before MORA, 15 days after and 30 days after MORA in 12 men and then analysed them statistically. The subjects were weight-lifting athletes of Seoul Athletic High School without dysfunction of masticatory system. MORA was fabricated at 1.0-1.5rnm isotonically closed position (Myocentric Occlusion Position) from mandibular rest position (Myocentric Rest Position) using Myo-monitor (MyoTronics Research Inc., Seattle, Washington, USA) and-SVT C-II (Tokyo Shizaisha Inc., Tokyo, Japan). The results were as follows : 1. The mean of back muscle strength before MORA was 150 kg, that of 15 days after MORA was 165 kg (4.43% increase than before), and that of 30 days was 175 kg (10.76% increase than before). 2. There was a significant difference among back muscle strength before MORA, 15 days after and 30 days after MORA (P<0.01: repeated measures one-way ANOVA). 3. According to the result of determining mandibular position for MORA fabrication, mandibular rest position after relaxation with Myo-monitor was 3.2mm lower, 1.0mm posterior, and 0.5 mm left from centric occlusion. And the mean of the amount of lateral deviation was 0.7 mm.

  • PDF

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.318-325
    • /
    • 2003
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached the pinger is able to track comparatively easily had been developed, an availabilities of it were verified in water tank by using hydrophone and pinger. First of all, the receiving system for biotelemetry was calibrated so as to measure tracking of high precision or wide detection range. In the next place, the precision at narrow and wide beam array of receiving system by using hydrophone was investigated and the actual position was compared with measured hydrophone position. The mean standard deviations of the position by narrow beam array of receiving system were 6.4em in phase beam of fore-aft pair and 6.3em in starboard-port pair, and the wide beam array were 24em and 23em respectively. The precision of distance, position, and velocity at narrow beam array of receiving system by using pinger were investigated and the actual values were compared with measured values. The distance from receiving system to pinger was measured by the pinger synchronizing method, angle of direction of pinger was detected by the super short base line (SSBL) method. The three dimensional position of pinger to the receiving system was measured by combining of two kinds of methods (SPB method), the velocity of pinger was obtained with a differential of the three dimensional positions. The mean standard deviations of the distance by pinger synchronizing method in narrow beam array of receiving system was 1. 8 em, that of the position by SPB method was 7.7cm.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

A PROPORTIONAL ANALYSIS OF SOFT TISSUE PROFILE IN KOREAN YOUNG ADULTS (성인 정상 교합자의 연조직 비율에 관한 두부 X-선 계즉학적 분석)

  • Lee, Jeong-Hwa;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.405-417
    • /
    • 1994
  • The purpose of this study was to investigate proportional characteristics of soft tissue profile in Korean young adults. The sample consisted of 50 young adults(25 males and 25 females) who had pleasing profile and normal occlusion. Soft tissue proportional analysis was performed on lateral cephalograms taken in natural head position. The results were as follows : 1. Mean and standard deviation of proportional analysis were obtained. 2. Horizontal and vertical dimensions were larger in male. But facial proportion had no sexual difference except upper/lower face height (p<0.05). Upper/lower face height was larger in female than in male. 3. Vertical dimensions, except SN-ST, had high correlation with horizontal dimensions. 4. Head positioning error of natural head position was smaller than inter -individual variability of SN line.

  • PDF

Thermal System Analysis for Optimization of Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • 한근조;안성찬;심재준;한동섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.587-590
    • /
    • 2000
  • The new core making method economized on core sand requested. The new method is heating core box until it reaches reasonable temperature and then spraying core sand with core binder into core box. Inner temperature distribution have to uniform in order to form core of uniform thickness. Therefore, in this study we treat of inner temperature distribution of core box in priority. First, determine proper torch number. Next, optimize the torch position to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as followed : 1. The torch number that makes inner temperature distribution about $300^\circ{C}$ uniformly is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch position is optimized and AVEDEV is 5.85.

  • PDF

A Study of Obscuration on Height of Air Supply in Indoor Fire (옥내화재시 급기구의 높이에 따른 암흑화에 관한 연구)

  • 이창섭
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2001
  • This paper examined the variation in obscuration with height at indoor fire. The experiments were performed using a smoke box which is made for this job. It was found that the degree of smoke obscuration is depending upon the height. The obscurity at low position is less than that of high position. But there exist the deviation of obscurity at the position of air supply height.

