• Title/Summary/Keyword: determining discharge

Search Result 141, Processing Time 0.022 seconds

The Dielectric Barrier micro-hollow cathode structure and its upper pD limitation in alternative current driving for flat panel light source (광원을 위한 AC구동 유전체장벽 미세공음극 구조와 상한 pd 제한조건)

  • Park K. W.;Lee T. I.;Jegal J. P.;Baik H. K.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.45-47
    • /
    • 2005
  • The Dielectric Barrier micro-hollow cathode structure and it's upper pD limitation are investigated for determining of optimum hollow cathode discharge condition. In experiment, discharge is sustained by AC diriving and investigated gas is pure Xe. From Experiment, Optimum pD range is lower than 0.72 torr.cm at pure Xe and Cu cathode.

  • PDF

System Level ESD Analysis - A Comprehensive Review II on ESD Coupling Analysis Techniques

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2033-2044
    • /
    • 2018
  • This study presents states-of-the art overview of the system level electrostatic discharge (ESD) analysis and testing. After brief description of ESD compliance standards and ESD coupling mechanisms, the study provides an in-depth review and comparison of the various techniques for the system level ESD coupling analysis using time and frequency domain techniques, full wave electromagnetic modeling and hybrid modeling. The methods used for improving system level ESD testing using troubleshooting and determining the root causes of soft failures, the optimization of ESD testing and the countermeasures to mitigate ESD problems are also discussed.

Optical Characteristics of a Flexible Back-Light Unit with Plasma Discharge Clusters

  • Goo, Gyo-Uk;Ryu, Si-Hong;Lee, Seung-Eui;Ahn, Sung-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.5
    • /
    • pp.189-192
    • /
    • 2011
  • A flexible back-light unit (FBLU) is fabricated by embedding plasma discharge clusters in a flexible polymer matrix. The brightness uniformity of an FBLU was measured for various combinations of optical sheets and compared with the simulated results for various bending angles. A gap between light sources causes distinctive integrated brightness curves which have two inflection points depending on bending angle. The brightness distribution of a simulated BLU was in good agreement with that of an actual plasma BLU except for a dark area that appeared at the center of the simulated BLU. The real and simulated BLUs both clearly showed an angle dependency caused by mirror images located between point light sources. On the basis of these results, it is suggested that these mirror-like images could be a major factor in determining the characteristics of FBLUs.

A Study on Releases Determination Scheme for a Forecasted Flood (예측홍수의 방류량 결정방안에 관한 연구)

  • Kwon, Oh-Ig;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.257-268
    • /
    • 1997
  • Reservoir operators and managers need to present a rational basis of determining releases for a flood event. This study divides a forecasted flood hydrograph by two parts on the basis of non-damaging discharge, which consists of one part con,trolled by non-damaging discharge and another controlled by using flood control storage of the reservoir. In case of using flood control storage, a new reservoir operation method. called TRF (Transformed Reservoir Flood) ROM, is suggested for the operating rules during a flood to consider the reservoir security as well as the operational efficiency. This paper presents an application of the methodology to the operation of a single multipurpose reservoir at the Taechong Dam during flood and the results analyzed.alyzed.

  • PDF

A quantification study of blood test results for dyspnea patients (호흡곤란 환자에 대한 혈액검사 결과들의 수량화 연구)

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.3
    • /
    • pp.477-485
    • /
    • 2011
  • Park et. al (2010) proposed a statistical model for determining the admission or discharge of 668 patients with a chief complaint of dyspnea by the number of 11 blood tests belonging to the corresponding discharge intervals. Since this method does not take into consideration the importance of each blood test result, its performance might not be optimally good. In this study, we employ a quantification method to evaluate the importance of those blood test results, and then provide a new statistical mode that takes the importance into consideration. The results show that the performance of this new model is a little better than that of the model by Park et. al (2010).

Effect of liquid viscosity on internal flow and spray characteristics of Y-jet atomizers (액체 점도에 따른 Y-jet 노즐 내부 유동 및 분무 특성의 변화)

  • Song, Si-Hong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4053-4061
    • /
    • 1996
  • Internal flow characteristics within Y-jet atomizers and the local drop size distribution and cross-sectional averaged drop size at the outside were investigated with the liquid and air injection pressures, mixing port length of atomizers, and the liquid properties taken as parameters. To examine the effect of the liquid viscosity, glycerin-water mixtures were used in this study. The liquid viscosity plays only a minor role in determining the internal flow pattern and the spatial distribution shape of drops, but the drop sizes themselves generally increase with increasing of the liquid viscosity. An empirical correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results; the liquid discharge coefficient strongly depends on the liquid flow area at the mixing point which is proportional to the local volumetric quality(.betha.$_{Y}$), and the volumetric quality was included in the correlation. Regardless of the value of the liquid viscosity, the compressible flow through the gas port was well represented by the polytropic expansion process(k=1.2), and the mixing point pressure could be simply correlated to the aspect ratio( $l_{m}$/ $d_{m}$) of the mixing port and the air/liquid mass flow rate ratio( $W_{g}$/ $W_{f}$) as reported in the previous study.udy.udy.y.

