• Title/Summary/Keyword: deviation correction

Search Result 275, Processing Time 0.025 seconds

Pulmonary Artery Angioplasty for Improving Ipsilateral Lung Perfusion in Adolescent and Adult Patients: An Analysis Based on Cardiac Magnetic Resonance Imaging and Lung Perfusion Scanning

  • Dong Hyeon Son;Jooncheol Min;Jae Gun Kwak;Sungkyu Cho;Woong-Han Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.4
    • /
    • pp.360-368
    • /
    • 2024
  • Background: The left pulmonary artery (LPA) may be kinked and stenotic, especially in tetralogy of Fallot, because of ductal tissue and anterior deviation of the conal septum. If LPA stenosis is not effectively treated during total correction, surgical angioplasty is occasionally performed. However, whether pulmonary artery (PA) angioplasty in adolescents or adults improves perfusion in the ipsilateral lung remains unclear. Methods: This retrospective review enrolled patients who underwent PA angioplasty for LPA stenosis between 2004 and 2019. Among patients who underwent a lung perfusion scan (LPS) or cardiac magnetic resonance imaging (cMRI) pre- and post-pulmonary angioplasty, those aged >13 years with <40% left lung perfusion (p-left) in the pre-angioplasty study were included. Preoperative and postoperative computed tomography, LPS, and cMRI data were collected. The perfusion ratio was analyzed according to the LPA's anatomical characteristics. Results: Seventeen adolescents and 16 adults (≥18 years old) were finally included (median age, 17 years). The most common primary diagnosis was tetralogy of Fallot (87.9%). In all patients, LPA angioplasty was performed concomitantly with right ventricular outflow tract reconstruction. No patients died. Preoperative p-left was not significantly different between adolescents and adults; however, adolescents had significantly higher postoperative p-left than adults. P-left significantly increased in adolescents, but not in adults. Seven patients had significant stenosis (z-score <-2.0) confined only to the proximal LPA and demonstrated significantly increased p-left. Conclusion: PA angioplasty significantly increased ipsilateral lung perfusion in adolescents. If focal stenosis is confined to the proximal LPA, PA angioplasty may improve ipsilateral lung perfusion, regardless of age.

Accuracy Assessment of Reservoir Depth Measurement Data by Unmanned Boat using GIS (GIS를 이용한 무인보트의 저수지 수심측정자료 정확도 평가)

  • Kim, Dae-Sik
    • Journal of Korean Society of Rural Planning
    • /
    • v.30 no.3
    • /
    • pp.75-84
    • /
    • 2024
  • This study developed the procedure and method for the accuracy assessment of unmanned boat survey data, based on the reservoir water depth data of Misan Reservoir, measured by the manned and unmanned boats in 2009 by Korea Rural Community Corporation. In the first step, this study devised the method to extract the contour map of NGIS data in AutoCAD to generate easily the reservoir boundary map used to set the survey range of reservoir water depth and to test the survey accuracy. The surveyed data coordinate systems of the manned and the unmanned boat were also unified by using ArcGIS for the standards of accuracy assessment. In the accuracy assessment, the spatial correlation coefficient of the grid maps of the two measurement results was 0.95, showing high pattern similarity, although the average error was high at 78cm. To analyze in more detail assessment, this study generated randomly the 3,250m transverse profile route (PR), and then extracted grid values of water depth on the PR. In the results of analysis to the extracted depth data on PR, the error average difference of the unmanned boat measurements was 73.18cm and the standard deviation of the error was 55cm compared to the manned boat. This study set these values as the standard for the correction value by average shift and noise removal of the unmanned boat measurement data. By correcting the unmanned boat measurements with these values, this study has high accuracy results, the reservoir water depth and surface area curve with R2 = 0.97 and the water depth and storage volume curve with R2 = 0.999.