  • PDF

The Results of Various Vestibular Function Tests in Young Male Adult (장정에 시행한 몇가지 평가기능 검사성적에 대한 고찰)

  • 박찬일;추광철;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.2.3-2
    • /
    • 1972
  • The vestibular function test reveals the objective findings of the impairment of the vestibular labyrinth. It's purpose is based on the analysis of the findings and detect the location and etiology of the labyrinthine impairment. In the vestibular function test, the vestibulo-spinal reflex has the clinical significance upon the tonus of the striated muscles by the labyrithine stimulation and contribute to regulating the posture and the position, at rest as well as in motion. The vestibulo-spinal reflex must performe as one of the routine vestivular function test because it can be evoked in man by such weak stimuli to the labyrinth as cannot induce vestibulo-ocular reflex. Authors performed the vestibular function test such as one leg test, gait test, stepping test and vertical writing test to one hundred of healthy and young male adult and received the following results. Results 1. One leg test: In 30 seconds, the frequency of dropping the leg on the ground was between 0 to 3 times in Rt., and 0 to 5 times in Lt. The mean frequency was 0.48 times in Rt., and 0.68 times in Lt. 2. Gait test: In forward gait; the range of the deviation was distributed 0 to 100 cm and mean range was 22.5cm to the Rt., 26.1cm to the Lt. In backward gait; the range deviation was distributed 0 to 140cm and mean range was 35.4cm to the Rt., 33.0cm to the Lt. 3. Stepping test: In normal head position; forward movement war 93% and backward 5%. The angle of displacement deviated to the Rt. side in 36%, and Lt. in 50%. The angle of rotation deviated to the Rt. side in 53 %, and Lt. in 36%. The mean values: angle of displacement was 22.05 degrees, angle of rotation was 24.40 degrees, distance of displacement was 48.95cm. In backward head position; Forward movement was 94% and backward was 3%. The angle of displacement deviated in 34%, and Rt. in 55%, to the Rt. side The angle of rotation deviated to the Rt. side in 50%, and Lt. in 42%. The mean values; angle of displacement was 29.72 degrees, angle of rotation was 39.53 degrees, distance of displacement was 44.17cm. 44.17cm. 4. Vertical writing test: The angle of deviation was between 0 to 16 degrees in all cases, and was between 0 to 12 degrees in the cases of normal head position. The mean angle of deviation was between 4.15 to 5.76 degrees on each side. The direction of deviation to the Rt. side was 54~69%, Lt. was 25~40% and 3~7% was vertical without deviation.

  • PDF

The correction of clean robot position error (청소 로봇의 위치오차 보정)

  • Yun, Dong-Woo;Oh, Sung-Nam;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.533-535
    • /
    • 2006
  • Cleaning robot that is selling in present city has various cleaning algorithm. However, error of most products happens on progress direction by small obstacle that do not properly and miss cleaning thereby happens. There is robot that correct own position, but is hard to use in general home because economical strain is very big because is high price product very. In this paper measures angular velocity of robot using deviation sensor, and do to correct error using turning angular velocity and vertical angular velocity. Because detailed cleaning such as high pice style is available without addition of expensive hardware in middle and low price style cleaning product thereby, can possess price competitive power.

  • PDF

Accuracy of the Position Fix and the Propagational Characteristic of Omega Radio Wave at Busan (부산지방에서의 오메가전파의 전파특성과 측정위치의 정도에 관하여)

  • An, Jang-Yeong;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.19-28
    • /
    • 1981
  • Accuracy of the position fix obtained by navigation with Omega in the capacity of worldwide navigation depends on the predicted propagation correction. The authors observe continuously the phase differences of the A-C pair and the A-E pair from April 17 to October 14, 1980, at Busan(35\ulcorner07'. 9N, 129\ulcorner06'. 3E), and analyze the characteristic of daily variation the relation between the theoretical PPC and the measu red PPC to study the accuracy of the position fix. The results are as follows: 1. The results of fourier's analysis for the theoretical PPC and the measured PPC are positive correlation in the coefficients ao, a2, a3 with A-C pair and in the coefficients aO-a3 with A-E pair, and those PPC are apparent to daily periodicity during all measured time. The initial phase is around to 280\ulcorner with A-C pair and 1800 with A-E pair. 2. Daily variatons of the phase difference tend to decrease and the time width to narrow from April toward July, but these variations are opposed to those from July toward October. 3. Mean value of total errors of the position fix by theoretical PPC is 2.67 miles and its standard deviationis O.90miles. 4. Mean value of total errors of the position fix by the measured PPC is 0.63 miles and its standard deviation is 0.217 miles.

  • PDF