SiO2/styrene butadiene rubber-coated poly(ethylene terephthalate) nonwoven composite separators for safer lithium-ion batteries

  • Lee, Jung-Ran;Won, Ji-Hye;Lee, Sang-Young
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • We develop a new nonwoven composite separator for a safer lithium-ion battery, which is based on coating of silica ($SiO_2$) colloidal particles/styrene-butadiene rubber (SBR) binder to a poly(ethylene terephthalate) (PET) nonwoven support. The $SiO_2$ particles are interconnected by the SBR binder and closely packed in the nonwoven composite separator, which thus allows for the development of unusual porous structure, i.e. highly-connected interstitial voids formed between the $SiO_2$ particles. The PET nonwoven serves as a mechanical support that contributes to suppressing thermal shrinkage of the nonwoven composite separator. The $SiO_2$/SBR content in the nonwoven composite separators plays an important role in determining their separator properties. Porous structure, air permeability, and electrolyte wettability of the nonwoven composite separators, in comparison to a commercialized polyethylene (PE) separator, are elucidated as a function of the $SiO_2$/SBR content. Based on this understanding of the nonwoven composite separators, the effect of $SiO_2$/SBR content on the electrochemical performances such as self-discharge, discharge capacity, and discharge C-rate capability of cells assembled with the nonwoven composite separators is investigated.

Efficient Arc Detection and Control Method in Electro-discharge Machining (방전가공기의 효율적인 아크 검출과 제어방법)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.309-315
    • /
    • 2018
  • In this paper, propose an efficient arc detection and control method to achieve fast machining speed, improved precision and surface roughness in discharge machining, especially for carbide and hard material processing and metal processing using discharge phenomenon as energy. A single discharge waveform is divided into three sections of Td (Time-Delay), Ton (Time-on) and Toff (Time-off) and the gate control timing is simulated using the HDL language. In this paper, we analyze the effect of the gap between the electrode and the workpiece on the machining results by determining the operation of the servo mechanism by sampling the Td section through the comparator circuit. As a result of the analysis, the Td section of the formed waveform was more precisely sampled at a high speed and the results were improved when applied to the gap control between the electrode and the workpiece.

Numerical analysis of flow characteristics at the bifurcation channel by changing of discharge ratio using TELEMAC-2D (TELEMAC-2D를 적용한 개수로 분류부 유량비 변화에 의한 흐름특성 분석)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • This study investigates the flow characteristics, such as velocity distributions, size and location of recirculation zone, longitudinal flow change rates, and bifurcation discharge ratio in the bifurcation channel by TELEMAC-2D, a 2D numerical model. The numerical model is validated by previous experimental results and the numerical results are in relatively good agreement with the experimental results, such as the water surface elevation and velocity distribution in the channels. As the inertial force and moment in the main channel decrease, the bifurcation discharge ratio increases, and the relative high velocity distribution becomes wider and the reverse velocity of the main stream decreases in the branch channel. As the bifurcation discharge ratio increases, the size of the recirculation zone in the branch channel decreases and it can be more clearly calculated by determining the point where the longitudinal froude number $Fr{\approx}0$ as well as drawing the distribution of the streamline distribution.

Ideal Saturation Flow Rate and Geometric Adjustment Factors at Urban Signalized Intersection (도시부 신호교차로의 기본용량 및 기하구조 보정계수)

  • 오영태;심대영
    • Journal of Korean Society of Transportation
    • /
    • v.10 no.2
    • /
    • pp.5-24
    • /
    • 1992
  • This research presets the method of determining basic capacity of signalized intersection using the concept of ideal saturation flow rate. Vehicle discharge rates during green time were collected and studied as part of the preparation of Korean Highway Capacity Manual. From the result of this study the ideal saturation flow rate and saturation queue position were determined. In addition, based on the ideal saturation flow rate two geometric adjustment factors(lane width and grade adjustment factors) were studied. The results were presented in this paper.

  • PDF