• 제목/요약/키워드: deviation of distance

검색결과 442건 처리시간 0.028초

운전 중 동시과제 수행이 택시운전자의 차간거리 및 속도유지 능력과 피부전도도 변화율에 미치는 영향 (Effects of Secondary Tasks on Relative Change of Skin Conductance Level and Ability to Maintain Following Distance and Vehicle Velocity during Driving of Experienced Taxi Drivers)

  • 연홍원;윤희정;김한수;김지혜;최미현;최진승;지두환;탁계래;민병찬;정순철
    • 산업경영시스템학회지
    • /
    • 제35권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The purpose of this study was to investigate the effects of the secondary tasks such as sending text message (STM) and searching navigation (SN) on skin conductance level (SCL) and driving performance of relatively aged and high-experienced drivers. The subjects included 26 taxi drivers; 12 males aged $56.3{\pm}4.4$ with $28.4{\pm}6.4$ years of driving experiences and 14 females aged $55.5{\pm}3.5$ with $19.4{\pm}5.0$ years of driving experiences. All subjects were instructed to keep a constant following distance (30m) from the car ahead and a given vehicle speed (80km/h or 100km/h) in a driving simulator. The relative change of SCL, vehicle velocity deviations, and average following distances were measured during driving only and driving with secondary tasks. The relative change of SCL, average following distance, and vehicle velocity deviation were more increased during the driving with secondary tasks than driving only. The relative change of SCL, vehicle velocity deviation, and average following distance were more affected by driving with 100km/hr than 80km/hr of a given vehicle speed. Secondary tasks increased a work load of drivers in term of SCL change, and decreased driving performance in terms of the vehicle velocity deviation and average following distance.

A Probabilistic Method Based Protectability Evaluation of Distance Relay in Transmission Networks

  • Zhang, Wen-Hao;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung;Rim, Seong-Jeong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.346-353
    • /
    • 2008
  • This paper defines the concept of “protectability” for the performance evaluation of distance relay considering its sensitivity and selectivity. The paper starts from the probabilistic modeling of the errors, and based on this model, a detailed explanation of protectability calculation for each zone of the distance relay is presented. An effect of the Weighting Rate and the Measurement Deviation on the protectability evaluation is also given. By considering this effect, the optimization of relay setting can be realized. The proposed method is applied to a typical model system to show its effectiveness

데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도 (A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

데오드라이트 시스템의 측정 정확도에 대한 연구(II) -기준자 측정 높이에 따른 측정 정확도 (A Study on Measurement Accuracy of Theodolite System(II) -A Measurement Accuracy for a Height of Scale Bar)

  • 윤용식;이동주;정종길
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.37-43
    • /
    • 2004
  • A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.

2.45GHz 대역의 지하철 플랫폼에서 경로손실 특성 (Path Loss Characteristics in Subway Platform at 2.45GHz Band)

  • 최낙일;공민한;강영진;송문규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.318-321
    • /
    • 2003
  • In this paper, path loss and delay profile characteristics are measured in the subway platform. To evaluate the fading characteristics of the measured signals, the standard deviations are computed. The standard deviation is bigger for shorter distance. The shorter the distance, the bigger the phase difference between direct wave and reflected waves according the distance, which results in heavy fading. To compute the path loss according to distance, the average values of path loss exponent(n) is evaluated. The path loss exponents measured in the subway environment for Omni-VP(omni-directional vertical polarization) antenna and CP(circular polarization) antenna are 1.418 and 1.680, respectively, which are considerably less than 2.0, the free space path loss exponent.

  • PDF

초음파 이용 거리측정을 위한 센서 개발에 관한 연구 (Study on the Development of Sensors for Distance Measure Using Ultrasonic)

  • 박근철;이승희;박창수;김동원;김원택;전계록
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.46-50
    • /
    • 2014
  • In this paper, we report a novel algorithm based on phase displacement, which supplements conventional TOF methods for distance measurement using an ultrasonic wave. The proposed algorithm roughly measures the distance between the transmission part and the receiving part by using the initial TOF. Thereafter, the precise distance is determined by measuring the phase displacement value between the synchronizing transmission signal and the signal obtained at the receiving end. A distance measurement experiment using a micrometer was performed to verify the accuracy of the ultrasonic wave sensor system. We found that the mean errors from the one adopting the distance measurement algorithm based on phase displacement varied from a minimum of 0.03 mm to a maximum of 0.09 mm. In addition, the standard deviation varied from a minimum of 0.04 mm to a maximum of 0.07 mm, thus giving a precision of ${\pm}0.1$ mm.