Surgery-early approach combined with condylectomy for correction of severe facial asymmetry with mandibular condylar hyperplasia: a case report

  • Hikari Suzuki;Shinnosuke Nogami;Yoshio Otake;Yuri Takeda;Junji Sugawara;Tetsu Takahashi;Kensuke Yamauchi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.4
    • /
    • pp.227-234
    • /
    • 2024
  • In patients with unilateral mandibular condyle hyperplasia, whether to perform condylectomy and orthognathic surgical procedures at the same time or orthognathic surgery in two stages for remains controversial. Reported here is a case of facial asymmetry with mandibular condyle hyperplasia, for which condylectomy and orthognathic surgery procedures were performed at the same time. A 28-year-old woman was presented to our department with chief complaints of left deviation of the mandible and right temporomandibular joint (TMJ) noise. Findings obtained in several imaging examinations led to a diagnosis of facial asymmetry associated with right mandibular condyle hyperplasia. Following 3 months of preoperative orthodontic treatment, in October 2018 under general anesthesia the patient underwent a right mandibular condylectomy, Le Fort I osteotomy, right mandibular sagittal split ramus osteotomy, and left mandibular inverted L ramus osteotomy. In examinations up to 3 years after surgery, good results were noted. For this case of severe facial asymmetry with mandibular condyle hyperplasia, early surgery and condylectomy were performed simultaneously to significantly shorten the total treatment time. The effectiveness of a surgery-early approach was confirmed by no postoperative findings indicating abnormalities in the TMJ or retroversion.

Development of Ground Motion Models within Rock Based on Ground Motion Data Measured at Borehole Seismic Stations (시추공 관측소 계측 자료에 기반한 암반의 지반운동 모델 개발)

  • Sinhang Kang
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.301-311
    • /
    • 2024
  • In South Korea, following the 2016 Gyeongju and 2017 Pohang earthquakes, the need for earthquake disaster prevention has been increasing. Reliable techniques for probabilistic seismic hazard analysis and ground motion models are required for quantifying earthquake damage. Recently, there has been growing demand for deep underground facilities, necessitating accurate quantification techniques for earthquake damage in deep underground. In this study, ground motion models within rock were proposed using ground motion data measured at borehole seismic stations. A regression analysis, a type of empirical technique, was applied to 17 periods selected in a range from 0.01 to 10 s of spectral accelerations to develop the ground motion models. Residual analysis was performed to evaluate and improve the prediction performance of the ground motion model, with correction factors added to the model equation. When applying the proposed model, the group means of residuals approached zero, and the standard deviation of total residuals, similar to existing models proposed in other countries, confirmed the reliability of the proposed model.

Development of an EMS Thoracic Support Harness for Upper Posture Correction (상부 자세 교정을 위한 EMS 흉추 보호대 개발)

  • Minsuk kim;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.28 no.5
    • /
    • pp.50-67
    • /
    • 2024
  • This study developed a thoracic support harness designed to contract the lower trapezius muscle through electrical muscle stimulation (EMS) applied to the subscapularis region. Fifteen female office workers in their 30s who were diagnosed with forward head posture syndrome (FHP) participated in experiments evaluating stiffness and rigidity of the upper trapezius muscle. The experiment measured FHP Angle (FHPA), Neck Flexion Angle (NFA), Neck Extension Angle (NEA), Neck Rotation Angle (NRA), and Visual Analog Scale (VAS) for pain perception and comfort. Participants were divided into four groups (A, B, C, D) for sequential testing. Group A served as control, Group B performed upper trapezius stretching (UTS), Group C received EMS to stimulate weakened lower trapezius muscle. Group D underwent both UTS and EMS concurrently. After intervention, cervical angles and VAS scores were compared between groups. Statistical analysis using t-tests revealed significant differences between Group A and Group B, C, or D. ANOVA was used to test mean differences among groups, followed by Tukey-Kramer post-hoc tests to identify specific group differences. Results indicated that stretching or EMS alone had limited effects, while a combination of stretching and EMS showed significant benefits. The comfort level of the harness was rated at an average of 3.86 with a standard deviation of 2.38