상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

근거리 지진관측자료의 S파를 이용한 지진규모 평가 연구 (A Study on Estimating Earthquake Magnitudes Based on the Observed S-Wave Seismograms at the Near-Source Region)

  • 연관희;최신규;이강렬
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.121-128
    • /
    • 2024
  • There are growing concerns that the recently implemented Earthquake Early Warning service is overestimating the rapidly provided earthquake magnitudes (M). As a result, the predicted damages unnecessarily activate earthquake protection systems for critical facilities and lifeline infrastructures that are far away. This study is conducted to improve the estimation accuracy of M by incorporating the observed S-wave seismograms in the near source region after removing the site effects of the seismograms in real time by filtering in the time domain. The ensemble of horizontal S-wave spectra from at least five seismograms without site effects is calculated and normalized to a hypocentric target distance (21.54 km) by using the distance attenuation model of Q(f)=348f0.52 and a cross-over distance of 50 km. The natural logarithmic mean of the S-wave ensemble spectra is then fitted to Brune's source spectrum to obtain the best estimates for M and stress drop (SD) with the fitting weight of 1/standard deviation. The proposed methodology was tested on the 18 recent inland earthquakes in South Korea, and the condition of at least five records for the near-source region is sufficiently fulfilled at an epicentral distance of 30 km. The natural logarithmic standard deviation of the observed S-wave spectra of the ensemble was calculated to be 0.53 using records near the source for 1~10 Hz, compared to 0.42 using whole records. The result shows that the root-mean-square error of M and ln(SD) is approximately 0.17 and 0.6, respectively. This accuracy can provide a confidence interval of 0.4~2.3 of Peak Ground Acceleration values in the distant range.

적외선 분광 반사율에 의한 편차를 활용한 거리 측정 방법 (Distance Measurement Method using Deviation Due to Infrared Spectral Reflectance)

  • 모귀환;양재혁;김수민
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.262-265
    • /
    • 2021
  • 본 연구 목표는 조류 둥지에 의한 전신주 내의 사고를 사전에 방지하기 위해 전신주 중 둥지 설치가 가능한 공간 내에 센싱을 통해 조류가 둥지를 짓어 알을 낳기 전에 제거하기 위한 센서 노드 개발에 있다. 조류 둥지를 인식하기 위해서는 최초 설치하였을 때의 거리 측정 값과 이 후 측정되는 거리 값의 변화에 따라 예측 가능한 솔루션에 있다. 본 논문에서는 콘크리트, 철판, 나무, 비닐봉지를 대상으로 적외선을 설계하고 시험하였다. 전신주 내에 놓일 수 있는 물체를 대상으로 실험하여, 각 각의 분광 반사율에 의해 감지되는 분광을 포토다이오드를 통한 값의 표준 편차 그래프를 통해 물체의 대상을 예측하며, 거리 측정이 가능하게 되었다. 본 실험 결과로서 적외선 센서를 통해 전신주 내의 위험물에 대한 대상 정보(콘크리트, 철판, 나무, 비닐봉지)를 습득하게 되고 전력망 모니터링을 통해 안전한 전력망 구축과 자연과 상생 가능한 환경에 이바지 할 것으로 예측된다.

  • PDF

탄소강의 펄라이트 분율에 따른 미끄럼 마멸속도 편차 분석 (Analysis of Mean Deviation in Sliding-wear-rate of Carbon Steel with Various Pearlite Volume Fractions)

  • 김명곤;권혁우;허하리;김용석
    • 소성∙가공
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2015
  • The current investigation was performed to study sliding-wear-rate deviation (wear-rate data scatter) in carbon steels with various microstructures. Pure iron, 0.2 wt. % C steel, 0.45 wt. % C steel, and bearing steel (AISI52100) were used for the investigation. These steels possess different microstructures. Microstructures of the pure iron, two carbon steel and the bearing steel were full ferrite, ferrite + pearlite and full pearlite, respectively. Depending on the carbon content, the carbon steel had different pearlite-volume fractions. Dry sliding wear tests of the steel were conducted using a ball-on-disk wear tester at a sliding speed of 0.1 m/s using a bearing ball (AISI52100) as a counterpart. Applied load and sliding distance were 100 N and 300 m, respectively. More than three (up to twelve) tests were conducted for each steel under the same conditions, and the mean deviations in the wear rate of the steel (microstructure) were compared. The wear-rate deviation in the steel with ferrite + pearlite microstructure was higher than that with ferrite microstructure, and the deviation decreased with the increase of pearlite volume fraction. The pure iron and the bearing steel specimens showed much less deviation. The high deviation observed from the ferrite + pearlite steel was attributed to irregular subsurface-crack nucleation and growth at the interface between the two micro constituents (ferrite and pearlite) during the wear test.