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Improving Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: I. Correction for Local Temperature under the Inversion Condition (기상청 동네예보의 영농활용도 증진을 위한 방안: I. 기온역전조건의 국지기온 보정)

  • Kim, Soo-Ock;Kim, Dae-Jun;Kim, Jin-Hee;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.2
    • /
    • pp.76-84
    • /
    • 2013
  • An adequate downscaling of the official forecasts of Korea Meteorological Administration (KMA) is a prerequisite to improving the value and utility of agrometeorological information in rural areas, where complex terrain and small farms constitute major features of the landscape. In this study, we suggest a simple correction scheme for scaling down the KMA temperature forecasts from mesoscale (5 km by 5 km) to the local scale (30 m by 30 m) across a rural catchment, especially under temperature inversion conditions. The study area is a rural catchment of $50km^2$ area with complex terrain and located on a southern slope of Mountain Jiri National Park. Temperature forecasts for 0600 LST on 62 days with temperature inversion were selected from the fall 2011-spring 2012 KMA data archive. A geospatial correction scheme which can simulate both cold air drainage and the so-called 'thermal belt' was used to derive the site-specific temperature deviation across the study area at a 30 m by 30 m resolution from the original 5 km by 5 km forecast grids. The observed temperature data at 12 validation sites within the study area showed a substantial reduction in forecast error: from ${\pm}2^{\circ}C$ to ${\pm}1^{\circ}C$ in the mean error range and from $1.9^{\circ}C$ to $1.6^{\circ}C$ in the root mean square error. Improvement was most remarkable at low lying locations showing frequent cold pooling events. Temperature prediction error was less than $2^{\circ}C$ for more than 80% of the observed inversion cases and less than $1^{\circ}C$ for half of the cases. Temperature forecasts corrected by this scheme may accelerate implementation of the freeze and frost early warning service for major fruits growing regions in Korea.

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (1) - Design and production of system - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (1) -시스템의 설계 및 제작 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.218-229
    • /
    • 2003
  • A new biotelemetry method that the installation and the treatment of equipment is convenient and the instantaneously detailed location of the fish attached the pinger is able to track comparatively easily was developed. The receiving system in this biotelemetry method was advanced for track the detailed behavior of the fish by the miniature tracking pinger, because it was a burden to fish to add the pinger with the water temperature and the pressure sensor. By combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger, the three dimensional locations of fish to the receiving transducer is gotten instantaneously. The receiving system is devised to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry developed by the present authors and the hydrophone array configuration. The measurement distance error in the pinger synchronizing method is minimized through the correction of which the deviation of transmission pluse period of pinger is caused by changing water temperature. A prototype system which is able to track the instantaneously detailed location of the fish by the SSBL and pinger synchronizing biotelemetry (SPB) method was produced.

Congenital cystic adenomatoid malformation (선천성 낭포성 선종양기형 -1례 보고-)

  • Sun, Kyung;Baek, Kwang-Je;Lee, Chol-Sei;Chae, Sung-Soo;Kim, Hark-Jei;Kim, Hyung-Mook
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.118-124
    • /
    • 1984
  • Congenital Cystic Adenomatiod Malformation (C.C.A.M.) is rare, but one of the most common congenital pulmonary anomalies that cause acute respiratory distress in the newborn infants. It is characterized and differentiated from the diffuse pulmonary cystic disease pathologically, i.e. adenomatoid appearance due to marked proliferation of the terminal respiratory components. An 2/12 year old male patient was suffered from respiratory distress and cyanosis on crying since birth, but no specific therapy was given. With progression of symptoms, he came to Korea University Hospital for further evaluation and then transfered to Dept. of Chest Surgery for operative correction under the impression of Congenital Obstructive Emphysema suggested by a pediatrician. On gestational and family history, there was nothing to be concerned such as congenital anomaly. Physical examinations showed; moderate nourishment and development (Wt. 5.5kg), cyanosis on crying, both intercostal and lower sternal retraction on inspiration, Lt. chest building with tympany, Rt. shifting of cardiac dullness, decreased breathing sound with expiratory wheezing on entire Lt. lung field, decreased breathing sound on Rt. upper lung filed, and tachycardia. The remainders were nonspecific. Laboratory findings were normal except WBC $14000/mm^3$ (lymphocyte 70%), Hgb 9.8m%, Hct 28%, negative Mantaux test, and sinus tachycardia and counter-clockwise rotation on EKG. Preoperative simple Chest PA revealed marked hyperlucent entire Lt. lung, herniation of Lt. upper lobe to Rt., collapsed Rt. upper lobe, tracheal deviation and mediastinal shifting to Rt., and no pleural reaction. At operation, after Lt. posterolateral thoracotomy, 4th rib was resected. Operative findings were severe emphysematous changes limited to both lingular segmentectomy was done. The resected specimen showed slight solidity, measuring $8{\times}4.5{\times}2cm$ in size, and small multiple cystic spaces filled with air. Microscopically, entire tissue structures were glandular in appearance, cyst were lined by ciliated columnar epithelium, and occasional cartilages were noted around the cystic spaces. Bronchial elements were dilated but normal pattern on histologically. The patient had a good postoperative courses clinically and radiologically, and discharged on POD 10th without event. The authors report a case of Cogenital Cystic Adenomatoid Malformation (C.C.A.M.)

  • PDF

Preliminary study on the use of near infrared spectroscopy for determination of plasma deuterium oxide in dairy cattle

  • Purnomoadi, Agung;Nonaka, Itoko;Higuchi, Kouji;Enishi, Osamu;Amari, Masahiro;Terada, Fuminori
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4101-4101
    • /
    • 2001
  • Information of body composition (fat and protein) in living animal is important to determine the nutrients requirement. Deuterium oxide (D2O) dilution techniques, as one of isotope dilution techniques have been useful for the prediction of body composition. However, the determination of D2O concentration is time consuming and complicated. Therefore this study was conducted to develop a new method to predict D2O concentration in plasma using near infrared spectroscopy technique (NIRS). Four dairy cows in early lactation were used. They were fed total mixed ration containing conr silage, timothy hay, and concentrates to make 17.0%CP and 14.0 MJDE/kgDM. Dosing D2O was at week 1,3 and 5 after parturition. After dosing D2O, the blood was collected from hour 0 to 72. Blood samples were then centrifuge at 3,000 rpm for 10 minutes to obtain plasma. D2O concentration was analyzed by gas chromatograph (deuterium oxide analyzable system, HK102, Shokotsusyou) after extracted from plasma by liophilization. Plasma sample was scanned by NIRS using Pacific Scientific (Neotec) model 6500 (Perstorp Analytical, Silver Spring, MD) in the range of wavelength from 1100 to 2500 nm. Calibration equation was developed using multiple linear regression. Sample from one animal (cow #550; n: 74) was used for developing the calibration while the rest three animals were used for validating the equation. The range, R and SEC of the calibration set samples were 135-925 ppm, 0.93 and 48.1 ppm, respectively. Validation of the calibration equation for three individual cows was done and the average of NIR predicted value of D2O at each collection time from three weeks injection showed a high correlation. The range, r and 53 of plasma from cow #474 were 322-840 ppm,0.93 and 53.1; cow #478 were 146-951 ppm,0.95 and 39.8; cow #942 were 313-885 ppm,0.95 and 37.2, respectively. Judgement of accuracy based on ratio of standard deviation and standard error in validation set samples (RPD) for cow #474, #478 and #942 were 2.2,4.3 and 3.4, respectively. The error in application due to the variation between individual was considered smaller than the bias from collection period, however, this prediction can be overcome with correction of standard zero-minute concentration of blood. The results of this preliminary study on the use of NIRS for determination of D2O in plasma showed very promising as shown by a convenient and satisfy accuracy. Further study on various physiological stage of animal should be done.

  • PDF